Medline Industries, Inc.

RESUSCITATOR,MAN.INF,BAG,FILTER,PEEP,CO2

Registry build 21.09.26
8manufacturers in China registered for this device type
53catalogue numbers in this listing

Who Else Makes It

Concentrated in Fujian (4), Zhejiang (1), Guangdong (1). 5 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code BTM
Manufacturer City Province Registered as Device types
Flexicare Medical (Dongguan) Ltd. Dongguan Guangdong Contract manufacturer 48
GaleMed (Xiamen) Co., Ltd. Xiamen Fujian Contract manufacturer 33
Polymed (Xiamen) Plastic Industrial Co., Ltd. Xiamen Fujian Contract manufacturer 17
VR Medical Technology Co., Ltd. Kunshan Jiangsu Contract manufacturer 13
Ambu Limited Xiang Yu F.T.Z., Xiamen Fujian Contract manufacturer 11
Huzhou Junda Industry Co., Ltd. Anji Zhejiang Contract manufacturer 129
Laerdal Medical (Suzhou) Co., Ltd. 215009 Suzhou Jiangsu Province Repacker / relabeller 12
Xiamen Compower Medical Tech. Co., Ltd. Xiamen Fujian Contract manufacturer 9

Record

Regulatory record for Medline Industries, Inc.
Listed by Medline Industries, Inc., United States
FDA product code BTM
Device type Ventilator, Emergency, Manual (Resuscitator)
Device class Class 2
Regulation 21 CFR 868.5915
Record published 2015-10-15
Record revised 2019-10-21 (version 4)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Single use Yes
Prescription Prescription only
Supplied as a kit Yes
Latex Labelled latex-free
Label carries lot or batch number, expiry date, manufacturing date
Packaging Pack of 6, pack of 12, case of 8, case of 6

Catalogue Numbers

Catalogue numbers for Medline Industries, Inc.
Catalogue number Size Status
CPRM1126K In distribution
CPRM1126FP In distribution
CPRM2226F In distribution
CPRM3312FPC In distribution
CPRM3412P In distribution
CPRM3312FP In distribution
CPRM1116PC In distribution
CPRM2226FC In distribution
CPRM3322FC In distribution
CPRM2216C In distribution
CPRM1116P In distribution
CPRM2226 In distribution
CPRM1116FC In distribution
CPRM1126FPC In distribution
CPRM2226C In distribution
DYNJA128808A In distribution
CPRM1126C In distribution
CPRM1126FC In distribution
CPRM1126PC In distribution
CPRM1116WM In distribution
CPRM3322P In distribution
CPRM2216PC In distribution
CPRM1116FP In distribution
CPRM2216FC In distribution
CPRM3322C In distribution
CPRM3312P In distribution
CPRM3312FC In distribution
CPRM1126 In distribution
CPRM1116C In distribution
CPRM1126P In distribution
CPRM1116 In distribution
CPRM3322F In distribution
CPRM2226FPC In distribution
CPRM3312C In distribution
CPRM1116F In distribution
CPRM2226FP In distribution
CPRM3312F In distribution
CPRM3312 In distribution
CPRM1116FPC In distribution
CPRM2216FPC In distribution
CPRM3322 In distribution
CPRM1116CF In distribution
CPRM2216 In distribution
CPRM2216FP In distribution
CPRM3322PC In distribution
CPRM3322FPC In distribution
CPRM2226PC In distribution
CPRM2226P In distribution
CPRM1116K In distribution
CPRM3312PC In distribution
CPRM3322FP In distribution
CPRM1126F In distribution
CPRM2216P In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Ventlab Ventlab, LLC 405
CPR-2 Bag Mercury Medical Enterprises, LLC 231
CPR Bag Mercury Medical Enterprises, LLC 187
Vital Signs™ Airlife, Inc. 102
Medline Medline Industries, Inc. 78
Spur® II Pediatric ResuscitatorSingle Patient Use Resuscitator Ambu A/S 74
Spur® II Adult ResuscitatorSingle Patient Use Resuscitator Ambu A/S 66
Hudson RCI Teleflex Medical LLC 56
Portex ICU Medical, Inc 45
Spur® II Infant ResuscitatorSingle Patient Use Resuscitator Ambu A/S 45
Curaplex® Bound Tree Medical, LLC 38
Vital Signs Carefusion 31

Showing 12 of 342. All products under Ventilator, Emergency, Manual (Resuscitator)

Recalls Naming This Product

1 recall names this product by its own identifier, the UDI on its label.

Recalls naming the identifiers of Medline Industries, Inc.
Recalled by Identified by Initiated FDA class Root cause Reason Quantity
SunMed Group Holdings, LLC UDI-DI 2025-05-01 Class I Process control Affected lots were manufactured with B/V Filter incorrectly attached to the wrong port (patient port instead of the exhalation port). If not noticed prior to patient use, there would be interruption or delay in patient resuscitation, which 11,358

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer