BiPAP Avaps

BiPAP AVAPS C Series is a blower-based ventilatory support system that delivers positive airway pressure through a patient circuit and mask. Its bilevel modes alternate between inspiratory…

Registry build 21.09.26

BiPAP AVAPS C Series is a blower-based ventilatory support system that delivers positive airway pressure through a patient circuit and mask. Its bilevel modes alternate between inspiratory and expiratory pressure levels, while CPAP mode maintains a fixed pressure.

The system includes a microprocessor-controlled flow generator, an integrated heated humidifier and a display for therapy settings and clinical data. Device alarms alert the user to conditions affecting ventilation.

Listed Item

BiPAP AVAPS C Series Ventilatory Support System, 25 cm, International

Optional Oximetry

With the oximetry module connected, the system records pulse-oximetry and treatment data during therapy. The accessory includes an oximeter sensor, cable and communication module. Data are stored on a removable SD card for clinician review. Ventilator alarms are separate from oximetry measurements.

6manufacturers in China registered for this device type
35catalogue numbers in this listing
12510(k) clearances naming this product code
20recalls on this code

Who Else Makes It

Concentrated in Guangdong (4), Beijing (1), Tianjin (1). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code MNS
Manufacturer City Province Registered as Device types
Modern Medical Equipment Manufacturing Ltd. Heng Li, Dongguan Guangdong Contract manufacturer 26
Respironics Medical Products (Shenzhen) Co., Ltd. Shenzhen Guangdong Contract manufacturer 8
BMC (Tianjin) Medical Co., Ltd. Wuqing District Tianjin Contract manufacturer 3
Huizhou RSP Technology Co., Ltd. Huizhou Guangdong Contract manufacturer 3
Modern Medical Equipment Manufacturing (Qing Yuan) Ltd Qing Yuan Guangdong Contract manufacturer 26
BMC Medical Co., Ltd. Fengtai District Beijing Specification developer 3

Record

Regulatory record for BiPAP Avaps
Listed by Respironics Inc., United States
FDA product code MNS
Device type Ventilator, Continuous, Non-Life-Supporting
Device class Class 2
Regulation 21 CFR 868.5895
Establishment Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter
510(k) K102465
Record published 2017-01-13
Record revised 2022-10-24 (version 6)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only
Label carries serial number
Storage Storage environment temperature -4 to 140 °F; Storage environment humidity 15 to 95 % RH; Storage environment temperature -20 to 60 °C
Packaging Multipack of 4
Distribution end date 2023-07-13

Catalogue Numbers

Catalogue numbers for BiPAP Avaps
Catalogue number Size Status
BiPAP AVAPS C Series, 30cm, FI In distribution
00 In distribution
BiPAP AVAPS C Series Core Pack, AHP In distribution
BiPAP AVAPS C Series, 30cm, FR In distribution
BiPAP AVAPS C Series, AHP In distribution
BiPAP AVAPS C Series Core Pack w/Heated Tube, AHP In distribution
00 In distribution
00 In distribution
BiPAP AVAPS C Series Sapio Belife In distribution
00 In distribution
BiPAP AVAPS C Series, 30CM, ND In distribution
BiPAP AVAPS C Series, Vitalvent EVO In distribution
BiPAP AVAPS C Series, 30CM, ES In distribution
BiPAP AVAPS C Series, 30cm, INTL In distribution
BiPAP AVAPS C Series, 30cm, PT In distribution
BiPAP AVAPS C Series, Synchrony In distribution
BiPAP AVAPS C Series, 25cm, AU In distribution
BiPAP AVAPS C Series, 30cm, CA In distribution
BiPAP AVAPS C Series, 30cm, NO In distribution
00 In distribution
BiPAP AVAPS C Series, 30cm, GB In distribution
00 In distribution
00 In distribution
BiPAP AVAPS C Series, 30cm, SE In distribution
BiPAP AVAPS C Series, Private Label, 30cm, INTL Withdrawn
BiPAP AVAPS C Series, 30cm, CN Withdrawn
BiPAP AVAPS C Series, 30cm, US Withdrawn
BiPAP AVAPS C Series Core Pack w/Heated Tube, 30cm, CN Withdrawn
BiPAP AVAPS C Series, IT Withdrawn
BiPAP AVAPS C Series Core Pack, Heated Tube, 30cm, CA Withdrawn
BiPAP AVAPS C Series Core Pack, 30cm, US Withdrawn
BIPAP AVAPS C Series, 30cm, AU Withdrawn
BiPAP AVAPS C Series Core Pack w/Heated Tube, 30cm, US Withdrawn
BiPAP AVAPS C Series, 25cm, INTL Withdrawn
BiPAP AVAPS C Series Core Pack, 30cm, CN Withdrawn

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
DreamStation Respironics Inc. 144
AF531 Respironics Inc. 53
BiPAP autoSV Advanced System One 60 Series Respironics Inc. 44
DreamStation BiPAP Avaps Respironics Inc. 30
DreamMapper Respironics Inc. 27
BiPAP A30 Respironics Inc. 25
BiPAP S/T C-Series Respironics Inc. 19
OmniLab Advanced Plus Respironics Inc. 19
EncoreAnywhere Respironics Inc. 17
DeVilbiss DeVilbiss Healthcare LLC. 15
Ventilator, Continuous, Non-Life-Supporting Salter Labs 12
DreamStation BiPAP autoSV Respironics Inc. 12

Showing 12 of 73. All products under Ventilator, Continuous, Non-Life-Supporting

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K113053 2012-02-01
K102465 2011-03-24
K101130 2010-09-02
K092818 2010-01-22
K092043 2009-08-05
K063540 2007-02-22
K063533 2007-02-20
K031656 2003-07-30
K020777 2002-03-20
K012323 2001-12-20
K992530 2000-03-20
K984407 1999-05-19

Recalls Naming This Product

1 recall names this product by its own identifier, the 510(k) it is cleared under.

Recalls naming the identifiers of BiPAP Avaps
Recalled by Identified by Initiated FDA class Root cause Reason Quantity
Respironics Inc. 510(k) number 2021-06-14 Class I Device Design The polyester-based polyurethane (PE-PUR) foam may degrade into particles which may enter the device s the air pathway and be ingested or inhaled by the user, and the PE-PUR foam may off-gas certain chemicals. 15,357,775 (10,307,186 in US, 5,039,748 OUS) in total

Recalls

14 of these are Class I. Class I is the FDA’s most serious grade: a reasonable probability of serious injury or death. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2025-05-09 Class I Device Design This device does not indicate for use in patients with respiratory failure. 5,958 units
2025-05-09 Class I Device Design This device does not indicate for use in patients with respiratory failure. 3 units in US 22,416 units and 49 units OUS
2024-04-01 Class I Device Design Device may experience an interruption or loss of therapy in case of a Ventilator Inoperative alarm. This may lead to hypoventilation, mild to severe hypoxemia, hypercarbia, respiratory failure/insufficiency, or potentially death. 9,388 US; 2,664 ROW
2024-03-26 Class I Device Design Potential for devices to experience interruption/loss of therapy during a Ventilator Inoperative alarm. This may lead to hypoventilation, mild to severe hypoxemia, hypercarbia, respiratory failure/insufficiency, or potentially death in the 3 US; 21,414 OUS
2024-03-26 Class I Device Design Potential for devices to experience interruption/loss of therapy during a Ventilator Inoperative alarm. This may lead to hypoventilation, mild to severe hypoxemia, hypercarbia, respiratory failure/insufficiency, or potentially death in the 5,958 US; None OUS
2022-08-26 Class I Process control Motor assemblies manufactured with nonconforming plastic that contributes to off-gassing of VOCs. 85 units
2022-08-26 Class I Process control Motor assemblies manufactured with nonconforming plastic that contributes to off-gassing of VOCs. 34 units ***updated January 2024 *** additional 3 units
2022-08-26 Class I Process control Motor assemblies manufactured with nonconforming plastic that contributes to off-gassing of VOCs. 295 units
2022-08-26 Class I Process control Motor assemblies manufactured with nonconforming plastic that contributes to off-gassing of VOCs. 1,091 units ***updated Jan 2024*** additional 323 units
2022-08-26 Class I Process control Motor assemblies manufactured with nonconforming plastic that contributes to off-gassing of VOCs. 8 units
2022-08-26 Class I Process control Motor assemblies manufactured with nonconforming plastic that contributes to off-gassing of VOCs. 146 units ***updated January 2024*** 30 additional units
2021-06-14 Class I Device Design The polyester-based polyurethane (PE-PUR) foam may degrade into particles which may enter the devices air pathway and be ingested or inhaled by the user, and the PE-PUR foam may off-gas certain chemicals. 8047
2021-06-14 Class I Device Design The polyester-based polyurethane (PE-PUR) foam may degrade into particles which may enter the device s the air pathway and be ingested or inhaled by the user, and the PE-PUR foam may off-gas certain chemicals. 15,357,775 (10,307,186 in US, 5,039,748 OUS) in total
2021-06-14 Class I Device Design The polyester-based polyurethane (PE-PUR) foam may degrade into particles which may enter the devices air pathway and be ingested or inhaled by the user, and the PE-PUR foam may off-gas certain chemicals. 72665
2021-04-06 Class II Nonconforming Material/Component Certain devices were built with motor assemblies that could contain non-conforming plastic material. This could result in 1. Exposure to off-gassing of Volatile Organic Compounds not normally present creating a potential biosafety or toxico 2 units 2024-01-17
2021-04-06 Class II Nonconforming Material/Component Certain devices were built with motor assemblies that could contain non-conforming plastic material. This could result in 1. Exposure to off-gassing of Volatile Organic Compounds not normally present creating a potential biosafety or toxico 22 units 2024-01-17
2008-09-22 Not classified Component design/selection Power Supply failures have occurred on some ventilators. A discrepancy between the power supply strain relief clip and the power cord connector may allow unwanted movement of the cord and the unit’s power supply. A disconnection or interm 2,270 Power Cords 2010-07-06
2007-10-15 Not classified Environmental control Foreign material: Glass fragments may present in the plastic bag material used to ship components. 20950 units 2009-09-01
2007-10-15 Not classified Environmental control Foreign material: Glass fragments may present in the plastic bag material used to ship components. 20950 units 2009-09-01

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.