McGRATH MAC

Disposable Laryngoscope Blade 2

Registry build 21.09.26
44manufacturers in China registered for this device type
32catalogue numbers in this listing

Who Else Makes It

Concentrated in Guangdong (22), Jiangsu (9), Zhejiang (7). 8 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code CCW
Manufacturer City Province Registered as Device types
Flexicare Medical (Dongguan) Ltd. Dongguan Guangdong Contract manufacturer 48
Hangzhou Fushan Medical Appliance Co., Ltd. Hangzhou Zhejiang Contract manufacturer 44
Modern Medical Equipment Manufacturing Ltd. Heng Li, Dongguan Guangdong Contract manufacturer 26
Forefront Medical Technology (Jiangsu) Co., Ltd. Changzhou Jiangsu Contract manufacturer 14
Ambu Limited Xiang Yu F.T.Z., Xiamen Fujian Contract manufacturer 11
Shenzhen Insighters Medical Technology Co., Ltd. Shenzhen Guangdong Contract manufacturer 10
Dongguan Honfield Precision Parts Co., Ltd. Zhangmutou, Dongguan Guangdong Contract manufacturer 8
MediConcepts Technology (Shenzhen) Company Limited Shenzhen Guangdong Contract manufacturer 5
Boen Healthcare Co., Ltd. Suzhou Jiangsu Specification developer 263
Shanghai Medical Instruments (Group) Ltd. Corp. Shanghai Shanghai Contract manufacturer 235
Suzhou Meccan Import and Export Corp. Suzhou Jiangsu Contract manufacturer 71
Saferlife Products Co., Ltd. Guangzhou Guangdong Contract manufacturer 58

Showing 12 of 44. All 44 manufacturers in China registered for Laryngoscope, Rigid

Record

Regulatory record for McGRATH MAC
Listed by Covidien LP, United States
FDA product code CCW
Device type Laryngoscope, Rigid
Device class Class 1
Regulation 21 CFR 868.5540
Premarket notification Exempt
Record published 2025-04-27
Record revised 2026-04-28 (version 15)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Latex Labelled latex-free
Label carries lot or batch number, expiry date, manufacturing date, serial number
Storage Special storage condition: Fragile, Keep dry, Stacking limitations, This side up; Storage environment temperature 14 to 158 °F
Packaging Pack_or_inner_pack of 50, case of 10, pack_or_inner_pack of 10, case of 30, pack_or_inner_pack of 20, case of 50

Catalogue Numbers

Catalogue numbers for McGRATH MAC
Catalogue number Size Status
350-017-000 In distribution
350-005-000 In distribution
301-000-000 In distribution
350-088-000 In distribution
350-013-000 In distribution
350-072-000 In distribution
350-072-000 In distribution
301-000-000 In distribution
350-082-000 In distribution
350-086-000 In distribution
350-084-000 In distribution
350-013-000 In distribution
350-013-000 In distribution
350-005-000 In distribution
350-013-000 In distribution
302-000-000 In distribution
302-000-000 In distribution
DL300-000-000 In distribution
350-072-000 In distribution
350-086-000 In distribution
350-017-000 In distribution
350-017-000 In distribution
350-005-000 In distribution
350-072-000 In distribution
350-084-000 In distribution
350-005-000 In distribution
300-000-000 In distribution
350-017-000 In distribution
350-088-000 In distribution
350-013-000 In distribution
350-082-000 In distribution
350-005-000 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Rusch Teleflex Medical LLC 509
SunMed SunMed Group Holdings, LLC 255
Ambler Surgical Ambler Surgical, LLC 192
AincA® Anesthesia Associates, Inc. 186
Curaplex Bound Tree Medical, LLC 172
GlideScope® Verathon Medical (Canada) ULC 166
Pilling Teleflex Medical LLC 163
Carnegie Surgical LLC Carnegie Surgical LLC 157
Laryngoscope, Rigid Karl Storz GmbH & Co. KG 140
Medline Medline Industries, Inc. 128
Millennium Avalign Technologies, Inc. 111
Sklar® Sklar Corporation 92

Showing 12 of 442. All products under Laryngoscope, Rigid

Recalls Naming This Product

4 recalls name this product by its own identifiers, the UDI on its label.

Recalls naming the identifiers of McGRATH MAC
Recalled by Identified by Initiated FDA class Root cause Reason Quantity
Covidien UDI-DI 2024-07-09 Class I Device Design Battery management system within Laryngoscope devices may deplete below the deign threshold which may result in thermal event followed by risk of explosion. 75,544 units
Covidien UDI-DI 2023-09-28 Class I Process control Defective video laryngoscopes that did not pass quality tests established for the product, that were designated for destruction, were stolen, and subsequently distributed for sale. Defective device use may result in failed laryngoscopy and/ 5709
Covidien UDI-DI 2023-08-10 Class II Under Investigation by firm Laryngoscope blades may contain an ineffective application of anti-fog agent which may result in condensation accumulating causing the screen to be blurred or obscured. 42,367
Covidien UDI-DI 2023-08-10 Class II Under Investigation by firm Laryngoscope blades may contain an ineffective application of anti-fog agent which may result in condensation accumulating causing the screen to be blurred or obscured. 42,367

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer