Pyxis Pro MedStation

Pyxis Pro MedStation Dispensing System cabinet, table and tray, anesthesia

Registry build 21.09.26
22manufacturers in China registered for this device type
180catalogue numbers in this listing
40recalls on this code

Who Else Makes It

Concentrated in Guangdong (5), Jiangsu (5), Hebei (4). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code BRY
Manufacturer City Province Registered as Device types
Hubei Yinkang Medical Equipment Co., Ltd. Xiaogan Hubei Contract manufacturer 8
Ningbo Hecai Medical Equipment Co., Ltd. Ningbo Zhejiang Contract manufacturer 8
Lakong Medical Devices Co., Ltd. Dongguan Guangdong Remanufacturer 39
Jiangsu Saikang Medical Equipment Co., Ltd. Zhangjiagang Jiangsu Contract manufacturer 34
China (Shenyang) MED-Land IMP/EXP Corp., Ltd. Shanghai Shanghai Exporter 32
Shanghai NO. 2 Medical College Duhang Medical Equipment Factory Shanghai Shanghai Contract manufacturer 32
Jiangsu Rooe Medical Technology Co., Ltd. Zhangjiagang Jiangsu Manufacturer 31
Better Medical Technology Co., Ltd. Foshan Guangdong Manufacturer 24
Hefei MT Medical Co., Ltd. Hefei Anhui Manufacturer 23
Jiangsu Keling Medical Appliances Co., Ltd. Yangzhou Jiangsu Contract manufacturer 23
Jiangsu Sintang Health&Technology Co., Ltd. Yancheng Jiangsu Manufacturer 21
Shenzhen WAP-Health Technology Co., Ltd. Shenzhen Guangdong Repacker / relabeller 16

Showing 12 of 22. All 22 manufacturers in China registered for Cabinet, Table And Tray, Anesthesia

Record

Regulatory record for Pyxis Pro MedStation
Listed by CareFusion 303, Inc, United States
FDA product code BRY
Device type Cabinet, Table And Tray, Anesthesia
Device class Class 1
Regulation 21 CFR 868.6100
Establishment Specification developer, Complaint-file establishment, Manufacturer
Premarket notification Exempt
Record published 2025-06-05
Record revised 2026-06-11 (version 2)

Specifications

Specifications
MRI safety MR Unsafe
Label carries lot or batch number, serial number
Storage Storage environment temperature -4 to 140 °F; Special storage condition: Keep dry; Storage environment humidity 15 to 85 % RH; Special storage condition: Special Storage Conditions (see IFU)
Distribution end date 2026-05-22

Catalogue Numbers

Catalogue numbers for Pyxis Pro MedStation
Catalogue number Size Status
177-83 In distribution
177-55 In distribution
177-20 In distribution
177-74 In distribution
177-184 In distribution
177-78 In distribution
177-54 In distribution
177-148 In distribution
177-146 In distribution
177-49 In distribution
177-87 In distribution
177-125 In distribution
177-137 In distribution
177-73 In distribution
177-39 In distribution
177-158 In distribution
177-67 In distribution
177-34 In distribution
177-89 In distribution
177-35 In distribution
177-112 In distribution
SW-MS-ES-PRO-V48 In distribution
177-169 In distribution
177-147 In distribution
177-155 In distribution
177-43 In distribution
177-178 In distribution
177-171 In distribution
177-92 In distribution
177-28 In distribution
177-46 In distribution
177-24 In distribution
177-182 In distribution
177-162 In distribution
177-152 In distribution
177-58 In distribution
177-159 In distribution
177-91 In distribution
177-86 In distribution
177-22 In distribution
177-124 In distribution
177-177 In distribution
177-172 In distribution
177-128 In distribution
177-76 In distribution
177-174 In distribution
177-103 In distribution
177-132 In distribution
177-93 In distribution
177-38 In distribution
177-110 In distribution
177-32 In distribution
177-96 In distribution
177-41 In distribution
177-153 In distribution
177-185 In distribution
177-45 In distribution
177-119 In distribution
177-94 In distribution
177-14 In distribution
177-164 In distribution
177-151 In distribution
177-53 In distribution
177-115 In distribution
177-18 In distribution
177-98 In distribution
177-144 In distribution
177-69 In distribution
177-68 In distribution
177-102 In distribution
177-44 In distribution
177-48 In distribution
177-29 In distribution
177-82 In distribution
177-122 In distribution
177-70 In distribution
177-66 In distribution
177-105 In distribution
177-101 In distribution
177-138 In distribution
177-90 In distribution
177-42 In distribution
177-142 In distribution
177-64 In distribution
177-154 In distribution
177-129 In distribution
177-113 In distribution
177-75 In distribution
177-114 In distribution
177-131 In distribution
177-123 In distribution
177-16 In distribution
177-127 In distribution
177-109 In distribution
177-157 In distribution
177-84 In distribution
177-30 In distribution
177-106 In distribution
177-63 In distribution
177-71 In distribution
177-36 In distribution
177-255 In distribution
177-163 In distribution
1149-00 In distribution
177-111 In distribution
177-17 In distribution
177-31 In distribution
177-108 In distribution
177-79 In distribution
177-100 In distribution
177-168 In distribution
177-77 In distribution
177-50 In distribution
177-120 In distribution
1152-00 In distribution
177-130 In distribution
177-88 In distribution
177-183 In distribution
177-136 In distribution
177-140 In distribution
177-176 In distribution
177-26 In distribution
177-126 In distribution
177-150 In distribution
177-61 In distribution
177-166 In distribution
177-167 In distribution
177-135 In distribution
177-116 In distribution
177-107 In distribution
177-161 In distribution
177-23 In distribution
177-37 In distribution
177-95 In distribution
177-117 In distribution
177-60 In distribution
177-57 In distribution
177-51 In distribution
177-13 In distribution
177-175 In distribution
177-139 In distribution
177-27 In distribution
177-85 In distribution
177-149 In distribution
177-156 In distribution
177-143 In distribution
177-165 In distribution
177-179 In distribution
177-47 In distribution
177-15 In distribution
177-56 In distribution
177-118 In distribution
177-19 In distribution
177-81 In distribution
177-33 In distribution
177-52 In distribution
177-173 In distribution
177-12 In distribution
177-170 In distribution
177-72 In distribution
177-134 In distribution
177-80 In distribution
177-145 In distribution
177-40 In distribution
177-97 In distribution
177-59 In distribution
177-121 In distribution
177-62 In distribution
177-160 In distribution
177-181 In distribution
177-180 In distribution
177-99 In distribution
177-21 In distribution
177-104 In distribution
1155-00 In distribution
177-65 In distribution
177-25 In distribution
177-133 In distribution
177-141 In distribution
177-216 Withdrawn

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
BD Pyxis CareFusion 303, Inc 33
Starsys® Intermetro Industries Corp 6
Pyxis CareFusion 303, Inc 6
Hospital Trolley Resmed PTY Ltd. 4
Flexline® Intermetro Industries Corp 3
laryngo-sheath General Hospital Supply Corp. 3
ResMed Resmed PTY Ltd. 2
Homecare Resmed PTY Ltd. 2
APA IP Shield™ VL Venner Medical (Singapore) PTE Ltd 1
Pyxis MedStation CareFusion 303, Inc 1
XT Anesthesia Workstation (AWS) Omnicell, Inc. 1
IntelliGuard® Anesthesia IntelliGuard Group, LLC 1

Showing 12 of 15. All products under Cabinet, Table And Tray, Anesthesia

Recalls Naming This Product

2 recalls name this product by its own identifiers, the UDI on its label.

Recalls naming the identifiers of Pyxis Pro MedStation
Recalled by Identified by Initiated FDA class Root cause Reason Quantity
CareFusion 303, Inc UDI-DI 2025-09-30 Class II Under Investigation by firm Potential fluid ingress of anesthesia station or med station may result in smoke, system downtime and/or fire. 32 units
CareFusion 303, Inc UDI-DI 2025-09-30 Class II Under Investigation by firm Potential fluid ingress of anesthesia station or med station may result in smoke, system downtime and/or fire. 27 units

Recalls

37 of these are Class II. Class II means a temporary or reversible health consequence. Class III is unlikely to cause harm at all → typically a labelling or documentation fault. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity
2026-04-30 Class II Component design/selection Fingerprint scanner may overheat to a temperature to cause 1st degree burn. 465 units
2026-04-30 Class II Component design/selection Fingerprint scanner may overheat to a temperature to cause 1st degree burn. 1 unit
2026-04-30 Class II Component design/selection Fingerprint scanner may overheat to a temperature to cause 1st degree burn. 114 units
2026-04-30 Class II Component design/selection Fingerprint scanner may overheat to a temperature to cause 1st degree burn. 1 unit
2026-04-30 Class II Component design/selection Fingerprint scanner may overheat to a temperature to cause 1st degree burn. 607 units
2026-04-30 Class II Component design/selection Fingerprint scanner may overheat to a temperature to cause 1st degree burn. 709 units
2026-04-30 Class II Component design/selection Fingerprint scanner may overheat to a temperature to cause 1st degree burn. 4,579 units
2026-04-30 Class II Component design/selection Fingerprint scanner may overheat to a temperature to cause 1st degree burn. 15,933
2025-12-03 Class II Under Investigation by firm Due a software issue that may result in equipment not receiving timely updates of patient, medication, or related information from enterprise systems. 2,079 systems
2025-11-20 Class II Device Design Automated Dispensing Cabinets (ADC) received a Half Height CUBIE drawer firmware update, which caused a Cubie Insert event which prompts software to generate a duplicate address, which causes an error and the drawer to fail, which may lead 53669
2025-09-30 Class II Under Investigation by firm Potential fluid ingress of anesthesia station or med station may result in smoke, system downtime and/or fire. 443 units
2025-09-30 Class II Under Investigation by firm Potential fluid ingress of anesthesia station or med station may result in smoke, system downtime and/or fire. 2,755 units
2025-09-30 Class II Under Investigation by firm Potential fluid ingress of anesthesia station or med station may result in smoke, system downtime and/or fire. 8,262 units
2025-07-10 Class III Use error Reports of delayed access to medication in automated dispensing cabinets because of the override/Add Item workflow. 6076
2025-05-08 Class II Under Investigation by firm Antivirus software was not consistently installed on impacted devices during the implementation process. 8353 devices (6738 U.S. and 1615 O.U.S.)
2025-05-08 Class II Software Design Change During automated dispensing cabinet upgrade/installation/reimaging, component manager was left in installed mode, and if a Microsoft patch is then installed this may lead to an error preventing user access to the dispensing software applica 6,332
2025-03-11 Class II Software design Users trying to restock a single bin location of an automated dispensing cabinet, during pocket exchange restocking workflow, may experience a software issue that results in 2 destock transactions and 2 stock transactions, which results in 7,357
2025-03-11 Class II Device Design Due to a software issue, when attempting to restock the automated dispensing cabinet, user have received the banner message “Stocking window has passed, or item has been removed from purchase order. Please contact Pharmacy for assistance”. 404 systems
2025-03-11 Class II Software design Due to a software bug, automated dispensing cabinet is unable to calculate countback discrepancies during the issue process, which causes incorrect transaction quantity to be recorded. This bug can also result in the CUBIE opening more time 7357
2025-02-06 Class II Software design Sync timeout may occur between the server and automated dispensing device, due to a server software error which may occur if syncing a large amount of data that takes excessive time, which may cause the dispensing devices to become disconne 727
2025-01-23 Class II Nonconforming Material/Component Due to fingerprint scanner failing resulting in the scanner heating up. 229 MedFlex and 3,154 spare Bio-ID spare parts
2025-01-10 Class II Labeling design Automated dispensing device labeling is being updated to strengthen labeling around manual access to medications to address the risk of potential delays in retrieving contents/ accessing medications that may result from power loss or potent 1521
2025-01-08 Class II Under Investigation by firm Labeling update to include a contraindication statement against the use of medicine cabinets in procedure and operating rooms.
2025-01-08 Class II Software design Software issues could potentially result in: 1) delays in accessing dispensing software application, 2) wrong therapy (dose, item, timing, etc.), or 3) unauthorized access and/or compliance related issues 137,741 total
2025-01-08 Class II Under Investigation by firm Labeling update to include a contraindication statement against the use of medicine cabinets in procedure and operating rooms.
2025-01-08 Class II Under Investigation by firm Labeling update to include a contraindication statement against the use of medicine cabinets in procedure and operating rooms.
2025-01-08 Class II Labeling design Labeling is insufficient regarding delays in access to medication. The firm is strengthening the label as an additional risk mitigation. 193067
2025-01-08 Class II Under Investigation by firm Labeling update to include a contraindication statement against the use of medicine cabinets in procedure and operating rooms. 6,075 units
2024-11-14 Class II Software design Due to a software issue, automated dispensing cabinet devices may open the wrong cubie pocket or position, which can lead to: 1) Unintended and incorrect medication removal, or 2) Potential for a different medication (medication pulled in e 218
2024-11-14 Class II Software design Due to a software issue, automated dispensing cabinet devices may open the wrong cubie pocket or position, which can lead to: 1) Unintended and incorrect medication removal, or 2) Potential for a different medication (medication pulled in e 40,763
2024-11-14 Class II Software design Due to a software issue, automated dispensing cabinet devices may open the wrong cubie pocket or position, which can lead to: 1) Unintended and incorrect medication removal, or 2) Potential for a different medication (medication pulled in e 98,526
2024-07-09 Class II Software design Due to software issue, there is a potential when a restock label is printed for a medication stored in a non-CUBIE location, that the incorrect bin for the medication is printed on the label.
2024-07-09 Class II Software design Due to software issue, there is a potential when a restock label is printed for a medication stored in a non-CUBIE location, that the incorrect bin for the medication is printed on the label. 3 units
2024-06-24 Class II Under Investigation by firm Due to software issue, there is a potential when a restock label is printed for a medication stored in automated dispensing cabinets, that the incorrect bin for the medication is printed on the label. 3 units
2024-06-24 Class II Under Investigation by firm Due to software issue, there is a potential when a restock label is printed for a medication stored in automated dispensing cabinets, that the incorrect bin for the medication is printed on the label. 1 unit
2024-06-24 Class II Under Investigation by firm Due to software issue, there is a potential when a restock label is printed for a medication stored in automated dispensing cabinets, that the incorrect bin for the medication is printed on the label. 16 units
2024-06-24 Class II Under Investigation by firm Due to software issue, there is a potential when a restock label is printed for a medication stored in automated dispensing cabinets, that the incorrect bin for the medication is printed on the label. 5 units
2024-06-24 Class II Under Investigation by firm Due to software issue, there is a potential when a restock label is printed for a medication stored in automated dispensing cabinets, that the incorrect bin for the medication is printed on the label. 84 units

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer