CuffTrek
CuffTrek is intended to measure and regulate intracuff pressure in endotracheal tubes, tracheotomy tubes and laryngeal mask airways. The FDA filing describes it for single-patient use from…
CuffTrek is intended to measure and regulate intracuff pressure in endotracheal tubes, tracheotomy tubes and laryngeal mask airways. The FDA filing describes it for single-patient use from pediatric to adult patients under medical supervision.
The filing describes continuous pressure measurement inside an endotracheal tube balloon while it is in use. Pressure is displayed on a digital screen.
Pressure Monitoring
The indications specify use under medical supervision in settings where a patient may be intubated.
Who Else Makes It
Concentrated in Shanghai (2), Jiangsu (1), Tianjin (1). 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Conod Medical Co., Limited | Changshu | Jiangsu | Contract manufacturer | 48 |
| Quasar Electronics Technology (Dongguan) Co., Ltd. | Dongguan | Guangdong | Contract manufacturer | 2 |
| TDG Technology Co., Ltd. | Jiaxing | Zhejiang | Contract manufacturer | 1 |
| Tianjin Medis Medical Device Co., Ltd. | Tianjin | Tianjin | Contract manufacturer | 5 |
| Medtronic (Shanghai) Medical Technology Co., Ltd. | Min Hang District | Shanghai | Specification developer | 4 |
| Shanghai Longmann Tech Co., Ltd. | Shanghai | Shanghai | Manufacturer | 1 |
Record
| Listed by | Shanghai Longmann Tech Co., Ltd., China |
|---|---|
| FDA product code | BSK |
| Device type | Cuff, Tracheal Tube, Inflatable |
| Device class | Class 2 |
| Regulation | 21 CFR 868.5750 |
| Establishment | Manufacturer, Exporter |
| 510(k) | K242642 |
| Record published | 2026-01-23 |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date, manufacturing date, serial number |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| LG-1 | In distribution | |
| LG-1 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| CuffGuard | Idmed Corp. | 12 |
| Cuff, Tracheal Tube, Inflatable | VBM Medizintechnik Gmbh | 6 |
| Rusch | Teleflex Medical LLC | 5 |
| Cuff, Tracheal Tube, Inflatable | Nuvasive, Inc. | 4 |
| Tracoe® technic | Tracoe Medical Gmbh | 4 |
| Medis | Tianjin Medis Medical Device Co., Ltd. | 3 |
| AincA® | Anesthesia Associates, Inc. | 2 |
| Puritan Bennett | Covidien LP | 2 |
| Posey | Posey Products, LLC | 2 |
| Medline | Medline Industries, Inc. | 2 |
| Cuffix | Biovo Technologies, Ltd. | 2 |
| Ambu A/S | VBM Medizintechnik Gmbh | 2 |
Showing 12 of 29. All products under Cuff, Tracheal Tube, Inflatable
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K242642 | 2025-03-07 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.