MiniMed 780g Insulin Pump

KIT MMT-1894MD 780G US GOV 6.62U A2.0X

Registry build 21.09.26
2manufacturers in China registered for this device type
2catalogue numbers in this listing
2510(k) clearances naming this product code
3recalls on this code

Who Else Makes It

All of them in Jiangsu. One is registered as a contract manufacturer, able to build to a specification.

Chinese manufacturers registered for FDA product code NDC
Manufacturer City Province Registered as Device types
Sanmina Kunshan Jiangsu Contract manufacturer 15
Steris Sterilization Technologies (Suzhou) Ltd Suzhou Jiangsu Contract manufacturer 44

Record

Regulatory record for MiniMed 780G Insulin Pump
Listed by Medtronic Minimed, United States
FDA product code NDC
Device type Calculator, Drug Dose
Device class Class 2
Regulation 21 CFR 868.1890
Establishment Specification developer, Complaint-file establishment, Manufacturer, Exporter
510(k) K251032
Record published 2025-11-08
Record revised 2026-01-21 (version 3)

Specifications

Specifications
MRI safety MR Unsafe
Prescription Prescription only
Supplied as a kit Yes
Label carries serial number
Storage Storage environment temperature -20 to 50 °C; Handling environment humidity 5 to 95 °C

Catalogue Numbers

Catalogue numbers for MiniMed 780G Insulin Pump
Catalogue number Size Status
MMT-1894MD In distribution
MMT-1894 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Welldoc Welldoc 16
Insulia Voluntis 6
Healthfirst Cares Rx Welldoc 6
Bluestar Welldoc 6
Healthfirst Cares Welldoc 5
Conifer Connect Diabetes Welldoc 5
Welldoc Rx Welldoc 5
LivingConnected Diabetes Rx Welldoc 5
Bluestar Rx Welldoc 5
Conifer Connect Diabetes Rx Welldoc 5
inpen™ Medtronic Minimed 5
TempoSmart Welldoc 4

Showing 12 of 36. All products under Calculator, Drug Dose

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K253512 2026-01-08
K242775 2024-11-12

Recalls Naming This Product

5 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of MiniMed 780G Insulin Pump
Recalled by Identified by Initiated FDA class Root cause Reason Quantity
Medtronic Minimed 510(k) number 2026-07-13 Class II Process design Loaner insulin pumps may have been cleaned with chemically incompatible products that could damage the pump case or keypad, allow moisture ingress, and result in insulin over- or under-delivery, potentially causing hypoglycemia, hyperglycem 16
Medtronic Minimed 510(k) number 2026-07-13 Class II Process design Loaner insulin pumps may have been cleaned with chemically incompatible products that could damage the pump case or keypad, allow moisture ingress, and result in insulin over- or under-delivery, potentially causing hypoglycemia, hyperglycem 257
Medtronic Minimed 510(k) number 2026-05-27 Class II Software design A software anomaly can occur when the pump is paired with the Instinct sensor. Under certain circumstances, the pump unexpectedly stops delivering insulin and displays two error messages back-to-back: Pump Error 53 followed immediately by P 778
Medtronic Minimed 510(k) number 2026-02-13 Class II Device Design All Medtronic MiniMed infusion pumps (Paradigm series, 600 series, and BLE 700 series) were found to be affected by unintended over- and under-delivery of insulin when the pump is elevated or lowered relative to the infusion site, respectiv 453,144
Medtronic Minimed 510(k) number 2026-01-30 Class II Software change control Three software defects (Pump Error 53, BG check, and Critical Pump Error (Open Book Image)) that occurred as a result of software updates (versions 6.60, 6.61, and 6.62), which could result in a risk of hypoglycemia or hyperglycemia due to 26,851 pumps

Recalls

3 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity
2026-06-16 Class II Software design For MiniMed Go app version 1.0.0 and 1.1.0, when the Set day and night is turned OFF and missed dose or Correct high glucose alerts are enabled, the associated alerts will not be triggered during the nighttime. This could result in mi 3,465
2025-11-13 Class II Software Design Change When app is uninstalled and reinstalled, insulin pen software issue causes Choose Notification Style Screen to not show during setup so users can’t choose to allow notifications to override phone settings when on mute/Do Not Disturb, and pr 8251
2025-06-16 Class II Under Investigation by firm Medtronic MiniMed, Inc. is recalling InPen App for iOS and Android users due to software design errors that could lead to a missed short-acting insulin dose reminder and a recommendation to correct a high glucose value. It does not impact i 6816

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer