Invacare® Supply Line Assembly With Coiled Tubing
Invacare 1105177 Supply Line Assembly with Coiled Tubing (12')
Who Else Makes It
Concentrated in Jiangsu (6), Guangdong (5), Beijing (2). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Foshan Kycare Medical Equipment Co., Ltd. | Foshan | Guangdong | Contract manufacturer | 3 |
| Jakamed Instruments Co., Ltd. | Changsha | Hunan | Contract manufacturer | 2 |
| Jiangsu Jumao X-Care Medical Equipment Co., Ltd. | Danyang | Jiangsu | Contract manufacturer | 37 |
| Beijing Choice Electronic Technololgy Co., Ltd. | Beijing | Beijing | Repacker / relabeller | 30 |
| Jiangsu Yuyue Medical Equipment & Supply Company Limited | Jiangsu | Jiangsu | Contract manufacturer | 17 |
| Tianjin Choice Medical Device Co., Ltd. | Tianjin | Tianjin | Contract manufacturer | 12 |
| Danyang Huayi Medical Supply & Equipment Co., Ltd. | Danyang | Jiangsu | Contract manufacturer | 11 |
| Shandong Moonlight Electronics Tech Co., Ltd. | Weifang | Shandong | Manufacturer | 11 |
| Honsun (Nantong) Co., Ltd. | Nantong | Jiangsu | Contract manufacturer | 9 |
| Beijing Choicemmed Technology Co., Ltd. | Beijing | Beijing | Repacker / relabeller | 9 |
| Foshan Care Medical Technology Co., Ltd. | Foshan | Guangdong | Manufacturer | 3 |
| Zhengzhou Olive Electronic Technology Co., Ltd. | Zhengzhou | Henan | Manufacturer | 3 |
Showing 12 of 22. All 22 manufacturers in China registered for Generator, Oxygen, Portable
Record
| Listed by | Invacare GmbH, Germany |
|---|---|
| FDA product code | CAW |
| Device type | Generator, Oxygen, Portable |
| Device class | Class 2 |
| Regulation | 21 CFR 868.5440 |
| Establishment | Specification developer, Complaint-file establishment, Manufacturer |
| 510(k) | K020386 |
| Record published | 2024-04-10 |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Prescription | Prescription only |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 1105177 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| DeVilbiss | DeVilbiss Healthcare LLC. | 50 |
| EverFlo | Respironics Inc. | 32 |
| Mark 5 Nuvo Lite | Nidek Medical Products, Inc. | 30 |
| SimplyGo Mini | Respironics Inc. | 26 |
| X-PLO2R | Belluscura, LLC | 17 |
| Mark 5 Nuvo 8 | Nidek Medical Products, Inc. | 12 |
| ViveBreathe | Vive Health LLC | 11 |
| Invacare® HomeFill® Oxygen System | Invacare GmbH | 11 |
| Discov-R | Belluscura, LLC | 11 |
| NewLife Elite | Caire Inc. | 10 |
| NewLife Elite | Airsep Corp. | 10 |
| Rhythm Healthcare | Qingdao Kingon Medical Science AND Technology Co., Ltd. | 9 |
Showing 12 of 187. All products under Generator, Oxygen, Portable
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K203210 | 2021-04-12 |
| K200890 | 2020-08-06 |
| K191159 | 2019-08-29 |
| K160630 | 2016-09-27 |
| K083751 | 2009-05-21 |
| K071928 | 2007-12-12 |
| K021685 | 2002-07-23 |
| K020386 | 2002-07-02 |
| K003939 | 2001-03-21 |
| K983627 | 1999-10-22 |
| K983777 | 1998-12-18 |
| K924818 | 1993-08-06 |
| K914488 | 1992-09-15 |
| K904087 | 1990-10-26 |
| K891488 | 1989-05-25 |
| K851435 | 1985-07-29 |
| K851434 | 1985-07-29 |
| K851437 | 1985-07-29 |
| K851439 | 1985-07-29 |
| K851438 | 1985-07-29 |
Recalls Naming This Product
2 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Invacare GmbH | 510(k) number | 2014-10-31 | Class II | Device Design | The firm has found that the Component- Dianz Capacitor has ruptured which results in a potential fire hazard. | 138,446 units distributed globally | 2017-02-07 |
| Invacare GmbH | 510(k) number | 2014-09-23 | Class II | Process control | It was determined that a defective sieve bed subassembly enabled zeolite sieve dust from the sieve beds to migrate into the valves of the manifold assembly and muffler causing a reduction in oxygen concentration. | 5,963 | 2015-06-18 |
Recalls
1 of these is Class II. Class II means a temporary or reversible health consequence. Class III is unlikely to cause harm at all → typically a labelling or documentation fault. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2022-06-10 | Class III | Labeling Change Control | Between March 2, 2021 and December 31, 2021, the product label used in production did not contain the “Rx Only” statement as required. | 179 devices | |
| 2020-10-30 | Class II | Device Design | Breakdown of the sound abatement washer, and metal on metal wear inside the Pressure Equalization (P.E.) valve assembly in the concentrator may lead to failure that can result in self-extinguishing fires or cap explosions. | 384,767 units | 2024-12-31 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.