Dust CAP, 22f

Catalogue number 1978000, listed by Intersurgical Ltd., United Kingdom, under Connector, Airway (Extension). 20 manufacturers in China are registered for this product code.

Registry build 21.09.26
20manufacturers in China registered for this device type
1catalogue number
4510(k) clearances naming this product code
4recalls on this code

Who Else Makes It

Concentrated in Guangdong (7), Jiangsu (6), Zhejiang (3). 9 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code BZA
Manufacturer City Province Registered as Device types
Flexicare Medical (Dongguan) Ltd. Dongguan Guangdong Contract manufacturer 48
Vincent Medical (Dong Guan) Manufacturing Co., Ltd. Dong Guan Guangdong Contract manufacturer 29
Zhejiang Haisheng Medical Device Co., Ltd. Shaoxing Zhejiang Contract manufacturer 21
Polymed (Xiamen) Plastic Industrial Co., Ltd. Xiamen Fujian Contract manufacturer 17
Intersurgical Medical Apparatus (Changzhou) Co., Ltd. Changzhou Jiangsu Contract manufacturer 12
Shenzhen Insighters Medical Technology Co., Ltd. Shenzhen Guangdong Contract manufacturer 10
Dongguan Junhai Medical Device Co., Ltd. Dong Guang Guangdong Contract manufacturer 9
Shanghai Draeger Medical Instrument Co., Ltd. Shanghai Shanghai Contract manufacturer 4
Suzhou Yuyue Medical Technology Co., Ltd. Suzhou Jiangsu Contract manufacturer 4
Boen Healthcare Co., Ltd. Suzhou Jiangsu Specification developer 263
Suzhou Meccan Import and Export Corp. Suzhou Jiangsu Contract manufacturer 71
GaleMed (Xiamen) Co., Ltd. Xiamen Fujian Contract manufacturer 33

Showing 12 of 20. All 20 manufacturers in China registered for Connector, Airway (Extension)

Record

Regulatory record for Dust CAP, 22F
Listed by Intersurgical Ltd., United Kingdom
FDA product code BZA
Device type Connector, Airway (Extension)
Device class Class 1
Regulation 21 CFR 868.5810
Establishment Specification developer, Complaint-file establishment, Manufacturer, Exporter
Premarket notification Exempt
Record published 2021-10-14
Record revised 2025-02-11 (version 3)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Single use Yes
Prescription Prescription only
Latex Labelled latex-free
Label carries lot or batch number, expiry date
Packaging Pack of 180, pack of 45

Catalogue Numbers

Catalogue numbers for Dust CAP, 22F
Catalogue number Size Status
1978000 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
AincA® Anesthesia Associates, Inc. 158
Hudson RCI Teleflex Medical LLC 126
AirLife™ Airlife, Inc. 66
DAR Covidien LP 65
Connector, Airway (Extension) VBM Medizintechnik Gmbh 58
Medline Industries, Inc. Medline Industries, Inc. 24
Connector, Airway (Extension) Galemed Corp. 23
Vital Signs™ AirLife Finland Oy 22
Airway Adapters Respironics Novametrix, LLC 19
Oxygen Connector/Adapter Sunset Healthcare Solutions, Inc. 18
Flexicare Flexicare Medical Ltd. 15
Adaptors/Connectors Westmed, Inc. 15

Showing 12 of 279. All products under Connector, Airway (Extension)

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K921511 1992-06-17
K921512 1992-06-17
K911425 1991-06-24
K911421 1991-06-24

Recalls

4 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2019-08-07 Class II Under Investigation by firm The port may crack in the swivel elbow where the flip cap is inserted, and these cracks could possibly leak if they reach a significant size. 46,450 pieces 2020-12-15
2019-08-07 Class II Under Investigation by firm The port may crack in the swivel elbow where the flip cap is inserted, and these cracks could possibly leak if they reach a significant size. 50,400 pieces 2020-12-15
2019-08-07 Class II Under Investigation by firm The port may crack in the swivel elbow where the flip cap is inserted, and these cracks could possibly leak if they reach a significant size. 19,200 pieces 2020-12-15
2019-08-07 Class II Under Investigation by firm The port may crack in the swivel elbow where the flip cap is inserted, and these cracks could possibly leak if they reach a significant size. 115,200 pieces 2020-12-15

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer