Vocsn
Catalogue number V*Home, English, listed by Ventec Life Systems, Inc., United States, under Heater, Breathing System W/Wo Controller (Not Humidifier Or Nebulizer. 4 manufacturers in China are registered for this product code.
Who Else Makes It
All of them in Guangdong. 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Flexicare Medical (Dongguan) Ltd. | Dongguan | Guangdong | Contract manufacturer | 48 |
| Vincent Medical (Dong Guan) Manufacturing Co., Ltd. | Dong Guan | Guangdong | Contract manufacturer | 29 |
| Dongguan Plastiflex Hose Technology Ltd | Dongguan | Guangdong | Contract manufacturer | 3 |
| Guang Dong EDA Technology Co., Ltd. | Dongguan | Guangdong | Contract manufacturer | 6 |
Record
| Listed by | Ventec Life Systems, Inc., United States |
|---|---|
| FDA product code | BZE |
| Device type | Heater, Breathing System W/Wo Controller (Not Humidifier Or Nebulizer |
| Device class | Class 2 |
| Regulation | 21 CFR 868.5270 |
| Establishment | Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer |
| 510(k) | K162877 |
| Record published | 2023-06-30 |
| Record revised | 2025-12-10 (version 2) |
Specifications
| MRI safety | MR Unsafe |
|---|---|
| Prescription | Prescription only |
| Latex | Labelled latex-free |
| Label carries | manufacturing date, serial number |
| Storage | Storage environment humidity 0 to 90 % RH; Storage environment temperature -25 to 70 °C; Storage environment atmospheric pressure 50 to 110 KiloPascal |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| V*Home, English | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| AirLife™ | Airlife, Inc. | 110 |
| AirLife | Carefusion | 107 |
| Hudson RCI | Teleflex Medical LLC | 13 |
| Hybernite | Plastiflex Group NV | 11 |
| Fisher & Paykel Healthcare | Fisher & Paykel Healthcare, Ltd. | 10 |
| Hudson RCI | Medline Industries, Inc. | 10 |
| Hybernite RT | Plastiflex Group NV | 9 |
| Vocsn Patient Breathing Package | Ventec Life Systems, Inc. | 7 |
| Filter | Westmed, Inc. | 6 |
| Heater, Breathing System W/Wo Controller (Not Humidifier Or Nebulizer | Intersurgical Ltd. | 6 |
| F&P Evaqua 2 | Fisher & Paykel Healthcare, Ltd. | 4 |
| Circuits | Respironics Inc. | 4 |
Showing 12 of 56. All products under Heater, Breathing System W/Wo Controller (Not Humidifier Or Nebulizer
Recalls Naming This Product
5 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|---|---|
| Ventec Life Systems, Inc. | 510(k) number | 2026-05-08 | Class II | Vendor change control | Respiratory system intended to provide continuous/intermittent ventilator support, may have a damaged back-up battery supporting backup alarm function, which may result in the backup alarm not activating during loss of primary power and abs | 1 |
| Ventec Life Systems, Inc. | 510(k) number | 2026-03-25 | Class I | Process change control | Respiratory system intended to provide continuous/intermittent ventilator support, may not have been evaluated under all intended high-pressure conditions during production testing, so an oxygen leak condition could occur that may lead to r | 42 |
| Ventec Life Systems, Inc. | 510(k) number | 2025-02-03 | Class I | Component change control | Multi-Function Ventilators were serviced using incorrect parts which have the potential to cause unexpected shutdown, or when using an active circuit could result in inaccurate tidal volume monitor, not triggering on patient efforts, less i | 30 |
| Ventec Life Systems, Inc. | 510(k) number | 2024-01-09 | Class I | Process control | The bonded spiral wrap may detach before or during ventilation due to a manufacturing issue. Detachment of the spiral wrap can compromise structural integrity, functionality and/ or performance resulting in occlusions or leaks of the breat | 250 breathing circuits |
| Ventec Life Systems, Inc. | 510(k) number | 2021-05-10 | Class II | Device Design | Due to a component failure, ventilators may unexpectedly shut down or have a loss of blower function while in patient use. The shutdown potentially prevents the ventilator from providing ventilation therapy. | 1,934 devices (415 device that have not been updated) |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.