UltraviewSL
Module, MS/SS Dual Capnography
8manufacturers in China registered for this device type
1catalogue number
Who Else Makes It
Concentrated in Guangdong (7), Jiangsu (1). One is registered as a contract manufacturer, able to build to a specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Amphenol Medical Technologies (Dongguan) Co., Ltd. | Dongguan | Guangdong | Contract manufacturer | 77 |
| Shenzhen Mindray BIO-Medical Electronics Co., Ltd. | Shenzhen | Guangdong | Specification developer | 61 |
| GE Medical Systems (China) Co., Ltd. | Wuxi | Jiangsu | Contract manufacturer | 57 |
| Edan Instruments, Inc. | Shenzhen | Guangdong | Contract manufacturer | 56 |
| Orantech Inc. | Shenzhen | Guangdong | Contract manufacturer | 40 |
| Shenzhen Comen Medical Instruments Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 24 |
| Guangdong Biolight Meditech Co., Ltd. | Zhuhai | Guangdong | Manufacturer | 19 |
| Unimed Medical Supplies Inc | Shenzhen | Guangdong | Contract manufacturer | 15 |
Record
| Listed by | Spacelabs Healthcare (Washington), Inc |
|---|---|
| FDA product code | CCL |
| Device type | Analyzer, Gas, Oxygen, Gaseous-Phase |
| Device class | Class 2 |
| Regulation | 21 CFR 868.1720 |
| 510(k) | K031124 |
| Record published | 2016-09-16 |
| Record revised | 2023-10-26 (version 6) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Prescription | Prescription only |
| Label carries | manufacturing date, serial number |
| Storage | Storage environment temperature -20 to 60 °C; Storage environment humidity 0 to 95 % RH |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| Ultraview SL® | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| O2-Sensor | IT DR. Gambert Gmbh | 90 |
| Analytical Industries Inc. | Analytical Industries, Inc. | 70 |
| Oxygen Sensor | Honeywell Healthcare Solutions GmbH | 40 |
| Vital Signs™ | AirLife Finland Oy | 27 |
| MaxVenturi | Maxtec, LLC | 24 |
| Sensoronics | Sensoronics Incorporated | 15 |
| NOxBOXi | Noxbox Limited | 15 |
| Teledyne Analytical Instruments | Teledyne Analytical Instrs | 14 |
| MiniOX | Ohio Medical LLC | 12 |
| Vital Signs | Carefusion Finland 320 Oy | 10 |
| Oxygen Sensor | Maxtec, LLC | 8 |
| MAX-250 | Maxtec, LLC | 7 |
Showing 12 of 165. All products under Analyzer, Gas, Oxygen, Gaseous-Phase
Recalls Naming This Product
2 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Spacelabs Healthcare Ltd. | 510(k) number | 2011-05-12 | Not classified | Software design | Capnography Module, Model 91517, resets 20 seconds after power failure, instead of after three minutes as specified. This reset clears the RAM and the module returns to default settings. | 5883 units | 2011-12-02 |
| Spacelabs Healthcare Ltd. | 510(k) number | 2005-07-20 | Not classified | Other | The transducer used to compensate for pressure changes was mounted backwards on the printed circuit board assembly. The module will not compensate for pressure changes and CO2 readings will be inaccurate at higher altitudes. | 11 units | 2006-02-17 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.