Carescape
Catalogue number Monitor B450-LI, listed by GE Healthcare Finland OY, Finland, under Analyzer, Gas, Carbon-Dioxide, Gaseous-Phase. 29 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Guangdong (17), Jiangsu (5), Zhejiang (3). 16 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Amphenol Medical Technologies (Dongguan) Co., Ltd. | Dongguan | Guangdong | Contract manufacturer | 77 |
| Flexicare Medical (Dongguan) Ltd. | Dongguan | Guangdong | Contract manufacturer | 48 |
| Vincent Medical (Dong Guan) Manufacturing Co., Ltd. | Dong Guan | Guangdong | Contract manufacturer | 29 |
| Suzhou Jingle Polymer Medical Apparatus Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 19 |
| Sunmed AP, Ltd. | Zhuhai | Guangdong | Contract manufacturer | 18 |
| Sunmed AP, Ltd., Warehouse NO. 2 | Zhuhai | Guangdong | Contract manufacturer | 16 |
| Tylenol Medical Instruments Co., Ltd. | Zhongshan | Guangdong | Contract manufacturer | 15 |
| Forefront Medical Technology (Jiangsu) Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 14 |
| Jiangyin Sinbon Electronics Co Ltd | Jiangyin | Jiangsu | Contract manufacturer | 13 |
| Ningbo Xinwell Medical Technology Co., Ltd. | Cixi | Zhejiang | Contract manufacturer | 12 |
| Intersurgical Medical Apparatus (Changzhou) Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 12 |
| Ningbo Shengyurui Medical Appliance Co. | Ningbo | Zhejiang | Contract manufacturer | 11 |
Showing 12 of 29. All 29 manufacturers in China registered for Analyzer, Gas, Carbon-Dioxide, Gaseous-Phase
Record
| Listed by | GE Healthcare Finland OY, Finland |
|---|---|
| FDA product code | CCK |
| Device type | Analyzer, Gas, Carbon-Dioxide, Gaseous-Phase |
| Device class | Class 2 |
| Regulation | 21 CFR 868.1400 |
| Establishment | Specification developer, Repacker / relabeller, Manufacturer |
| 510(k) | K132533 |
| Record published | 2016-07-22 |
| Record revised | 2021-11-10 (version 6) |
Specifications
| MRI safety | MR Unsafe |
|---|---|
| Prescription | Prescription only |
| Label carries | manufacturing date, serial number |
| Storage | Handling environment humidity 10 to 90 % RH; Storage environment temperature -20 to 60 °C; Handling environment atmospheric pressure 70 to 106 KiloPascal; Storage environment humidity 10 to 90 % RH; Handling environment temperature 10 to 40 °C; Storage environment atmospheric pressure 50 to 106 KiloPascal |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| Monitor B450-LI | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Analyzer, Gas, Carbon-Dioxide, Gaseous-Phase | Salter Labs | 241 |
| Microstream | Oridion Medical 1987 Ltd. | 92 |
| Hudson RCI | Teleflex Medical LLC | 79 |
| Medline | Medline Industries, Inc. | 65 |
| BCI | ICU Medical, Inc | 64 |
| Curaplex | Bound Tree Medical, LLC | 60 |
| Microstream Advance | Oridion Medical 1987 Ltd. | 51 |
| Ventlab | Ventlab, LLC | 42 |
| Vital Signs | Carefusion Finland 320 Oy | 33 |
| AirLife™ | Airlife, Inc. | 32 |
| Analyzer, Gas, Carbon-Dioxide, Gaseous-Phase | Nihon Kohden Corp. | 23 |
| Curaplex | TRI-Anim Health Services, Inc. | 23 |
Showing 12 of 441. All products under Analyzer, Gas, Carbon-Dioxide, Gaseous-Phase
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K211171 | 2021-10-21 |
| K183394 | 2019-05-01 |
| K171028 | 2017-08-17 |
| K150245 | 2015-07-17 |
Recalls Naming This Product
3 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| GE Healthcare Finland OY | 510(k) number | 2018-09-04 | Class II | Software design | When multiple CARESCAPEMonitor B450 or B850 units are connected to the same network and a network overload occurs for a prolonged time, the monitors may simultaneously restart as designed. The monitor restart will not be completed until the | 59,000 units | |
| GE Healthcare Finland OY | 510(k) number | 2018-09-04 | Class II | Software design | When multiple CARESCAPEMonitor B450 or B850 units are connected to the same network and a network overload occurs for a prolonged time, the monitors may simultaneously restart as designed. The monitor restart will not be completed until the | 47,937 units | |
| GE Medical Systems, LLC | 510(k) number | 2015-05-04 | Class II | Software design | The heart rate could be calculated from pacer pulses without indication that pacemaker detection is OFF in some combinations of Bx50 monitors, a PDM, and CIC/CSCS. Then the monitor does not show the Pacer Off message and there may not be an | 110 (83 units US, 27 units OUS) | 2015-09-15 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.