Sonoblock

The FDA filing identifies SonoBlock and SonoBlock II as single-use anesthesia conduction nerve-block needles for peripheral nerve blocks under ultrasound guidance. The needles puncture…

Registry build 21.09.26

The FDA filing identifies SonoBlock and SonoBlock II as single-use anesthesia conduction nerve-block needles for peripheral nerve blocks under ultrasound guidance.

The needles puncture tissue to gain entry and inject local anesthetic for regional anesthesia. The filing says they are not intended for radiofrequency ablation or other ablation procedures.

Listed Item

SonoBlock 20G (0,90) x 120mm with injection tube

Device-Family Note

The filing also distinguishes SonoBlock II as a directly injection-moulded option in comparison with the glued predicate design.

9manufacturers in China registered for this device type
70catalogue numbers in this listing
13510(k) clearances naming this product code
1recall

Who Else Makes It

Concentrated in Zhejiang (5), Shanghai (2), Jiangsu (1). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code BSP
Manufacturer City Province Registered as Device types
Zhejiang Runqiang Medical Instruments Co., Ltd. Jiaxing Zhejiang Contract manufacturer 9
Ningbo Linstant Polymer Materials Co., Ltd. Ningbo Zhejiang Contract manufacturer 1
Jiangsu NEW Pentastar Medical Products Co., Ltd. Changzhou Jiangsu Exporter 146
Hangzhou Fushan Medical Appliance Co., Ltd. Hangzhou Zhejiang Contract manufacturer 44
Zhejiang Medicines & Health Products I/ E Co., Ltd. Hangzhou Zhejiang Exporter 41
Zhejiang Kindly Medical Devices Co., Ltd. Wenzhou Zhejiang Contract manufacturer 16
Shanghai Mekon Medical Devices Co., Ltd. Shanghai Shanghai Exporter 11
Tianjin Hanaco Medical Co., Ltd. Tianjin Tianjin Contract manufacturer 3
Shanghai SA Medical & Plastic Instruments Co., Ltd. Shanghai Shanghai Manufacturer 1

Record

Regulatory record for Sonoblock
Listed by Pajunk Gmbh Medizintechnologie, Germany
FDA product code BSP
Device type Needle, Conduction, Anesthetic (W/Wo Introducer)
Device class Class 2
Regulation 21 CFR 868.5150
Establishment Contract manufacturer, Specification developer, Repacker / relabeller, Private-label distributor, Complaint-file establishment, Manufacturer
510(k) K241954
Record published 2021-04-02
Record revised 2025-12-01 (version 7)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Latex Labelled latex-free
Label carries lot or batch number, expiry date, manufacturing date
Storage Storage environment temperature 10 to 30 °C; Storage environment humidity 10 to 65 % RH
Packaging Pack of 10
Sizes Length 40 to 150 mm; outer diameter 0.7 to 0.9 mm; needle gauge 21 to 25 G
Distribution end date 2026-07-17

Catalogue Numbers

Catalogue numbers for Sonoblock
Catalogue number Size Per pack Status
001180-31G In distribution
001180-71 In distribution
001180-81 Needle Gauge 25.0 G In distribution
001180-77 In distribution
001181-71 In distribution
001180-74 In distribution
001181-74 In distribution
001181-77 In distribution
001280-72 10 Withdrawn
001180-31G 10 Withdrawn
001265-70 Length 40.0 mm 10 Withdrawn
001180-71 10 Withdrawn
001180-31G 10 Withdrawn
001267-70 Outer Diameter 0.7 mm 10 Withdrawn
001180-30G 10 Withdrawn
001267-72 Length 120.0 mm 10 Withdrawn
001265-74 Outer Diameter 0.7 mm 10 Withdrawn
001260-71 10 Withdrawn
001181-93 Needle Gauge 22.0 G Withdrawn
001260-77 10 Withdrawn
001181-74 10 Withdrawn
001180-85 Length 50.0 mm Withdrawn
001180-30G 10 Withdrawn
001180-71 10 Withdrawn
001180-77 10 Withdrawn
001181-78 Needle Gauge 24.0 G Withdrawn
001180-70 10 Withdrawn
001180-31J 10 Withdrawn
001265-76 10 Withdrawn
001267-74 Outer Diameter 0.7 mm 10 Withdrawn
001180-72 10 Withdrawn
001180-31H 10 Withdrawn
001180-31H 10 Withdrawn
001280-71 10 Withdrawn
001181-88 Length 80.0 mm Withdrawn
001280-95 10 Withdrawn
001281-74 10 Withdrawn
001180-74 10 Withdrawn
001181-74 10 Withdrawn
001181-77 10 Withdrawn
001281-70 10 Withdrawn
001267-77 Length 100.0 mm 10 Withdrawn
001260-74 10 Withdrawn
001280-74 10 Withdrawn
001281-77 10 Withdrawn
001265-71 Outer Diameter 0.7 mm 10 Withdrawn
001181-70 10 Withdrawn
001281-71 10 Withdrawn
001181-72 10 Withdrawn
001267-76 Outer Diameter 0.9 mm 10 Withdrawn
001265-72 Length 120.0 mm 10 Withdrawn
001281-95 10 Withdrawn
001265-77 Outer Diameter 0.8 mm 10 Withdrawn
001180-78 Length 40.0 mm Withdrawn
001260-89 10 Withdrawn
001281-72 10 Withdrawn
001180-70 10 Withdrawn
001280-77 10 Withdrawn
001181-70 10 Withdrawn
001181-71 10 Withdrawn
001181-71 10 Withdrawn
001181-81 Needle Gauge 25.0 G Withdrawn
001181-94 Length 70.0 mm Withdrawn
001267-71 Length 80.0 mm 10 Withdrawn
001181-72 10 Withdrawn
001180-72 10 Withdrawn
001180-74 10 Withdrawn
001181-77 10 Withdrawn
001180-31J 10 Withdrawn
001180-77 10 Withdrawn

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Halyard Avanos Medical, Inc. 386
Sprotte® Pajunk Gmbh Medizintechnologie 273
Avanos Avanos Medical, Inc. 264
Epimed Epimed International, Inc. 131
Phoenix DR. Japan Co., Ltd. 128
Tuohy Pajunk Gmbh Medizintechnologie 128
Lccs Lccs Products Limited 121
Arrow Teleflex Medical LLC 104
Reli Myco Medical Supplies, Inc. 86
Temena Temena GmbH 67
Sprotte® NRFit Pajunk Gmbh Medizintechnologie 63
Spinal Needle Hakko Co., Ltd. 51

Showing 12 of 149. All products under Needle, Conduction, Anesthetic (W/Wo Introducer)

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K243690 2025-07-01
K243682 2025-06-27
K250774 2025-06-25
K243525 2025-03-24
K241953 2024-11-22
K241954 2024-09-11
K170435 2017-07-12
K160297 2016-10-28
K160296 2016-10-27
K160295 2016-10-27
K160294 2016-10-21
K111374 2011-08-29
K063350 2008-02-01

Recalls

1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity
2019-08-30 Class II Process control Problem with packaging sealing process which affects sterility. 40,475 devices

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer