Breathing Circuit Set, Dual Limb

Dual limb breathing circuit set with Swivel Y-piece, neonatal flow sensor, neonatal expiratory valve set and pressure line for use with HAMILTON-C1/T1/MR1, 150 cm, neonatal, single-use

Registry build 21.09.26
33manufacturers in China registered for this device type
6catalogue numbers in this listing
1510(k) clearance
5recalls on this code

Who Else Makes It

Concentrated in Guangdong (14), Zhejiang (8), Jiangsu (3). 7 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code BZO
Manufacturer City Province Registered as Device types
Flexicare Medical (Dongguan) Ltd. Dongguan Guangdong Contract manufacturer 48
Well Lead Medical Co., Ltd. Guangzhou Guangdong Contract manufacturer 46
Vincent Medical (Dong Guan) Manufacturing Co., Ltd. Dong Guan Guangdong Contract manufacturer 29
Dongguan Plastiflex Hose Technology Ltd Dongguan Guangdong Contract manufacturer 3
Worldcross Industries Co., Ltd. Dong Yang Zhejiang Contract manufacturer 3
BMC(Dongguan) Medical Co., Ltd. Dongguan Guangdong Contract manufacturer 2
Guangzhou Schauenburg-Truplast Hose Technology Ltd. Guangzhou Guangdong Contract manufacturer 2
Boen Healthcare Co., Ltd. Suzhou Jiangsu Specification developer 263
Tiger Medical Group Shanghai Shanghai Specification developer 38
Hangzhou Weize IMP & EXP Co., Ltd. Hangzhou Zhejiang Manufacturer 34
GaleMed (Xiamen) Co., Ltd. Xiamen Fujian Contract manufacturer 33
Evereast Medical Products Group Co., Ltd. Changyuan Henan Contract manufacturer 30

Showing 12 of 33. All 33 manufacturers in China registered for Set, Tubing And Support, Ventilator (W Harness)

Record

Regulatory record for Breathing circuit set, dual limb
Listed by Hamilton Medical AG, Switzerland
FDA product code BZO
Device type Set, Tubing And Support, Ventilator (W Harness)
Device class Class 1
Regulation 21 CFR 868.5975
Establishment Contract manufacturer, Specification developer, Complaint-file establishment, Manufacturer, Exporter
Premarket notification Exempt
Record published 2022-12-08

Specifications

Specifications
MRI safety MR Safe
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date, manufacturing date
Packaging Pack of 10, pack of 20

Catalogue Numbers

Catalogue numbers for Breathing circuit set, dual limb
Catalogue number Size Status
260182 In distribution
260170 In distribution
260180 In distribution
260244 In distribution
260241 In distribution
260169 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Fisher & Paykel Healthcare Fisher & Paykel Healthcare, Ltd. 85
Hudson RCI Teleflex Medical LLC 82
Classic RT Plastiflex Group NV 63
INOmax Mallinckrodt Manufacturing LLC 37
AirLife™ Airlife, Inc. 26
Vadi Medical Vadi Medical Technology Co., Ltd. 17
Ventilator Circuit King Systems Corporation. 16
Wellead Oxygen Tubing Well Lead Medical Co., Ltd. 15
Gas Sampling Line Westmed, Inc. 15
Breathing circuit set, coaxial Hamilton Medical AG 14
Create Biotech Create Biotech Co., Ltd. 13
CPAP Tubing Exceleron Medical, LLC 10

Showing 12 of 356. All products under Set, Tubing And Support, Ventilator (W Harness)

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K945740 1995-03-23

Recalls

2 of these are Class I. Class I is the FDA’s most serious grade: a reasonable probability of serious injury or death. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2026-05-29 Class I Component design/selection Ventilator coaxial breathing circuit may have, expiratory valve sets with membranes sticking to valve body, not detectable during pre-operative test, which will result in “exhalation obstructed ” alarm, which may result in inadequate ventil 27,270 pcs
2025-06-26 Class I Process control Ventilator coaxial breathing circuit may have a crack in blue tubing, which is used to deliver fresh gas to the patient. The crack will compromise inspiratory and expiratory flows, leading to partial or complete rebreathing of exhaled gases 2,560
2015-06-01 Class II Device Design An issue has been discovered with the Hamilton Medical Infant Flow Sensor, single use. When a ventilation mode with adaptive volume control (APVcmv/CMV+) is used, the ventilator may adjust the ventilation on the inaccurate flow measurement 154 total – all part numbers 2015-08-12
2015-06-01 Class II Device Design An issue has been discovered with the Hamilton Medical Infant Flow Sensor, single use. When a ventilation mode with adaptive volume control (APVcmv/CMV+) is used, the ventilator may adjust the ventilation on the inaccurate flow measurement 154 total, all part numbers 2015-08-12
2015-06-01 Class II Device Design An issue has been discovered with the Hamilton Medical Infant Flow Sensor, single use. When a ventilation mode with adaptive volume control (APVcmv/CMV+) is used, the ventilator may adjust the ventilation on the inaccurate flow measurement 154 total, all part numbers 2015-08-12

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer