MiniMed 780g Insulin Pump
KIT MMT-1894MD 780G US GOV 6.62U A2.0X
Who Else Makes It
All of them in Jiangsu. One is registered as a contract manufacturer, able to build to a specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Sanmina | Kunshan | Jiangsu | Contract manufacturer | 15 |
| Steris Sterilization Technologies (Suzhou) Ltd | Suzhou | Jiangsu | Contract manufacturer | 44 |
Record
| Listed by | Medtronic Minimed, United States |
|---|---|
| FDA product code | NDC |
| Device type | Calculator, Drug Dose |
| Device class | Class 2 |
| Regulation | 21 CFR 868.1890 |
| Establishment | Specification developer, Complaint-file establishment, Manufacturer, Exporter |
| 510(k) | K251032 |
| Record published | 2025-11-08 |
| Record revised | 2026-01-21 (version 3) |
Specifications
| MRI safety | MR Unsafe |
|---|---|
| Prescription | Prescription only |
| Supplied as a kit | Yes |
| Label carries | serial number |
| Storage | Storage environment temperature -20 to 50 °C; Handling environment humidity 5 to 95 °C |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| MMT-1894MD | In distribution | |
| MMT-1894 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Welldoc | Welldoc | 16 |
| Insulia | Voluntis | 6 |
| Healthfirst Cares Rx | Welldoc | 6 |
| Bluestar | Welldoc | 6 |
| Healthfirst Cares | Welldoc | 5 |
| Conifer Connect Diabetes | Welldoc | 5 |
| Welldoc Rx | Welldoc | 5 |
| LivingConnected Diabetes Rx | Welldoc | 5 |
| Bluestar Rx | Welldoc | 5 |
| Conifer Connect Diabetes Rx | Welldoc | 5 |
| inpen™ | Medtronic Minimed | 5 |
| TempoSmart | Welldoc | 4 |
Showing 12 of 36. All products under Calculator, Drug Dose
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K253512 | 2026-01-08 |
| K242775 | 2024-11-12 |
Recalls Naming This Product
5 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|---|---|
| Medtronic Minimed | 510(k) number | 2026-07-13 | Class II | Process design | Loaner insulin pumps may have been cleaned with chemically incompatible products that could damage the pump case or keypad, allow moisture ingress, and result in insulin over- or under-delivery, potentially causing hypoglycemia, hyperglycem | 16 |
| Medtronic Minimed | 510(k) number | 2026-07-13 | Class II | Process design | Loaner insulin pumps may have been cleaned with chemically incompatible products that could damage the pump case or keypad, allow moisture ingress, and result in insulin over- or under-delivery, potentially causing hypoglycemia, hyperglycem | 257 |
| Medtronic Minimed | 510(k) number | 2026-05-27 | Class II | Software design | A software anomaly can occur when the pump is paired with the Instinct sensor. Under certain circumstances, the pump unexpectedly stops delivering insulin and displays two error messages back-to-back: Pump Error 53 followed immediately by P | 778 |
| Medtronic Minimed | 510(k) number | 2026-02-13 | Class II | Device Design | All Medtronic MiniMed infusion pumps (Paradigm series, 600 series, and BLE 700 series) were found to be affected by unintended over- and under-delivery of insulin when the pump is elevated or lowered relative to the infusion site, respectiv | 453,144 |
| Medtronic Minimed | 510(k) number | 2026-01-30 | Class II | Software change control | Three software defects (Pump Error 53, BG check, and Critical Pump Error (Open Book Image)) that occurred as a result of software updates (versions 6.60, 6.61, and 6.62), which could result in a risk of hypoglycemia or hyperglycemia due to | 26,851 pumps |
Recalls
3 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|
| 2026-06-16 | Class II | Software design | For MiniMed Go app version 1.0.0 and 1.1.0, when the Set day and night is turned OFF and missed dose or Correct high glucose alerts are enabled, the associated alerts will not be triggered during the nighttime. This could result in mi | 3,465 |
| 2025-11-13 | Class II | Software Design Change | When app is uninstalled and reinstalled, insulin pen software issue causes Choose Notification Style Screen to not show during setup so users can’t choose to allow notifications to override phone settings when on mute/Do Not Disturb, and pr | 8251 |
| 2025-06-16 | Class II | Under Investigation by firm | Medtronic MiniMed, Inc. is recalling InPen App for iOS and Android users due to software design errors that could lead to a missed short-acting insulin dose reminder and a recommendation to correct a high glucose value. It does not impact i | 6816 |