LTV
Patient Circuit, W/O PEEP, 15mm, SPU, Single Heated Wire, F&P
Who Else Makes It
Concentrated in Guangdong (4), Jiangsu (2), Fujian (1). 6 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| GaleMed (Xiamen) Co., Ltd. | Xiamen | Fujian | Contract manufacturer | 33 |
| Vincent Medical (Dong Guan) Manufacturing Co., Ltd. | Dong Guan | Guangdong | Contract manufacturer | 29 |
| Sanmina | Kunshan | Jiangsu | Contract manufacturer | 15 |
| Mehow Innovative (Huizhou) Ltd. | Huizhou | Guangdong | Contract manufacturer | 11 |
| Respironics Medical Products (Shenzhen) Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 8 |
| Beijing Aeonmed Co., Ltd. | Sanhe | Hebei | Contract manufacturer | 7 |
| Shenzhen Mindray BIO-Medical Electronics Co., Ltd. | Shenzhen | Guangdong | Specification developer | 61 |
| GE Medical Systems (China) Co., Ltd. | Wuxi | Jiangsu | Contract manufacturer | 57 |
Record
| Listed by | Vyaire Medical, Inc., United States |
|---|---|
| FDA product code | CBK |
| Device type | Ventilator, Continuous, Facility Use |
| Device class | Class 2 |
| Regulation | 21 CFR 868.5895 |
| 510(k) | K101643 |
| Record published | 2024-08-12 |
| Record revised | 2026-05-18 (version 5) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Single use | Yes |
| Prescription | Prescription only |
| Supplied as a kit | Yes |
| Label carries | lot or batch number, expiry date, manufacturing date, serial number |
| Storage | Storage environment temperature -20 to 60 °C |
| Packaging | Case of 10, pack of 10, case of 5, case of 50, pack of 5 |
| Distribution end date | 2024-08-31 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 15090-104 | In distribution | |
| 29699-001 | In distribution | |
| 10779 | In distribution | |
| 10695 | In distribution | |
| 29701-001 | In distribution | |
| 21180-001 | In distribution | |
| 15090-103 | In distribution | |
| 19222-201 | In distribution | |
| 10800 | In distribution | |
| 29698-001 | In distribution | |
| 26618-001 | In distribution | |
| 29657-001 | In distribution | |
| 29660-001 | In distribution | |
| 14859-001 | In distribution | |
| 10130 | In distribution | |
| 19102-001 | In distribution | |
| 24555-001 | In distribution | |
| 10819×10 | In distribution | |
| 18172-001 | In distribution | |
| 19103-001 | In distribution | |
| 18221-101 | In distribution | |
| 29658-001 | In distribution | |
| 29695-001 | In distribution | |
| 11872×10 | In distribution | |
| 10818×10 | In distribution | |
| 18929-001 | In distribution | |
| 29700-001 | In distribution | |
| 11450 | In distribution | |
| 19333-201 | In distribution | |
| 19189-001 | In distribution | |
| 29715-001 | In distribution | |
| 15091-103 | In distribution | |
| 29702-001 | In distribution | |
| 29660-001 | In distribution | |
| 10821×10 | In distribution | |
| 15091-104 | In distribution | |
| 29710-001 | In distribution | |
| 15090-102 | In distribution | |
| 11454 | In distribution | |
| 29663-001 | In distribution | |
| 11505×10 | In distribution | |
| 10611 | In distribution | |
| 11581-G | In distribution | |
| 10700 | In distribution | |
| 10822×10 | In distribution | |
| 29665-001 | In distribution | |
| 10696 | In distribution | |
| 10823×10 | In distribution | |
| 19096-001 | In distribution | |
| 14982-001 | In distribution | |
| 15090-101 | In distribution | |
| 29701-001 | In distribution | |
| 10611 | In distribution | |
| 22770-001 | In distribution | |
| 10696 | In distribution | |
| 15091-102 | In distribution | |
| 11558×10 | In distribution | |
| 29697-001 | In distribution | |
| 29659-001 | In distribution | |
| 18093-001 | In distribution | |
| 14858-001 | In distribution | |
| 29696-001 | In distribution | |
| 17527-001 | In distribution | |
| 11451 | In distribution | |
| 15091-101 | In distribution | |
| 11872×10 | In distribution | |
| 11452 | In distribution | |
| 18888-001 | In distribution | |
| 17650-001 | In distribution | |
| 10820×10 | In distribution | |
| 29662-001 | In distribution | |
| 11455 | In distribution | |
| 11453 | In distribution | |
| 19444-001 | In distribution | |
| 10694 | In distribution | |
| 17475-001 | In distribution | |
| 11475 | In distribution | |
| 18941-001 | In distribution | |
| 29703-001 | In distribution | |
| 18930-001 | In distribution | |
| 21102-001 | In distribution | |
| 15091-102 | Withdrawn | |
| 29658-001 | Withdrawn | |
| 15090-104 | Withdrawn | |
| 29665-001 | Withdrawn | |
| 14858-001 | Withdrawn | |
| 14859-001 | Withdrawn | |
| 15091-104 | Withdrawn | |
| 29659-001 | Withdrawn | |
| 29662-001 | Withdrawn | |
| 15090-102 | Withdrawn | |
| 29663-001 | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Puritan Bennett | Covidien LP | 285 |
| Newport | Newport Medical Instruments, Inc. | 103 |
| Ventilator, Continuous, Facility Use | Hans Rudolph, Inc. | 66 |
| Infant Flow SiPAP | Carefusion | 62 |
| Avea | Carefusion | 57 |
| Ventoux | Flight Medical Innovations Ltd. | 48 |
| Trilogy | Respironics Inc. | 42 |
| Avea™ | Vyaire Medical, Inc. | 39 |
| Patient Circuits | Zoll Medical Corporation | 38 |
| Performatrak | Respironics Inc. | 35 |
| Bio-Med Devices, Inc. | BIO-MED Devices, Inc. | 34 |
| Vent | Zoll Medical Corporation | 32 |
Showing 12 of 419. All products under Ventilator, Continuous, Facility Use
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K201082 | 2021-11-10 |
Recalls
1 of these is Class I. Class I is the FDA’s most serious grade: a reasonable probability of serious injury or death. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2023-05-05 | Class II | Nonconforming Material/Component | Vyaire Medical identified two patient safety risks during the use of the bellavista 1000 and bellavista 1000e: 1. Under certain conditions of use, the touchscreen may become unresponsive and the device application stops responding (APP Hang | 910 units | |
| 2023-05-05 | Class II | Nonconforming Material/Component | Vyaire Medical identified two patient safety risks during the use of the bellavista 1000 and bellavista 1000e: 1. Under certain conditions of use, the touchscreen may become unresponsive and the device application stops responding (APP Hang | 392 units | |
| 2021-12-20 | Class I | Software change control | Potential cessation in ventilation can occur under specific conditions. | 4189 units | 2024-08-28 |
| 2019-11-25 | Class II | Software design | The G6 bellavista 1000 US ventilators may experience intermittent failures: Lack of acoustic high priority alarm, presence of a ‘no alarm’ condition, or presence of non-responsive touch screen. | 116 | 2023-08-08 |