Rusch

Flexi-slip Endotracheal Tube Stylet with Soft Distal Tip

Registry build 21.09.26
34manufacturers in China registered for this device type
6catalogue numbers in this listing
4recalls on this code

Who Else Makes It

Concentrated in Zhejiang (10), Jiangsu (9), Guangdong (8). 11 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code BSR
Manufacturer City Province Registered as Device types
Flexicare Medical (Dongguan) Ltd. Dongguan Guangdong Contract manufacturer 48
Well Lead Medical Co., Ltd. Guangzhou Guangdong Contract manufacturer 46
Hangzhou Fushan Medical Appliance Co., Ltd. Hangzhou Zhejiang Contract manufacturer 44
Modern Medical Equipment Manufacturing Ltd. Heng Li, Dongguan Guangdong Contract manufacturer 26
Modern Medical Equipment Manufacturing (Qing Yuan) Ltd Qing Yuan Guangdong Contract manufacturer 26
Hitec Medical Co., Ltd. Shanghai Shanghai Contract manufacturer 17
Forefront Medical Technology (Jiangsu) Co., Ltd. Changzhou Jiangsu Contract manufacturer 14
Hangzhou Jinlin Medical Appliances Co., Ltd. Hangzhou Zhejiang Contract manufacturer 11
Shenzhen Insighters Medical Technology Co., Ltd. Shenzhen Guangdong Contract manufacturer 10
Hangzhou Formed Medical Devices Co., Ltd. Hangzhou Zhejiang Contract manufacturer 9
Tianjin Medis Medical Device Co., Ltd. Tianjin Tianjin Contract manufacturer 5
Boen Healthcare Co., Ltd. Suzhou Jiangsu Specification developer 263

Showing 12 of 34. All 34 manufacturers in China registered for Stylet, Tracheal Tube

Record

Regulatory record for Rusch
Listed by Teleflex Medical LLC, United States
FDA product code BSR
Device type Stylet, Tracheal Tube
Device class Class 1
Regulation 21 CFR 868.5790
Establishment Specification developer, Complaint-file establishment, Manufacturer
Premarket notification Exempt
Record published 2018-09-15
Record revised 2025-03-18 (version 5)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Latex Labelled latex-free
Label carries lot or batch number, expiry date, manufacturing date
Packaging Box of 25, case of 8, box of 20, case of 5

Catalogue Numbers

Catalogue numbers for Rusch
Catalogue number Size Status
IPN044594 In distribution
IPN040672 In distribution
IPN045168 In distribution
IPN044648 In distribution
IPN044647 In distribution
IPN044649 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
SunMed SunMed Group Holdings, LLC 22
Stylet, Tracheal Tube VBM Medizintechnik Gmbh 17
Hudson RCI Teleflex Medical LLC 16
SourceMark Sourcemark, LLC. 13
Intubating Stylet Well Lead Medical Co., Ltd. 11
AincA® Anesthesia Associates, Inc. 8
Medline Medline Industries, Inc. 8
Sheridan Teleflex Medical LLC 7
Cardinal Health Cardinal Health 200, LLC 4
Anesthesia Sunset Healthcare Solutions, Inc. 4
Vital Signs™ Airlife, Inc. 4
Portex ICU Medical, Inc 4

Showing 12 of 86. All products under Stylet, Tracheal Tube

Recalls

3 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2017-05-11 Class II Labeling mix-ups Product size listed on the labeling is incorrect. 21,690 eaches
2015-08-24 Class II Unknown/Undetermined by firm Due to reports of the plastic coating of the stylet splitting and/or breaking off of the stylet. 233,641 units 2017-09-25
2015-08-24 Class II Unknown/Undetermined by firm Due to reports of the plastic coating of the stylet splitting and/or breaking off of the stylet. 233,641 units 2017-09-25
2011-12-02 Not classified Pending Complaints of difficulty removing stylet from the endotracheal tube and possible PVC sheath separation were received. 73,281 units 2014-04-29

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer