iCOR
FH With Soft - Flex AND Swivel
Who Else Makes It
Concentrated in Zhejiang (10), Guangdong (8), Jiangsu (5). 11 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Flexicare Medical (Dongguan) Ltd. | Dongguan | Guangdong | Contract manufacturer | 48 |
| Vincent Medical (Dong Guan) Manufacturing Co., Ltd. | Dong Guan | Guangdong | Contract manufacturer | 29 |
| Amsino Medical (Shanghai) Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 22 |
| Zhejiang Haisheng Medical Device Co., Ltd. | Shaoxing | Zhejiang | Contract manufacturer | 21 |
| Sunmed AP, Ltd. | Zhuhai | Guangdong | Contract manufacturer | 18 |
| Sunmed AP, Ltd., Warehouse NO. 2 | Zhuhai | Guangdong | Contract manufacturer | 16 |
| IPE Plastic & Hardware Industy, Ltd | Dongguan | Guangdong | Contract manufacturer | 15 |
| VR Medical Technology Co., Ltd. | Kunshan | Jiangsu | Contract manufacturer | 13 |
| Zhejiang Runqiang Medical Instruments Co., Ltd. | Jiaxing | Zhejiang | Contract manufacturer | 9 |
| Ningbo Boya Medical Equipment Co., Ltd. | Yuyao | Zhejiang | Contract manufacturer | 8 |
| GVS Technology (Suzhou) Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 5 |
| Boen Healthcare Co., Ltd. | Suzhou | Jiangsu | Specification developer | 263 |
Showing 12 of 29. All 29 manufacturers in China registered for Condenser, Heat And Moisture (Artificial Nose)
Record
| Listed by | Teleflex Medical LLC, United States |
|---|---|
| FDA product code | BYD |
| Device type | Condenser, Heat And Moisture (Artificial Nose) |
| Device class | Class 1 |
| Regulation | 21 CFR 868.5375 |
| Establishment | Specification developer, Complaint-file establishment, Manufacturer |
| 510(k) | K925622 |
| Record published | 2016-09-16 |
| Record revised | 2020-09-22 (version 4) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date |
| Packaging | Case of 24, box of 25, box of 30, box of 15, box of 10, box of 20 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| IPN040577 | In distribution | |
| IPN040598 | In distribution | |
| IPN040597 | In distribution | |
| IPN040483 | In distribution | |
| IPN040455 | In distribution | |
| IPN040509 | In distribution | |
| IPN040596 | In distribution | |
| IPN040559 | In distribution | |
| IPN040517 | In distribution | |
| IPN040563 | In distribution | |
| IPN040551 | In distribution | |
| IPN040515 | In distribution | |
| IPN040460 | In distribution | |
| IPN040537 | In distribution | |
| IPN040527 | In distribution | |
| IPN040503 | In distribution | |
| IPN040498 | In distribution | |
| IPN040584 | In distribution | |
| IPN040475 | In distribution | |
| IPN040571 | In distribution | |
| IPN040486 | In distribution | |
| IPN040471 | In distribution | |
| IPN040523 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Portex | ICU Medical, Inc | 34 |
| Hudson RCI | Teleflex Medical LLC | 34 |
| Gibeck | Teleflex Medical LLC | 27 |
| DAR | Covidien LP | 21 |
| AirLife™ | Airlife, Inc. | 20 |
| Medisize® | Medisize B.V. | 19 |
| AirLife™ | Vyaire Medical, Inc. | 13 |
| HME | Pepper Medical, Inc. | 11 |
| ThermoFlo® | Typenex Medical, LLC | 11 |
| InHealth Technologies; Blom-Singer | Freudenberg Medical, LLC | 11 |
| Heat Moisture Exchanger | Sunset Healthcare Solutions, Inc. | 9 |
| Closed Suction System | VR Medical Technology Co., Ltd. | 7 |
Showing 12 of 219. All products under Condenser, Heat And Moisture (Artificial Nose)
Recalls
2 of these are Class I. Class I is the FDA’s most serious grade: a reasonable probability of serious injury or death. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2022-04-11 | Class II | Device Design | Reports received of torn corrugated breathing tubes. | 59,581 eaches | |
| 2015-12-03 | Class II | Device Design | Cracking may occur at the 15mm and 22mm ISO female connector. | 2,700 units | 2017-01-24 |
| 2015-12-03 | Class II | Release of Material/Component prior to receiving test results | Cracks may occur at the 15mm and 22mm ISO female connector. | 2,700 ea. | 2017-04-14 |
| 2015-01-12 | Class I | Process control | Defects: Cracks that may occur in the center of the corrugated flex tube of the 15 mm and 22 mm ISO female connector. | 100 units | 2016-05-10 |
| 2014-12-04 | Class I | Process control | Connector mount cracks which may lead to a leak failure during use and necessitate immediate replacement in the breathing circuit. If leak exists and is left untreated, patient may be deprived of adequate anesthetic gases over a period of | 18 | 2017-03-21 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.