Aisys

Aisys CS2 With ET Control

Registry build 21.09.26
4manufacturers in China registered for this device type
2catalogue numbers in this listing
24510(k) clearances naming this product code
14recalls on this code

Who Else Makes It

Concentrated in Guangdong (2), Jiangsu (1), Hebei (1). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code BSZ
Manufacturer City Province Registered as Device types
Beijing Aeonmed Co., Ltd. Sanhe Hebei Contract manufacturer 7
Shenzhen Prunus Medical Co., Ltd. Shenzhen Guangdong Contract manufacturer 1
Shenzhen Mindray BIO-Medical Electronics Co., Ltd. Shenzhen Guangdong Specification developer 61
GE Medical Systems (China) Co., Ltd. Wuxi Jiangsu Contract manufacturer 57

Record

Regulatory record for Aisys
Listed by Datex-Ohmeda, Inc., United States
FDA product code BSZ
Device type Gas-Machine, Anesthesia
Device class Class 2
Regulation 21 CFR 868.5160
Establishment Specification developer, Manufacturer, Exporter
510(k) K170872
Record published 2022-07-21
Record revised 2022-05-12 (version 6)

Specifications

Specifications
MRI safety MR Unsafe
Label carries manufacturing date, serial number
Storage Storage environment humidity 15 to 95 % RH; Storage environment atmospheric pressure 56.66 to 105.66 KiloPascal; Storage environment temperature -25 to 60 °C

Catalogue Numbers

Catalogue numbers for Aisys
Catalogue number Size Status
CS2 WITH ET CONTROL In distribution
CS2 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
A9800 Anesthesia Workstation Oricare Inc. 22
Analgesia GAS Mixer, Digital MDM Delivery System Parker Hannifin Corp. 12
Aladin2 Datex-Ohmeda, Inc. 12
Penlon Penlon Ltd. 7
Analgesia GAS Mixer, MDM Delivery System Parker Hannifin Corp. 6
Codonics SLS500i Operating Software Codonics, Inc. 4
Codonics Safe Label System®(SLS) 500i Point of Care Station Codonics, Inc. 4
Spacelabs Healthcare Spacelabs Healthcare (Washington), Inc 4
Codonics Safe Label System®(SLS) 550i Point of Care Station – 144C Codonics, Inc. 3
Aestiva Datex-Ohmeda, Inc. 2
Infinium Medical Inc. Infinium Medical, Inc. 2
Aespire Datex-Ohmeda, Inc. 2

Showing 12 of 293. All products under Gas-Machine, Anesthesia

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K213867 2023-03-28
K172045 2017-11-03
K170872 2017-08-15
K151570 2016-01-21
K143530 2015-04-24
K132530 2013-12-20
K131945 2013-08-08
K123125 2013-02-06
K122445 2012-10-12
K112722 2011-12-16
K110213 2011-07-20
K090233 2009-03-05
K081844 2008-08-29
K073707 2008-01-30
K071142 2007-06-06
K061609 2006-06-27
K050676 2005-04-12
K050626 2005-03-25
K050055 2005-02-04
K042154 2004-08-31
K040743 2004-04-22
K032803 2004-03-10
K000706 2000-05-11
K993410 2000-04-25

Recalls Naming This Product

31 recalls name this product by its own identifiers, the UDI on its label or the 510(k) it is cleared under.

Recalls naming the identifiers of Aisys
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Datex-Ohmeda, Inc. 510(k) number 2026-07-30 Not classified Nonconforming Material/Component Anesthesia Delivery Systems containing certain electronic gas mixer assemblies can automatically transition to Alternate O2 control. In Alternate O2 control, the system delivers 100% O2 to the breathing system enabling continued controlled 475 units
Datex-Ohmeda, Inc. 510(k) number 2026-07-30 Not classified Nonconforming Material/Component Anesthesia Delivery Systems containing certain electronic gas mixer assemblies can automatically transition to Alternate O2 control. In Alternate O2 control, the system delivers 100% O2 to the breathing system enabling continued controlled 140 units
Datex-Ohmeda, Inc. 510(k) number 2026-07-30 Not classified Nonconforming Material/Component Anesthesia Delivery Systems containing certain electronic gas mixer assemblies can automatically transition to Alternate O2 control. In Alternate O2 control, the system delivers 100% O2 to the breathing system enabling continued controlled 7 units
Datex-Ohmeda, Inc. 510(k) number 2026-07-30 Not classified Nonconforming Material/Component Anesthesia Delivery Systems containing certain electronic gas mixer assemblies can automatically transition to Alternate O2 control. In Alternate O2 control, the system delivers 100% O2 to the breathing system enabling continued controlled 410 units
Datex-Ohmeda, Inc. 510(k) number 2024-07-12 Class I Device Design Potential issue that may arise if the limb of a patient breathing circuit is mistakenly connected to the Auxiliary Common Gas Outlet
(ACGO) port.
20,097 units
Datex-Ohmeda, Inc. 510(k) number 2024-07-12 Class I Device Design Potential issue that may arise if the limb of a patient breathing circuit is mistakenly connected to the Auxiliary Common Gas Outlet
(ACGO) port.
Datex-Ohmeda, Inc. 510(k) number 2024-07-12 Class I Device Design Potential issue that may arise if the limb of a patient breathing circuit is mistakenly connected to the Auxiliary Common Gas Outlet
(ACGO) port.
12,036 units
Datex-Ohmeda, Inc. 510(k) number 2024-07-12 Class I Device Design Potential issue that may arise if the limb of a patient breathing circuit is mistakenly connected to the Auxiliary Common Gas Outlet
(ACGO) port.
10,338 units
Datex-Ohmeda, Inc. 510(k) number 2024-07-12 Class I Device Design Potential issue that may arise if the limb of a patient breathing circuit is mistakenly connected to the Auxiliary Common Gas Outlet
(ACGO) port.
9,349 units
Datex-Ohmeda, Inc. 510(k) number 2024-07-12 Class I Device Design Potential issue that may arise if the limb of a patient breathing circuit is mistakenly connected to the Auxiliary Common Gas Outlet
(ACGO) port.
12,559 units
Datex-Ohmeda, Inc. 510(k) number 2024-07-12 Class I Device Design Potential issue that may arise if the limb of a patient breathing circuit is mistakenly connected to the Auxiliary Common Gas Outlet
(ACGO) port.
4,790 units
Datex-Ohmeda, Inc. 510(k) number 2024-07-12 Class I Device Design Potential issue that may arise if the limb of a patient breathing circuit is mistakenly connected to the Auxiliary Common Gas Outlet
(ACGO) port.
15,739 units
Datex-Ohmeda, Inc. UDI-DI 2024-07-12 Class I Device Design Potential issue that may arise if the limb of a patient breathing circuit is mistakenly connected to the Auxiliary Common Gas Outlet
(ACGO) port.
92 units
Datex-Ohmeda, Inc. 510(k) number 2024-07-12 Class I Device Design Potential issue that may arise if the limb of a patient breathing circuit is mistakenly connected to the Auxiliary Common Gas Outlet
(ACGO) port.
649 units
GE Medical Systems, LLC 510(k) number 2022-06-01 Class I Process control There is a potential reversal of the O2 and air cylinder pressure transducer connections. 5,372 devices 2024-10-21
GE Medical Systems, LLC 510(k) number 2022-05-27 Class II Process control The base of the anesthesia system can have a crack and could potentially fracture resulting in a tip or overbalance of the anesthesia system. This can result in potential injury if it falls on a person. 667 devices
GE Medical Systems, LLC 510(k) number 2022-04-25 Class II Under Investigation by firm Backup batteries can fail earlier than their estimated life. 6,612 devices
GE Medical Systems, LLC 510(k) number 2022-04-25 Class II Under Investigation by firm Backup batteries can fail earlier than their estimated life. 88,347 batteries
GE Medical Systems, LLC 510(k) number 2021-08-02 Class II Under Investigation by firm The flow sensors built prior to June 2021 could have damaged tubes with small punctures or cuts that could cause leaks resulting in incorrect anesthesia machine tidal volumes potentially leading to over-delivery of volume to the patient. Estimated 310,072 flow sensors
GE Medical Systems, LLC 510(k) number 2021-08-02 Class II Under Investigation by firm The flow sensors built prior to June 2021 could have damaged tubes with small punctures or cuts that could cause leaks resulting in incorrect anesthesia machine tidal volumes potentially leading to over-delivery of volume to the patient. Estimated 310,072 flow sensors
GE Medical Systems, LLC 510(k) number 2020-09-17 Class II Process control Flow sensors could have damaged tubes in the form of small punctures or cuts. 2 devices
GE Medical Systems, LLC 510(k) number 2020-09-17 Class II Process control Flow sensors could have damaged tubes in the form of small punctures or cuts. 88 devices
GE Medical Systems, LLC 510(k) number 2020-09-17 Class II Process control Flow sensors could have damaged tubes in the form of small punctures or cuts. 101 devices
GE Medical Systems, LLC 510(k) number 2020-09-17 Class II Process control Flow sensors could have damaged tubes in the form of small punctures or cuts. 37 devices
GE Medical Systems, LLC 510(k) number 2018-09-27 Class II Software design Upgraded Aisys anesthesia devices and Aisys CS2 anesthesia devices with PSVPro Spontaneous Breathing Modes do not provide the PSVPro ventilation mode feature of transitioning to SIMV PCV backup ventilation mode. PSVPro Spontaneous Breathing 4,207 units total 2021-04-12
GE Medical Systems, LLC 510(k) number 2018-09-27 Class II Software design Upgraded Aisys anesthesia devices and Aisys CS2 anesthesia devices with PSVPro Spontaneous Breathing Modes do not provide the PSVPro ventilation mode feature of transitioning to SIMV PCV backup ventilation mode. PSVPro Spontaneous Breathing 4,207 units total 2021-04-12
GE Medical Systems, LLC 510(k) number 2018-09-27 Class II Software design Upgraded Aisys anesthesia devices and Aisys CS2 anesthesia devices with PSVPro Spontaneous Breathing Modes do not provide the PSVPro ventilation mode feature of transitioning to SIMV PCV backup ventilation mode. PSVPro Spontaneous Breathing 4,207 units total 2021-04-12
GE Medical Systems, LLC 510(k) number 2017-10-04 Class II Process control Non-Conforming devices were shipped from the service center without proper evaluation and therefore may be nonconforming. 2 2020-04-10
GE Medical Systems, LLC 510(k) number 2016-03-15 Class II Employee error The vacuum suction tubing could be kinked within the machine resulting in suction less than the 20 lpm required by ISO 10079-3. This could result in inadequate suction performance to clear the airway and inadequate ventilation of the patien 952 (488 US; 464 OUS) 2016-11-07
GE Medical Systems, LLC 510(k) number 2016-02-17 Class II Nonconforming Material/Component GE Healthcare has recently become aware of a potential safety issue involving a momentary, self-correcting anesthetic agent bolus when using 21% oxygen on all Aisys CS2 and upgraded Aisys anesthesia devices. 5496 2018-09-04
GE Medical Systems, LLC 510(k) number 2015-12-15 Class II Nonconforming Material/Component The Drive Gas Check Valve of certain Anesthesia products could become stuck in a fixed open position, which could cause pressure to build in the mechanical ventilation cycle. If this issue is left unresolved, it could result in excessive or 2627 2016-09-21

Recalls

The FDA has not published a severity grade for these. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2008-08-28 Not classified Manufacturing material removal The electronic vaporization system in the GE Aisys Anesthesia machine contains the following components: Backpressure Valve, Inflow Check Valve and Cassette Interface Board, that can contribute to independent failures. 1571 2016-03-08

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer