Ankor Endobronchial Tube
The ANKOR endobronchial tube is a double-lumen tube for differential ventilation. The FDA summary lists ABC35L among its named models. The filing says the tube is used for endobronchial…
The ANKOR endobronchial tube is a double-lumen tube for differential ventilation. The FDA summary lists ABC35L among its named models.
The filing says the tube is used for endobronchial intubation and allows selective inflation or deflation of either lung.
Role and Configuration
The ANKOR design has two cuff configurations: ABC models include an additional ANKOR cuff, while HBC models do not.
The stated uses include thoracic surgery, bronchospirometry, and endobronchial anesthesia, as well as other uses requiring endobronchial intubation.
Who Else Makes It
Concentrated in Guangdong (2), Henan (1), Zhejiang (1). One is registered as a contract manufacturer, able to build to a specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Well Lead Medical Co., Ltd. | Guangzhou | Guangdong | Contract manufacturer | 46 |
| Shenzhen Insighters Medical Technology Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 10 |
| Henan Tuoren Medical Device Co., Ltd. | Changyuan | Henan | Manufacturer | 5 |
| Hangzhou Tappa Medical Technology Co., Ltd. | Hangzhou | Zhejiang | Manufacturer | 3 |
Record
| Listed by | Insung Medical Co., Ltd., South Korea |
|---|---|
| FDA product code | CBI |
| Device type | Tube, Tracheal/Bronchial, Differential Ventilation (W/Wo Connector) |
| Device class | Class 2 |
| Regulation | 21 CFR 868.5740 |
| Establishment | Manufacturer |
| 510(k) | K200968 |
| Record published | 2025-04-29 |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Label carries | lot or batch number, expiry date |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| ABC35L | In distribution | |
| ABC33L | In distribution | |
| ABC35R | In distribution | |
| ABC37L | In distribution | |
| ABC37R | In distribution | |
| ABC39R | In distribution | |
| ABC39L | In distribution | |
| ABC33R | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Insighters | Shenzhen Insighters Medical Technology Co., Ltd. | 39 |
| Rusch | Teleflex Medical LLC | 26 |
| Univent Tube (TCB Type) | Fuji Systems Corp. | 22 |
| Hudson RCI | Teleflex Medical LLC | 21 |
| Sheridan | Teleflex Medical LLC | 19 |
| Tube, Tracheal/Bronchial, Differential Ventilation (W/Wo Connector) | Henan Tuoren Medical Device Co., Ltd. | 18 |
| Parker Flex-Tip | Salter Labs | 18 |
| Parker | Salter Labs | 17 |
| Tube, Tracheal/Bronchial, Differential Ventilation (W/Wo Connector) | Hangzhou Tappa Medical Technology Co., Ltd. | 12 |
| Forsure | Forsure Medical Products LLC. | 12 |
| Endobronchial Tube | Well Lead Medical Co., Ltd. | 12 |
| Portex | ICU Medical, Inc | 11 |
Showing 12 of 29. All products under Tube, Tracheal/Bronchial, Differential Ventilation (W/Wo Connector)
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K200968 | 2020-12-28 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.