StimuLong Sono NanoLine
StimuLong Sono NanoLine is a regional anesthesia kit containing a cannula and a catheter for delivering local anesthetic. The components provide access through tissue and a route for…
StimuLong Sono NanoLine is a regional anesthesia kit containing a cannula and a catheter for delivering local anesthetic. The components provide access through tissue and a route for single-injection or continuous regional anesthesia and analgesia. The kit is supplied sterile for single use.
The Sono cannula uses the CornerStone surface technique to improve visibility under ultrasound. The Sono catheter contains an inner coil that improves ultrasound visibility and stability. Electrical stimulation can be applied through the cannula or catheter tip using the appropriate cable and connector to help locate the intended area.
Listed Item
StimuLong Sono NanoLine® PlexoLong NanoLine® cannula UP 19G x 100 StimuLong Sono catheter 20G x 50cm with
Component Roles
The cannula provides the puncture route, while the catheter conducts anesthetic. Sono-Series kits may include accessories such as an adapter, syringe or filter, depending on the configuration.
Who Else Makes It
Registered in Jiangsu.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Jiangsu Caina Medical Co., Ltd. | Jiangyin | Jiangsu | Contract manufacturer | 20 |
Record
| Listed by | Pajunk Gmbh Medizintechnologie, Germany |
|---|---|
| FDA product code | CAZ |
| Device type | Anesthesia Conduction Kit |
| Device class | Class 2 |
| Regulation | 21 CFR 868.5140 |
| Establishment | Contract manufacturer, Specification developer, Repacker / relabeller, Private-label distributor, Complaint-file establishment, Manufacturer |
| 510(k) | K113188 |
| Record published | 2016-09-09 |
| Record revised | 2025-12-01 (version 6) |
Specifications
| MRI safety | MR Unsafe |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Supplied as a kit | Yes |
| Latex | Labelled latex-free |
| Label carries | lot or batch number, expiry date, manufacturing date |
| Storage | Storage environment temperature 10 to 30 °C; Storage environment humidity 20 to 65 % RH |
| Packaging | Pack of 10 |
| Distribution end date | 2025-03-15 |
Catalogue Numbers
| Catalogue number | Size | Per pack | Status |
|---|---|---|---|
| 531157-32A | In distribution | ||
| 521157-32C | In distribution | ||
| 531157-32B | In distribution | ||
| 521157-32A | In distribution | ||
| 531157-32C | In distribution | ||
| 531157-32C | 10 | Withdrawn | |
| 521157-32C | 10 | Withdrawn | |
| 521157-32A | 10 | Withdrawn | |
| 511157-32A | 10 | Withdrawn | |
| 521157-32B | 10 | Withdrawn | |
| 531157-32B | 10 | Withdrawn | |
| 531157-32A | 10 | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Portex | ICU Medical, Inc | 1,340 |
| Arrow | Teleflex Medical LLC | 508 |
| Halyard | Avanos Medical, Inc. | 422 |
| Avanos | Avanos Medical, Inc. | 315 |
| Busse Hospital Disposables | Robert Busse & Co., Inc. | 215 |
| Integra® | Integra Pain Management | 181 |
| Epilong | Pajunk Gmbh Medizintechnologie | 79 |
| BD Perisafe, BD Epilor, BD Luer-Lok | Becton, Dickinson AND Company | 44 |
| Temena | Temena GmbH | 44 |
| BD Luer-Lok, BD Glaspak | Becton, Dickinson AND Company | 36 |
| Contiplex® | B. Braun Medical Inc. | 34 |
| Stimulong Sono | Pajunk Gmbh Medizintechnologie | 27 |
Showing 12 of 109. All products under Anesthesia Conduction Kit
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K202699 | 2020-12-29 |
| K190345 | 2019-05-16 |
| K113188 | 2012-03-01 |
| K082183 | 2008-10-28 |
| K082164 | 2008-10-27 |
| K062902 | 2007-06-07 |
| K062900 | 2007-01-12 |
| K060311 | 2006-06-13 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.