Neo-Tee T-Piece Resuscitator

45 catalogue numbers from 10-50821, listed by Mercury Medical Enterprises, LLC, United States, under Ventilator, Emergency, Powered (Resuscitator). 4 manufacturers in China are registered for this product code.

Registry build 21.09.26
4manufacturers in China registered for this device type
45catalogue numbers in this listing
3recalls on this code

Who Else Makes It

Concentrated in Guangdong (3), Fujian (1). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code BTL
Manufacturer City Province Registered as Device types
GaleMed (Xiamen) Co., Ltd. Xiamen Fujian Contract manufacturer 33
Sunmed AP, Ltd. Zhuhai Guangdong Contract manufacturer 18
Sunmed AP, Ltd., Warehouse NO. 2 Zhuhai Guangdong Contract manufacturer 16
Dongguan Plastiflex Hose Technology Ltd Dongguan Guangdong Contract manufacturer 3

Record

Regulatory record for Neo-Tee T-Piece Resuscitator
Listed by Mercury Medical Enterprises, LLC, United States
FDA product code BTL
Device type Ventilator, Emergency, Powered (Resuscitator)
Device class Class 2
Regulation 21 CFR 868.5925
Establishment Contract manufacturer, Repacker / relabeller, Manufacturer
510(k) K093913
Record published 2015-09-24
Record revised 2021-07-13 (version 6)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Single use Yes
Prescription Prescription only
Latex Labelled latex-free
Label carries lot or batch number, expiry date, manufacturing date
Packaging Pack of 10
Distribution end date 2021-07-12

Catalogue Numbers

Catalogue numbers for Neo-Tee T-Piece Resuscitator
Catalogue number Size Status
10-50821 In distribution
10-50809 In distribution
10-50839 In distribution
10-50802 In distribution
10-50823 In distribution
10-50811 In distribution
10-50838 In distribution
10-50807 In distribution
10-50810 In distribution
10-50841 In distribution
10-50806 In distribution
10-50823 In distribution
10-50803 In distribution
10-50829 In distribution
10-50808 In distribution
10-50822 In distribution
10-50825 In distribution
10-50805 In distribution
10-50842 In distribution
10-50815 In distribution
10-50840 In distribution
10-50837 In distribution
10-50831 In distribution
10-50832 In distribution
10-50843 In distribution
10-50814 In distribution
10-50804 Withdrawn
10-50826 Withdrawn
10-50816 Withdrawn
10-50819 Withdrawn
10-50800 Withdrawn
10-50833 Withdrawn
10-50820 Withdrawn
10-50824 Withdrawn
10-50818 Withdrawn
10-50834 Withdrawn
10-50830 Withdrawn
10-50812 Withdrawn
10-50801 Withdrawn
10-50828 Withdrawn
10-50817 Withdrawn
10-50836 Withdrawn
10-50827 Withdrawn
10-50813 Withdrawn
10-50835 Withdrawn

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Life Support Products Allied Medical LLC 50
Pneupac ICU Medical, Inc 38
Allied Medical LLC Allied Medical LLC 19
Fisher & Paykel Healthcare Fisher & Paykel Healthcare, Ltd. 18
AincA Anesthesia Associates, Inc. 17
Neo-Tee T-Piece Resuscitator Circuit Mercury Medical Enterprises, LLC 12
Life Support Products (LSP) Allied Medical LLC 12
Moves Thornhill Research Inc. 11
Ventlab Ventlab, LLC 7
Resusa-Tee T-Piece Resuscitator Mercury Medical Enterprises, LLC 7
Curaplex Bound Tree Medical, LLC 5
Macs Airon Corporation 4

Showing 12 of 70. All products under Ventilator, Emergency, Powered (Resuscitator)

Recalls Naming This Product

3 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of Neo-Tee T-Piece Resuscitator
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Mercury Medical Enterprises, LLC 510(k) number 2024-12-10 Class I Process change control Gas powered emergency resuscitator has a circuit flow controller manufactured with an undersized spring, which may cause resuscitator not reach the high and low ends of the PIP and PEEP pressure ranges, which may cause a loss of positive pr 37370
Mercury Medical Enterprises, LLC 510(k) number 2024-08-30 Class I Process control Manual resuscitator circuit flow controller may come apart due to a missing manufacturing step. 1,300 units
Mercury Medical Enterprises, LLC 510(k) number 2015-10-22 Class II Device Design Incorrect use of T-Piece resuscitators will result in complete occlusion of the patient circuit and consequent failure to ventilate the patient. 753,245 devices 2017-10-13

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer