Portrait SBT01
Sensor Battery Device Assembly
8manufacturers in China registered for this device type
1catalogue number
Who Else Makes It
Concentrated in Guangdong (5), Jiangsu (1), Hebei (1). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Amphenol Medical Technologies (Dongguan) Co., Ltd. | Dongguan | Guangdong | Contract manufacturer | 77 |
| Wuhan Strong Electronics | Wuhan | Hubei | Contract manufacturer | 6 |
| Ryder Electronics (Shenzhen) Ltd. | Shenzhen | Guangdong | Contract manufacturer | 5 |
| Dongguan Smart Manufacturing Partner Electronic Company Limited | Dongguan | Guangdong | Contract manufacturer | 1 |
| GE Medical Systems (China) Co., Ltd. | Wuxi | Jiangsu | Contract manufacturer | 57 |
| Edan Instruments, Inc. | Shenzhen | Guangdong | Contract manufacturer | 56 |
| Contec Medical Systems Co., Ltd. | Qinhuangdao | Hebei | Manufacturer | 22 |
| Guangdong Biolight Meditech Co., Ltd. | Zhuhai | Guangdong | Manufacturer | 19 |
Record
| Listed by | GE Healthcare Finland OY, Finland |
|---|---|
| FDA product code | BZQ |
| Device type | Monitor, Breathing Frequency |
| Device class | Class 2 |
| Regulation | 21 CFR 868.2375 |
| Establishment | Specification developer, Repacker / relabeller, Manufacturer |
| 510(k) | K230626 |
| Record published | 2023-09-12 |
Specifications
| MRI safety | MR Unsafe |
|---|---|
| Prescription | Prescription only |
| Label carries | serial number |
| Storage | Storage environment atmospheric pressure 50 to 106 KiloPascal; Storage environment humidity 5 to 95 % RH; Storage environment temperature -20 to 40 °C |
| Packaging | Pack of 2 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| SBT01 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Perfect Fit | Dymedix Diagnostics Inc | 189 |
| Monitor, Breathing Frequency | ConMed Corporation | 106 |
| Monitor, Breathing Frequency | Salter Labs | 52 |
| Conmed | ConMed Corporation | 46 |
| Cadwell | Cadwell Industries, Inc. | 44 |
| Sensor | Respironics Inc. | 42 |
| ThermiSense | Salter Labs | 33 |
| SnuggleFit | Dymedix Diagnostics Inc | 23 |
| Braebon Cable for Disposable RIP | Braebon Medical Corp. | 5 |
| PneumoTherm | Salter Labs | 4 |
| BiNAPS | Salter Labs | 4 |
| SleepmatePiezo Crystal Sensor & Band, Adult/Ped, Double Buckle, Alice | Ambu A/S | 4 |
Showing 12 of 248. All products under Monitor, Breathing Frequency
Recalls Naming This Product
1 recall names this product by its own identifier, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|---|---|
| GE Medical Systems Information Technologies, Inc. | 510(k) number | 2026-07-20 | Class II | Device Design | Software issue may result in a loss of patient monitoring at the Hub and Central Viewer. In addition, all alarm settings could be reset to factory defaults following the update and will not follow the alarm settings previously configured fo | 15 units |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.