Invacare® Platinum® Mobile Oxygen Concentrator With 2nd Battery

Invacare POC1-100BA Platinum Mobile Oxygen Concentrator + 2Nd Battery

Registry build 21.09.26
22manufacturers in China registered for this device type
1catalogue number
20510(k) clearances naming this product code
4recalls on this code

Who Else Makes It

Concentrated in Jiangsu (6), Guangdong (5), Beijing (2). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code CAW
Manufacturer City Province Registered as Device types
Foshan Kycare Medical Equipment Co., Ltd. Foshan Guangdong Contract manufacturer 3
Jakamed Instruments Co., Ltd. Changsha Hunan Contract manufacturer 2
Jiangsu Jumao X-Care Medical Equipment Co., Ltd. Danyang Jiangsu Contract manufacturer 37
Beijing Choice Electronic Technololgy Co., Ltd. Beijing Beijing Repacker / relabeller 30
Jiangsu Yuyue Medical Equipment & Supply Company Limited Jiangsu Jiangsu Contract manufacturer 17
Tianjin Choice Medical Device Co., Ltd. Tianjin Tianjin Contract manufacturer 12
Danyang Huayi Medical Supply & Equipment Co., Ltd. Danyang Jiangsu Contract manufacturer 11
Shandong Moonlight Electronics Tech Co., Ltd. Weifang Shandong Manufacturer 11
Honsun (Nantong) Co., Ltd. Nantong Jiangsu Contract manufacturer 9
Beijing Choicemmed Technology Co., Ltd. Beijing Beijing Repacker / relabeller 9
Foshan Care Medical Technology Co., Ltd. Foshan Guangdong Manufacturer 3
Zhengzhou Olive Electronic Technology Co., Ltd. Zhengzhou Henan Manufacturer 3

Showing 12 of 22. All 22 manufacturers in China registered for Generator, Oxygen, Portable

Record

Regulatory record for Invacare® Platinum® Mobile Oxygen Concentrator with 2nd Battery
Listed by Invacare GmbH, Germany
FDA product code CAW
Device type Generator, Oxygen, Portable
Device class Class 2
Regulation 21 CFR 868.5440
Establishment Specification developer, Complaint-file establishment, Manufacturer
Record published 2024-04-10
Record revised 2026-02-06 (version 2)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only
Label carries serial number
Distribution end date 2024-12-31

Catalogue Numbers

Catalogue numbers for Invacare® Platinum® Mobile Oxygen Concentrator with 2nd Battery
Catalogue number Size Status
POC1-100BAAMZ Withdrawn

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
DeVilbiss DeVilbiss Healthcare LLC. 50
EverFlo Respironics Inc. 32
Mark 5 Nuvo Lite Nidek Medical Products, Inc. 30
SimplyGo Mini Respironics Inc. 26
X-PLO2R Belluscura, LLC 17
Mark 5 Nuvo 8 Nidek Medical Products, Inc. 12
ViveBreathe Vive Health LLC 11
Invacare® HomeFill® Oxygen System Invacare GmbH 11
Discov-R Belluscura, LLC 11
NewLife Elite Caire Inc. 10
NewLife Elite Airsep Corp. 10
Rhythm Healthcare Qingdao Kingon Medical Science AND Technology Co., Ltd. 9

Showing 12 of 187. All products under Generator, Oxygen, Portable

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K203210 2021-04-12
K200890 2020-08-06
K191159 2019-08-29
K160630 2016-09-27
K083751 2009-05-21
K071928 2007-12-12
K021685 2002-07-23
K020386 2002-07-02
K003939 2001-03-21
K983627 1999-10-22
K983777 1998-12-18
K924818 1993-08-06
K914488 1992-09-15
K904087 1990-10-26
K891488 1989-05-25
K851435 1985-07-29
K851434 1985-07-29
K851437 1985-07-29
K851439 1985-07-29
K851438 1985-07-29

Recalls

3 of these are Class II. Class II means a temporary or reversible health consequence. Class III is unlikely to cause harm at all → typically a labelling or documentation fault. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2022-06-10 Class III Labeling Change Control Between March 2, 2021 and December 31, 2021, the product label used in production did not contain the “Rx Only” statement as required. 179 devices
2020-10-30 Class II Device Design Breakdown of the sound abatement washer, and metal on metal wear inside the Pressure Equalization (P.E.) valve assembly in the concentrator may lead to failure that can result in self-extinguishing fires or cap explosions. 384,767 units 2024-12-31
2014-10-31 Class II Device Design The firm has found that the Component- Dianz Capacitor has ruptured which results in a potential fire hazard. 138,446 units distributed globally 2017-02-07
2014-09-23 Class II Process control It was determined that a defective sieve bed subassembly enabled zeolite sieve dust from the sieve beds to migrate into the valves of the manifold assembly and muffler causing a reduction in oxygen concentration. 5,963 2015-06-18

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer