BE 130 One-Way Valve
The reusable BE 130 One-Way Valve is designed for use in any breathing circuit or ventilatory system where "back flow" must be avoided. It is designed to prevent the flow of gas back toward…
The reusable BE 130 One-Way Valve is designed for use in any breathing circuit or ventilatory system where “back flow” must be avoided. It is designed to prevent the flow of gas back toward the source.
Who Else Makes It
Concentrated in Guangdong (6), Fujian (6), Jiangsu (2). 6 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Saferlife Products Co., Ltd. | Guangzhou | Guangdong | Contract manufacturer | 58 |
| GaleMed (Xiamen) Co., Ltd. | Xiamen | Fujian | Contract manufacturer | 33 |
| Polymed (Xiamen) Plastic Industrial Co., Ltd. | Xiamen | Fujian | Contract manufacturer | 17 |
| Hangzhou Jinlin Medical Appliances Co., Ltd. | Hangzhou | Zhejiang | Contract manufacturer | 11 |
| Flying Tooling Engineering Limited | Dongguan | Guangdong | Contract manufacturer | 9 |
| Xiamen Tianzuo Medical Co., Ltd. | Xiamen | Fujian | Contract manufacturer | 4 |
| Dongguan City Ruimi Gift Products Co Ltd | Dongguan | Guangdong | Repacker / relabeller | 62 |
| Firstar Healthcare Company Limited (Guangzhou) | Guangzhou | Guangdong | Contract manufacturer | 57 |
| Nanjing J SUN Healthcare Co., Ltd. | Nanjing | Jiangsu | Repacker / relabeller | 56 |
| Xiamen Firstcare IMP. & EXP. Co., Ltd. | Xiamen | Fujian | Exporter | 40 |
| Bestreat Safety & First AID Solution Co., Ltd. | Wuhan | Hubei | Manufacturer | 35 |
| Heaven Healthcare Co., Ltd. | Shaoxing | Zhejiang | Private-label distributor | 33 |
Showing 12 of 19. All 19 manufacturers in China registered for Valve, Non-Rebreathing
Record
| Listed by | Instrumentation Industries, Incorporated, United States |
|---|---|
| FDA product code | CBP |
| Device type | Valve, Non-Rebreathing |
| Device class | Class 2 |
| Regulation | 21 CFR 868.5870 |
| Establishment | Contract manufacturer, Specification developer, Repacker / relabeller, Manufacturer |
| 510(k) | K970780 |
| Record published | 2015-10-24 |
| Record revised | 2018-07-06 (version 3) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Sterilisation | Radiation Sterilization, High-level Disinfectant, Ethylene Oxide |
| Prescription | Prescription only |
| Latex | Labelled latex-free |
| Label carries | lot or batch number |
| Packaging | Pack of 10 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| BE 130 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Valve, Non-Rebreathing | Hans Rudolph, Inc. | 139 |
| Microtek | Microtek Medical LLC | 40 |
| Curaplex | Bound Tree Medical, LLC | 39 |
| Valve, Non-Rebreathing | Intersurgical Ltd. | 17 |
| Compower | Xiamen Compower Medical Tech. Co., Ltd. | 16 |
| LSP | Allied Medical LLC | 11 |
| Top Safety | Foremount Enterprise Co., Ltd. | 10 |
| WNL | Foremount Enterprise Co., Ltd. | 10 |
| Aero US | Foremount Enterprise Co., Ltd. | 8 |
| WNL product | Xiamen Compower Medical Tech. Co., Ltd. | 6 |
| Kemp USA | Foremount Enterprise Co., Ltd. | 6 |
| 2700 Nrbv | Hans Rudolph, Inc. | 5 |
Showing 12 of 231. All products under Valve, Non-Rebreathing
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K983631 | 1999-07-01 |
| K980725 | 1998-08-24 |
| K973066 | 1998-02-03 |
| K970780 | 1997-09-18 |
| K810348 | 1981-02-23 |
| K770629 | 1977-05-23 |
| K770627 | 1977-05-23 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.