LoFlo

LoFlo CO2 Sampling O2 Delivery Cannula w/Dehumidification Tubing INFANT/NEONATAL NASAL

Registry build 21.09.26
29manufacturers in China registered for this device type
20catalogue numbers in this listing
4510(k) clearances naming this product code
1recall

Who Else Makes It

Concentrated in Guangdong (17), Jiangsu (5), Zhejiang (3). 16 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code CCK
Manufacturer City Province Registered as Device types
Amphenol Medical Technologies (Dongguan) Co., Ltd. Dongguan Guangdong Contract manufacturer 77
Flexicare Medical (Dongguan) Ltd. Dongguan Guangdong Contract manufacturer 48
Vincent Medical (Dong Guan) Manufacturing Co., Ltd. Dong Guan Guangdong Contract manufacturer 29
Suzhou Jingle Polymer Medical Apparatus Co., Ltd. Suzhou Jiangsu Contract manufacturer 19
Sunmed AP, Ltd. Zhuhai Guangdong Contract manufacturer 18
Sunmed AP, Ltd., Warehouse NO. 2 Zhuhai Guangdong Contract manufacturer 16
Tylenol Medical Instruments Co., Ltd. Zhongshan Guangdong Contract manufacturer 15
Forefront Medical Technology (Jiangsu) Co., Ltd. Changzhou Jiangsu Contract manufacturer 14
Jiangyin Sinbon Electronics Co Ltd Jiangyin Jiangsu Contract manufacturer 13
Ningbo Xinwell Medical Technology Co., Ltd. Cixi Zhejiang Contract manufacturer 12
Intersurgical Medical Apparatus (Changzhou) Co., Ltd. Changzhou Jiangsu Contract manufacturer 12
Ningbo Shengyurui Medical Appliance Co. Ningbo Zhejiang Contract manufacturer 11

Showing 12 of 29. All 29 manufacturers in China registered for Analyzer, Gas, Carbon-Dioxide, Gaseous-Phase

Record

Regulatory record for LoFlo
Listed by Respironics Novametrix, LLC, United States
FDA product code CCK
Device type Analyzer, Gas, Carbon-Dioxide, Gaseous-Phase
Device class Class 2
Regulation 21 CFR 868.1400
Establishment Specification developer, Manufacturer
Record published 2021-06-09
Record revised 2025-06-23 (version 6)

Specifications

Specifications
MRI safety MR Unsafe
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date
Storage Handling environment humidity 10 to 90 % RH; Storage environment humidity 10 to 90 % RH; Handling environment temperature -40 to 70 °C; Storage environment temperature -40 to 70 °C
Packaging Pack of 10, pack of 25
UDI direct marking Exempt

Catalogue Numbers

Catalogue numbers for LoFlo
Catalogue number Size Status
1149476 In distribution
3470PEH-00 In distribution
3468PEH-00 In distribution
1149478 In distribution
3470ADH-00 In distribution
3468INH-00 In distribution
3468ADH-00 In distribution
3476-00 In distribution
1149495 In distribution
3468PED-00 In distribution
1149435 In distribution
3468ADU-00 In distribution
1149474 In distribution
1149494 In distribution
3475-00 In distribution
3470ADU-00 In distribution
3470PED-00 In distribution
3474-00 In distribution
1149484 In distribution
3468INF-00 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Analyzer, Gas, Carbon-Dioxide, Gaseous-Phase Salter Labs 241
Microstream Oridion Medical 1987 Ltd. 92
Hudson RCI Teleflex Medical LLC 79
Medline Medline Industries, Inc. 65
BCI ICU Medical, Inc 64
Curaplex Bound Tree Medical, LLC 60
Microstream Advance Oridion Medical 1987 Ltd. 51
Ventlab Ventlab, LLC 42
Vital Signs Carefusion Finland 320 Oy 33
AirLife™ Airlife, Inc. 32
Analyzer, Gas, Carbon-Dioxide, Gaseous-Phase Nihon Kohden Corp. 23
Curaplex TRI-Anim Health Services, Inc. 23

Showing 12 of 441. All products under Analyzer, Gas, Carbon-Dioxide, Gaseous-Phase

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K053174 2006-01-12
K042601 2004-11-19
K041450 2004-06-18
K030886 2003-10-07

Recalls

The FDA has not published a severity grade for these. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2006-08-11 Not classified Other Audible alarm may not sound during an alert condition 2,432 units 2012-06-12

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer