BiPAP System One 60 Series
BiPAP AutoBiFlex with Heated Tube Humidifier, Standard Tube, BlueTooth, System One 60 Series, Canada
Who Else Makes It
Concentrated in Guangdong (8), Jiangsu (2), Zhejiang (2). 9 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| GaleMed (Xiamen) Co., Ltd. | Xiamen | Fujian | Contract manufacturer | 33 |
| Modern Medical Equipment Manufacturing Ltd. | Heng Li, Dongguan | Guangdong | Contract manufacturer | 26 |
| Suzhou Avon Textile Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 12 |
| Mehow Innovative (Huizhou) Ltd. | Huizhou | Guangdong | Contract manufacturer | 11 |
| Respironics Medical Products (Shenzhen) Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 8 |
| Hunan Beyond Medical Technology Co., Ltd. | Changsha | Hunan | Contract manufacturer | 3 |
| Shanghai Baron Technologies Co Ltd | Shanghai | Shanghai | Contract manufacturer | 3 |
| BMC(Dongguan) Medical Co., Ltd. | Dongguan | Guangdong | Contract manufacturer | 2 |
| Zhejiang Baron Technologies Co., Ltd. | Pinghu | Zhejiang | Contract manufacturer | 1 |
| Modern Medical Equipment Manufacturing (Qing Yuan) Ltd | Qing Yuan | Guangdong | Contract manufacturer | 26 |
| Shenzhen Sany Pioneer Technology Co., Ltd. | Shenzhen | Guangdong | Manufacturer | 9 |
| Resvent Medical Technology Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 6 |
Showing 12 of 18. All 18 manufacturers in China registered for Ventilator, Non-Continuous (Respirator)
Record
| Listed by | Respironics Inc., United States |
|---|---|
| FDA product code | BZD |
| Device type | Ventilator, Non-Continuous (Respirator) |
| Device class | Class 2 |
| Regulation | 21 CFR 868.5905 |
| Establishment | Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter |
| 510(k) | K113068 |
| Record published | 2016-08-20 |
| Record revised | 2021-03-08 (version 7) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Prescription | Prescription only |
| Label carries | serial number |
| Storage | Storage environment humidity 15 to 95 % RH; Storage environment temperature -4 to 140 °F; Storage environment temperature -20 to 60 °C |
| Distribution end date | 2023-07-13 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| BiPAP Auto BiFlex, wiith Humidifier, System One 60 Series, PT | In distribution | |
| BiPAP Auto BiFlex, w/HT Humid System One 60 Series, INTL | In distribution | |
| BiPAP Auto BiFlex with Humidifier System One 60 Series,ES | In distribution | |
| BiPAP Auto Bi-Flex w/ Humid, BTOOTH Sys One 60 Srs, US | In distribution | |
| BiPAP Pro BiFlex, with Humidifier, 60 Series, CA | In distribution | |
| BiPAP Pro, INTL | In distribution | |
| BiPAP Pro BiFlex, System One 60 Series, FI | In distribution | |
| BiPAP Auto BiFlex, System One 60 Series, PT | In distribution | |
| BiPAP Pro BiFlex H Tube Humid, St Tube, BTooth, 60 Srs, CA | In distribution | |
| BiPAP Auto BiFlex w/Hum Sys One 60 Series, ND | In distribution | |
| BiPAP Pro BiFlex, 60 Series, CA | In distribution | |
| BiPAP Pro BiFlex, System One 60 Series, ND | In distribution | |
| BiPAP Auto BiFlex w/Humidifier, System One 60 Series, AHP | In distribution | |
| BiPAP Pro BiFlex w/Htd Humid, BTooth, Sys One 60Srs, AHP | In distribution | |
| BiPAP Pro BiFlex, w/Htd Humid, Sys One 60 Srs, AHP | In distribution | |
| BiPAP Auto BiFlex, System One 60 Series, SE | In distribution | |
| BiPAP Auto BiFlex w/Humidifier System One 60 Series,GB | In distribution | |
| BiPAP Auto BiFlex, BlueTooth, 60 Series, CA | In distribution | |
| BiPAP Auto BiFlex, with Humidifier, System One 60 Series, SE | In distribution | |
| BiPAP Auto BiFlex System One 60 Series, AHP | In distribution | |
| BiPAP Auto Bi-Flex w/HT Humid, BTOOTH Sys One 60 Srs, US | In distribution | |
| BiPAP Auto BiFlex, System One 60 Series, NO | In distribution | |
| BiPAP Pro BiFlex, w/Humidifer, System One 60 Series,PT | In distribution | |
| BiPAP Pro BiFlex with Humidifier, System One 60 Srs, AHP | In distribution | |
| BiPAP Pro BiFlex w/Humid, BlueTooth, Sys One 60Srs, AHP | In distribution | |
| BiPAP Pro BiFlex+, w/Humid, w/BlueTooth, 60 Series, CA | In distribution | |
| BiPAP Pro BiFlex, Sys One 60 Srs, PT | In distribution | |
| BiPAP Pro BiFlex with Humidifier, System One 60 Series, FI | In distribution | |
| BiPAP Pro BlueTooth, US | In distribution | |
| BiPAP Auto BiFlex w/H Tube Humid, St Tube, 60 Srs, CA | In distribution | |
| BiPAP Auto BiFlex with Humidifier 60 Series, CA | In distribution | |
| BiPAP Auto BiFlex w/ Humidifier, BlueTooth, 60 Series, CA | In distribution | |
| BiPAP Pro BiFlex+ w/H Tube Humid, w/BTooth, 60 Srs, CA | In distribution | |
| BiPAP Pro, CA | In distribution | |
| BiPAP Pro BiFlex System One 60 Series US | In distribution | |
| BiPAP Auto, CA | In distribution | |
| BiPAP Auto BiFlex, w/Humid System One 60 Series,US | In distribution | |
| BiPAP Pro, US | In distribution | |
| BiPAP Pro BiFlex, with Humidifier, System One 60 Srs,GB | In distribution | |
| BiPAP Pro BiFlex, w/H Tube Humid, 60 Series, CA | In distribution | |
| BiPAP Pro C-Flex+ HTHum,BT,SystemOne, 60Series, US | In distribution | |
| BiPAP Auto BlueTooth, US | In distribution | |
| BiPAP Pro BiFlex+, with BlueTooth, 60 Series, CA | In distribution | |
| BiPAP Pro BiFlex, BlueTooth, System One 60 Series, AHP | In distribution | |
| BiPAP Pro BiFlex w/Humidifier, Sys One 60 Series, NO | In distribution | |
| BiPAP Auto, US | In distribution | |
| BiPAP Pro BiFlex with Humidifier, System One 60 Series, ES | In distribution | |
| BiPAP Auto BiFlex, System One 60 Series, GB | In distribution | |
| BiPAP Auto BiFlex System One 60 Series INT | In distribution | |
| BiPAP Pro BiFlex, w/HT Humid System One 60 Series, US | In distribution | |
| BiPAP Pro BiFlex, w/Humid System One 60 Series INT | In distribution | |
| BiPAP Pro BiFlex w/Hum Sys One 60 Srs, ND | In distribution | |
| BiPAP Auto BiFlex, BlueTooth, System One 60 Series, AHP | In distribution | |
| BiPAP Auto, INTL | In distribution | |
| BiPAP Auto BlueTooth, CA | In distribution | |
| BiPAP Auto BiFlex w/Humid, BTooth, SystemOne 60Srs, AHP | In distribution | |
| BiPAP Pro BiFlex, System One 60 Series, ES | In distribution | |
| BiPAP Auto BiFlex, System One 60 Series, ND | In distribution | |
| BiPAP Pro BiFlex, System One 60 Series, GB | In distribution | |
| BiPAP AutoBiFlex w/H Tube Humid, BTooth, 60 Srs, CA | In distribution | |
| BiPAP Auto Bi-Flex, BTOOTH System One 60 Series, US | In distribution | |
| BiPAP Auto BiFlex, System One 60 Series, FI | In distribution | |
| BiPAP AutoBiFlex w/H Tube Hum, St Tube, BTooth, 60 Srs, CA | In distribution | |
| BiPAP Pro Bi-Flex w/ Humid, BTOOTH Sys One 60 Srs, US | In distribution | |
| BiPAP Pro BiFlex, System One 60 Series, SE | In distribution | |
| BiPAP Auto BiFlex, w/HT Humid System One 60 Series, US | In distribution | |
| BiPAP AutoBiFlex w/HTD Humid, BTooth, Sys One 60Srs, AHP | In distribution | |
| BiPAP Pro BiFlex System One 60 Series INT | In distribution | |
| BiPAP Pro, Bluetooth, CA | In distribution | |
| BiPAP Auto BiFlex, w/HTD Humid, System One 60 Srs, AHP | In distribution | |
| BiPAP Pro BiFlex, System One 60 Series, AHP | In distribution | |
| BiPAP Pro BiFlex, System One 60 Series, NO | In distribution | |
| BiPAP Pro BiFlex, w/Humidifier, System One 60 Series, SE | In distribution | |
| BiPAP Auto BiFlex w/H Tube Humid, 60 Series, CA | In distribution | |
| BiPAP Auto BiFlex, 60 Series, CA | In distribution | |
| BiPAP Pro Bi-Flex, BlueTooth System One 60 Series, US | In distribution | |
| BiPAP Auto BiFlex with Humidifier System One 60 Series,FI | In distribution | |
| BiPAP Auto, DE | In distribution | |
| BiPAP Auto BiFlex with Humidifier, System One 60 Series,NO | In distribution | |
| BiPAP Pro BiFlex, w/Humid System One 60 Series, US | Withdrawn | |
| BiPAP Pro, CN | Withdrawn | |
| BiPAP Auto BiFlex, System One 60 Series, FR | Withdrawn | |
| BiPAP Pro BiFlex, w/HT Humid System One 60 Series, CN | Withdrawn | |
| BiPAP Pro Bi-Flex w/ Humid, System One 60 Series, CN | Withdrawn | |
| BiPAP Auto Bi-Flex w/ Humid, System One 60 Series, CNBiPAP Auto Bi-Flex w/ Humid | Withdrawn | |
| BiPAP Auto BiFlex, w/HTD Humid, Sys One 60Srs, AU | Withdrawn | |
| BiPAP Auto BiFlex System One 60 Series,US | Withdrawn | |
| BiPAP Auto, CN | Withdrawn | |
| BiPAP Auto BiFlex, w/HT Humid System One 60 Series, CN | Withdrawn | |
| BiPAP Pro BiFlex w/H Tube Humid, Sys One 60 Series, LA | Withdrawn | |
| BiPAP Auto BiFlex, w/HT Humid System One 60 Series LA | Withdrawn | |
| BiPAP Pro BiFlex, System One 60 Series, CN | Withdrawn | |
| BiPAP Auto BiFlex, BR | Withdrawn | |
| BiPAP Auto BiFlex, w/Humid System One 60 Series LA | Withdrawn | |
| BiPAP Auto BiFlex, System One 60 Series, DE | Withdrawn | |
| BiPAP Auto, BR | Withdrawn | |
| BiPAP Pro BiFlex, w/HT Humid System One 60 Series INT | Withdrawn | |
| BiPAP Pro, BR | Withdrawn | |
| BiPAP Auto BiFlex w/Humidifier, System One 60 Series, AU | Withdrawn | |
| BiPAP Pro BiFlex, BR | Withdrawn | |
| BiPAP Auto BiFlex, System One 60 Series, CN | Withdrawn | |
| BiPAP Auto BiFlex, System One 60 Series, AU | Withdrawn | |
| BiPAP Auto, JP | Withdrawn | |
| BiPAP Auto BiFlex System One 60 Series LA | Withdrawn | |
| BiPAP Auto, FR | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| DreamStation | Respironics Inc. | 386 |
| DreamWear | Respironics Inc. | 183 |
| REMstar System One 60 Series | Respironics Inc. | 163 |
| Fisher & Paykel Healthcare | Fisher & Paykel Healthcare, Ltd. | 152 |
| DeVilbiss | DeVilbiss Healthcare LLC. | 136 |
| Ventilator, Non-Continuous (Respirator) | Hans Rudolph, Inc. | 115 |
| Ventilator, Non-Continuous (Respirator) | Salter Labs | 85 |
| BiTrac Select | Pulmodyne Inc. | 79 |
| Yuwell Sleep Apnea Breathing Therapy Mask | Suzhou Yuyue Medical Technology Co., Ltd. | 76 |
| AF541 | Respironics Inc. | 71 |
| CPAP Masks | Sunset Healthcare Solutions, Inc. | 69 |
| Hudson RCI | Teleflex Medical LLC | 69 |
Showing 12 of 699. All products under Ventilator, Non-Continuous (Respirator)
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K231313 | 2023-07-28 |
| K210844 | 2021-08-24 |
| K210386 | 2021-07-12 |
| K201439 | 2020-09-25 |
| K200480 | 2020-07-10 |
| K183226 | 2019-10-18 |
| K181053 | 2019-01-04 |
| K151120 | 2016-04-15 |
| K152356 | 2016-01-08 |
| K150639 | 2015-09-18 |
| K140980 | 2015-02-10 |
| K142554 | 2015-01-09 |
| K140268 | 2014-10-20 |
| K132168 | 2013-11-20 |
| K131982 | 2013-10-18 |
| K130077 | 2013-05-21 |
| K122847 | 2013-03-06 |
| K122769 | 2012-10-09 |
| K121631 | 2012-10-05 |
| K120562 | 2012-07-17 |
| K120145 | 2012-03-30 |
| K113068 | 2011-12-16 |
| K110405 | 2011-06-06 |
| K103395 | 2011-03-24 |
| K110008 | 2011-02-17 |
| K102502 | 2010-12-22 |
| K091112 | 2009-05-15 |
| K082558 | 2009-03-25 |
| K072996 | 2007-12-27 |
| K061034 | 2006-06-23 |
| K053352 | 2006-02-15 |
| K052110 | 2005-10-20 |
| K050759 | 2005-06-15 |
| K043607 | 2005-01-28 |
| K041010 | 2004-05-05 |
| K032834 | 2004-03-04 |
| K033759 | 2004-02-19 |
| K031460 | 2003-06-24 |
| K021861 | 2002-06-19 |
| K012554 | 2002-01-29 |
| K011714 | 2001-06-28 |
| K010263 | 2001-03-29 |
| K002465 | 2000-09-08 |
| K000705 | 2000-09-08 |
| K000994 | 2000-06-22 |
| K992969 | 1999-11-10 |
| K993433 | 1999-10-27 |
| K993307 | 1999-10-27 |
| K992336 | 1999-08-13 |
| K991648 | 1999-05-28 |
| K963761 | 1997-04-18 |
| K964363 | 1997-01-30 |
| K962203 | 1996-12-05 |
| K963250 | 1996-11-14 |
| K953930 | 1996-09-30 |
| K961915 | 1996-08-15 |
| K961626 | 1996-07-18 |
| K954572 | 1996-06-26 |
| K945938 | 1996-01-31 |
| K954207 | 1996-01-31 |
| K953341 | 1996-01-30 |
| K936047 | 1995-03-29 |
| K925587 | 1993-09-14 |
| K925920 | 1993-07-21 |
| K920699 | 1992-12-07 |
| K911856 | 1991-08-09 |
| K905540 | 1991-01-30 |
Recalls Naming This Product
1 recall names this product by its own identifier, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|---|---|
| Respironics Inc. | 510(k) number | 2021-06-14 | Class I | Device Design | The polyester-based polyurethane (PE-PUR) foam may degrade into particles which may enter the device s the air pathway and be ingested or inhaled by the user, and the PE-PUR foam may off-gas certain chemicals. | 15,357,775 (10,307,186 in US, 5,039,748 OUS) in total |
Recalls
9 of these are Class I. Class I is the FDA’s most serious grade: a reasonable probability of serious injury or death. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2025-06-30 | Class I | Process control | Devices may possess a programming error resulting in an incorrect device configuration. | 28 units | |
| 2025-06-30 | Class I | Process control | Devices may possess a programming error resulting in an incorrect device configuration. | 57 units | |
| 2025-06-30 | Class I | Process control | Devices may possess a programming error resulting in an incorrect device configuration. | 8 units | |
| 2023-02-10 | Class I | Software design (manufacturing process) | A limited number of remediated Philips DreamStation units may experience communication issues when connecting to the cloud-based care management application. Should this be the case, this may affect the ability to download prescription sett | 1233 devices | |
| 2022-09-06 | Class I | Error in labeling | No contraindication/warning regarding magnetic components in CPAP masks for patients with implantable devices or metallic splinters in the eyes. | 930,813 units | |
| 2022-09-06 | Class I | Error in labeling | No contraindication/warning regarding magnetic components in CPAP masks for patients with implantable devices or metallic splinters in the eyes. | 9,191,280 units | |
| 2022-09-06 | Class I | Error in labeling | No contraindication/warning regarding magnetic components in CPAP masks for patients with implantable devices or metallic splinters in the eyes. | 42,954 units | |
| 2022-09-06 | Class I | Error in labeling | No contraindication/warning regarding magnetic components in CPAP masks for patients with implantable devices or metallic splinters in the eyes. | 5,661,639 units | |
| 2022-09-06 | Class I | Error in labeling | No contraindication/warning regarding magnetic components in CPAP masks for patients with implantable devices or metallic splinters in the eyes. | 6,237,558 units | |
| 2009-02-05 | Not classified | Nonconforming Material/Component | Malfunction of the J3 connection between the Heater Plate Main printed circuit assembly (PCA) and the heater plate may have an intermittent connection which may lead to excessive heat build-up on the humidifier PCA. | 449,585 units | 2012-07-05 |
| 2007-10-15 | Not classified | Environmental control | Foreign material: Glass fragments may present in the plastic bag material used to ship components. | 20950 units | 2009-09-01 |
| 2007-10-15 | Not classified | Environmental control | Foreign material: Glass fragments may present in the plastic bag material used to ship components. | 20950 units | 2009-09-01 |
| 2007-10-15 | Not classified | Environmental control | Foreign material: Glass fragments may present in the plastic bag material used to ship components. | 20950 units | 2009-09-01 |
| 2007-10-15 | Not classified | Environmental control | Foreign material: Glass fragments may present in the plastic bag material used to ship components. | 20950 units | 2009-09-01 |
| 2007-10-15 | Not classified | Environmental control | Foreign material: Glass fragments may present in the plastic bag material used to ship components. | 20950 units | 2009-09-01 |
| 2007-10-15 | Not classified | Environmental control | Foreign material: Glass fragments may present in the plastic bag material used to ship components. | 20950 units | 2009-09-01 |
| 2007-10-15 | Not classified | Environmental control | Foreign material: Glass fragments may present in the plastic bag material used to ship components. | 20950 units | 2009-09-01 |
| 2007-10-15 | Not classified | Environmental control | Foreign material: Glass fragments may present in the plastic bag material used to ship components. | 20950 units | 2009-09-01 |
| 2007-10-15 | Not classified | Environmental control | Foreign material: Glass fragments may present in the plastic bag material used to ship components. | 20950 units | 2009-09-01 |
| 2007-10-15 | Not classified | Environmental control | Foreign material: Glass fragments may present in the plastic bag material used to ship components. | 20950 units | 2009-09-01 |
| 2007-10-15 | Not classified | Environmental control | Foreign material: Glass fragments may present in the plastic bag material used to ship components. | 20950 units | 2009-09-01 |
| 2007-10-15 | Not classified | Environmental control | Foreign material: Glass fragments may present in the plastic bag material used to ship components. | 20950 units | 2009-09-01 |
| 2007-10-15 | Not classified | Environmental control | Foreign material: Glass fragments may present in the plastic bag material used to ship components. | 20950 units | 2009-09-01 |
| 2007-10-15 | Not classified | Environmental control | Foreign material: Glass fragments may present in the plastic bag material used to ship components. | 20950 units | 2009-09-01 |
| 2007-10-15 | Not classified | Environmental control | Foreign material: Glass fragments may present in the plastic bag material used to ship components. | 20950 units | 2009-09-01 |
| 2007-10-15 | Not classified | Environmental control | Foreign material: Glass fragments may present in the plastic bag material used to ship components. | 20950 units | 2009-09-01 |
| 2007-10-15 | Not classified | Environmental control | Foreign material: Glass fragments may present in the plastic bag material used to ship components. | 20950 units | 2009-09-01 |
| 2007-10-15 | Not classified | Environmental control | Foreign material: Glass fragments may present in the plastic bag material used to ship components. | 20950 units | 2009-09-01 |
| 2007-10-15 | Not classified | Environmental control | Foreign material: Glass fragments may present in the plastic bag material used to ship components. | 20950 units | 2009-09-01 |
| 2007-10-15 | Not classified | Environmental control | Foreign material: Glass fragments may present in the plastic bag material used to ship components. | 20950 units | 2009-09-01 |
| 2007-10-15 | Not classified | Environmental control | Foreign material: Glass fragments may present in the plastic bag material used to ship components. | 20950 units | 2009-09-01 |
| 2003-09-29 | Not classified | Other | product does not contain built in exhalation port | 5293 units | 2004-03-01 |
| 2003-09-29 | Not classified | Other | product does not contain built in exhalation port | 5293 units | 2004-03-01 |
| 2003-09-29 | Not classified | Other | product does not contain built in exhalation port | 5293 units | 2004-03-01 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.