BiPAP A40
BiPAP A40 EFL, ES with Heated Tube Humidifier (Spain, Portugal)
Who Else Makes It
Concentrated in Guangdong (3), Fujian (1). 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| GaleMed (Xiamen) Co., Ltd. | Xiamen | Fujian | Contract manufacturer | 33 |
| Mehow Innovative (Huizhou) Ltd. | Huizhou | Guangdong | Contract manufacturer | 11 |
| Respironics Medical Products (Shenzhen) Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 8 |
| Shenzhen Mindray BIO-Medical Electronics Co., Ltd. | Shenzhen | Guangdong | Specification developer | 61 |
Record
| Listed by | Respironics Inc., United States |
|---|---|
| FDA product code | MNT |
| Device type | Sv70 Ventilator |
| Device class | Class 2 |
| Regulation | 21 CFR 868.5895 |
| Establishment | Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter |
| Record published | 2016-08-31 |
| Record revised | 2023-02-06 (version 6) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Prescription | Prescription only |
| Latex | Labelled latex-free |
| Label carries | lot or batch number, serial number |
| Storage | Storage environment humidity 15 to 95 % RH; Storage environment temperature -20 to 60 °C; Storage environment temperature -4 to 140 °F |
| Distribution end date | 2022-09-22 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 00 | In distribution | |
| CAX3000T12 | In distribution | |
| 00 | In distribution | |
| GBX3H | In distribution | |
| ITX3000S21 | In distribution | |
| GBX3100H19 | In distribution | |
| CAX3100T12 | In distribution | |
| PPX3010S10 | In distribution | |
| BiPAP A40 Ventilator, INTL, AR | In distribution | |
| DEX3100S13 | In distribution | |
| ESX3000T19 | In distribution | |
| ESX3100H19 | In distribution | |
| ITX3T | In distribution | |
| CAX3100S12 | In distribution | |
| FRX3100T14 | In distribution | |
| NDX3000H19 | In distribution | |
| BLX3T | In distribution | |
| INX3100H19 | In distribution | |
| 00 | In distribution | |
| A40 In-Use Case | In distribution | |
| IAX3000S19 | In distribution | |
| NDX3100H19 | In distribution | |
| ESX3100S19 | In distribution | |
| PPX3110S10 | In distribution | |
| BiPAP A40 EFL, AR | In distribution | |
| INX3100T19 | In distribution | |
| BiPAP A40 Silver Series Ventilator | In distribution | |
| BLX3100S19 | In distribution | |
| DEX3T | In distribution | |
| BiPAP A40 Sapio Belife | In distribution | |
| ESX3T | In distribution | |
| IAX3000H19 | In distribution | |
| BLX3H | In distribution | |
| INX3100S19 | In distribution | |
| INX3HCP | In distribution | |
| ITX3000H21 | In distribution | |
| GBX3T | In distribution | |
| AUX3000S19 | In distribution | |
| GBX3000S19 | In distribution | |
| INX3000H19 | In distribution | |
| DEX3000S13 | In distribution | |
| ITX3H | In distribution | |
| INX3000S19 | In distribution | |
| GBX3000H19 | In distribution | |
| 3000DBM | In distribution | |
| INX3000T19 | In distribution | |
| DEX3H | In distribution | |
| NDX3000T19 | In distribution | |
| GBX3100S19 | In distribution | |
| FRX3100H14 | In distribution | |
| 00 | In distribution | |
| FRX3H | In distribution | |
| ESX3H | In distribution | |
| NDX3000S19 | In distribution | |
| 00 | In distribution | |
| CAX3000S12 | In distribution | |
| BiPAP A40 Ventilator w/H Tube Humid, CA | In distribution | |
| NDX3100T19 | In distribution | |
| 00 | In distribution | |
| IAX3100S19 | In distribution | |
| ITX3000T21 | In distribution | |
| INX3TCP | In distribution | |
| 00 | In distribution | |
| BiPAP A40 Ventilator, CA | In distribution | |
| 00 | In distribution | |
| BLX3000S19 | In distribution | |
| AUX3100S19 | In distribution | |
| ESX3000H19 | In distribution | |
| IAX3100H19 | In distribution | |
| ITX3100S21 | In distribution | |
| ESX3000S19 | In distribution | |
| ESX3100T19 | In distribution | |
| BiPAP A40 EFL, BR | In distribution | |
| IAX3000T19 | In distribution | |
| FRX3T | In distribution | |
| ITX3100T21 | In distribution | |
| GBX3100T19 | In distribution | |
| NDX3H | In distribution | |
| FRX3000H14 | In distribution | |
| 00 | In distribution | |
| EEX3000S19 | In distribution | |
| NDX3T | In distribution | |
| INX3T | In distribution | |
| INX3H | In distribution | |
| NDX3100S19 | In distribution | |
| ITX3100H21 | In distribution | |
| FRX3000T14 | In distribution | |
| GBX3000T19 | In distribution | |
| IAX3100T19 | In distribution | |
| 00 | In distribution | |
| BiPAP A40 Pro, AR | In distribution | |
| FRX3000S14 | In distribution | |
| EEX3100S19 | In distribution | |
| BiPAP A40 Ventilator, FR | In distribution | |
| FRX3100S14 | In distribution | |
| BiPAP A40 Ventilator, CN | In distribution | |
| BiPAP A40 Ventilator Private Label, INTL | Withdrawn | |
| 00 | Withdrawn | |
| BiPAP A40 Ventilator, AU | Withdrawn | |
| BiPAP A40 Ventilator with Humidifier, AU | Withdrawn | |
| BiPAP A40 Ventilator, BR | Withdrawn | |
| BiPAP A40 Silver Series Ventilator, JP | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Philips | Respironics California, Inc. | 29 |
| DreamMapper | Respironics Inc. | 27 |
| Fisher & Paykel Healthcare | Fisher & Paykel Healthcare, Ltd. | 25 |
| BiPAP | Respironics Inc. | 11 |
| EncoreAnywhere | Respironics Inc. | 10 |
| Care Orchestrator | Respironics Inc. | 8 |
| A Series | Respironics Inc. | 7 |
| Nihon Kohden | Nihon Kohden Orangemed, LLC | 6 |
| Remote Alarm | Resmed PTY Ltd. | 5 |
| Stellar | Resmed PTY Ltd. | 5 |
| AF811 | Respironics Inc. | 4 |
| Battery | Respironics Inc. | 4 |
Showing 12 of 53. All products under Sv70 Ventilator
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K121623 | 2012-12-14 |
| K102985 | 2011-04-05 |
| K990574 | 1999-05-24 |
| K982454 | 1998-11-03 |
| K955324 | 1996-12-20 |
| K951264 | 1996-07-29 |
Recalls Naming This Product
2 recalls name this product by its own identifiers, the UDI on its label.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|---|---|
| Respironics Inc. | UDI-DI | 2025-05-09 | Class I | Device Design | This device does not indicate for use in patients with respiratory failure. | 6 units in US 67534 OUS |
| Respironics Inc. | UDI-DI | 2024-03-26 | Class I | Device Design | Potential for devices to experience interruption/loss of therapy during a Ventilator Inoperative alarm. This may lead to hypoventilation, mild to severe hypoxemia, hypercarbia, respiratory failure/insufficiency, or potentially death in the | 6 US, 60,417 OUS |
Recalls
8 of these are Class I. Class I is the FDA’s most serious grade: a reasonable probability of serious injury or death. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2023-08-25 | Class I | Nonconforming Material/Component | Power Management PCBAs may malfunction, causing a power failure leading to ventilator loss of function. | 15 (14 US; 1 OUS) | |
| 2022-02-28 | Class I | Device Design | Ventilator units have an issue impacting an internal electrical circuit within the ventilators, that in some cases could result in the ventilator ceasing to operate. | 12,145 units | |
| 2022-02-28 | Class I | Device Design | Ventilator units have an issue impacting an internal electrical circuit within the ventilators, that in some cases could result in the ventilator ceasing to operate. | 87,138 units | |
| 2022-02-28 | Class I | Device Design | Ventilator units have an issue impacting an internal electrical circuit within the ventilators, that in some cases could result in the ventilator ceasing to operate. | ||
| 2022-01-24 | Class I | Process control | A limited number of ventilators were assembled with expired adhesive. If the adhesive fails, a bracket may become loose and potentially damage the capacitors, which could cause the ventilator to stop providing ventilation to the patient. Th | 294 systems | |
| 2022-01-24 | Class I | Process control | A limited number of ventilators were assembled with expired adhesive. If the adhesive fails, a bracket may become loose and potentially damage the capacitors, which could cause the ventilator to stop providing ventilation to the patient. Th | 16 systems | |
| 2021-06-18 | Class I | Device Design | It has been identified that ventilators equipped with High Flow Therapy (Software Versions 3.00 and 3.10), that includes a designed safety mechanism that limits the amount of pressure that can be delivered to a patient, in situations where | Total of V60/V60 Plus = 23,115 systems | |
| 2021-06-18 | Class I | Device Design | It has been identified that ventilators equipped with High Flow Therapy (Software Versions 3.00 and 3.10), that includes a designed safety mechanism that limits the amount of pressure that can be delivered to a patient, in situations where | Total of V60/V60 Plus = 23,115 systems | |
| 2021-04-06 | Class II | Nonconforming Material/Component | Certain devices were built with motor assemblies that could contain non-conforming plastic material. This could result in 1. Exposure to off-gassing of Volatile Organic Compounds not normally present creating a potential biosafety or toxico | 10 units | 2024-01-17 |
| 2021-04-06 | Class II | Nonconforming Material/Component | Certain devices were built with motor assemblies that could contain non-conforming plastic material. This could result in 1. Exposure to off-gassing of Volatile Organic Compounds not normally present creating a potential biosafety or toxico | 4 units | 2024-01-17 |
| 2021-04-06 | Class II | Nonconforming Material/Component | Certain devices were built with motor assemblies that could contain non-conforming plastic material. This could result in 1. Exposure to off-gassing of Volatile Organic Compounds not normally present creating a potential biosafety or toxico | 1 unit | 2024-01-17 |
| 2021-04-06 | Class II | Nonconforming Material/Component | Certain devices were built with motor assemblies that could contain non-conforming plastic material. This could result in 1. Exposure to off-gassing of Volatile Organic Compounds not normally present creating a potential biosafety or toxico | 4 units | 2024-01-17 |
| 2021-01-06 | Class II | Under Investigation by firm | Due to unqualified “design verification” batteries being shipped to customers. | 94 batteries | |
| 2020-11-02 | Class II | Device Design | Potential issues with ventilator navigation ring interface and liquid ingress: 1) The navigation ring may become inoperative or operate intermittently; 2) The navigation ring may cause ventilator parameter values to change erratically durin | 481 systems (DU1053617)(Amended 07/29/2021 – 44,666 U.S. sys | |
| 2020-11-02 | Class II | Device Design | Potential issues with ventilator navigation ring interface and liquid ingress: 1) The navigation ring may become inoperative or operate intermittently; 2) The navigation ring may cause ventilator parameter values to change erratically durin | 3,453 systems | |
| 2020-11-02 | Class II | Device Design | Potential issues with ventilator navigation ring interface and liquid ingress: 1) The navigation ring may become inoperative or operate intermittently; 2) The navigation ring may cause ventilator parameter values to change erratically durin | 3 systems | |
| 2020-11-02 | Class II | Device Design | Potential issues with ventilator navigation ring interface and liquid ingress: 1) The navigation ring may become inoperative or operate intermittently; 2) The navigation ring may cause ventilator parameter values to change erratically durin | 2,137 systems (Amended on 07/29/2021 – 12 U.S. systems for f | |
| 2020-11-02 | Class II | Device Design | Potential issues with ventilator navigation ring interface and liquid ingress: 1) The navigation ring may become inoperative or operate intermittently; 2) The navigation ring may cause ventilator parameter values to change erratically durin | 216 systems | |
| 2020-11-02 | Class II | Device Design | Potential issues with ventilator navigation ring interface and liquid ingress: 1) The navigation ring may become inoperative or operate intermittently; 2) The navigation ring may cause ventilator parameter values to change erratically durin | 9,856 systems (Amended on 07/29/2021 – 5 U.S. systems for fa | |
| 2020-11-02 | Class II | Device Design | Potential issues with ventilator navigation ring interface and liquid ingress: 1) The navigation ring may become inoperative or operate intermittently; 2) The navigation ring may cause ventilator parameter values to change erratically durin | 834 systems | |
| 2020-11-02 | Class II | Device Design | Potential issues with ventilator navigation ring interface and liquid ingress: 1) The navigation ring may become inoperative or operate intermittently; 2) The navigation ring may cause ventilator parameter values to change erratically durin | 3,841 systems | |
| 2020-11-02 | Class II | Device Design | Potential issues with ventilator navigation ring interface and liquid ingress: 1) The navigation ring may become inoperative or operate intermittently; 2) The navigation ring may cause ventilator parameter values to change erratically durin | 534 systems | |
| 2020-11-02 | Class II | Device Design | Potential issues with ventilator navigation ring interface and liquid ingress: 1) The navigation ring may become inoperative or operate intermittently; 2) The navigation ring may cause ventilator parameter values to change erratically durin | 46,247 systems (Amended on 07/29/2021 – 52,164 U.S. systems | |
| 2020-11-02 | Class II | Device Design | Potential issues with ventilator navigation ring interface and liquid ingress: 1) The navigation ring may become inoperative or operate intermittently; 2) The navigation ring may cause ventilator parameter values to change erratically durin | 3213 systems | |
| 2020-11-02 | Class II | Device Design | Potential issues with ventilator navigation ring interface and liquid ingress: 1) The navigation ring may become inoperative or operate intermittently; 2) The navigation ring may cause ventilator parameter values to change erratically durin | 682 systems (Amended on 07/29/2021 – 15,185 U.S. systems for | |
| 2020-11-02 | Class II | Device Design | Potential issues with ventilator navigation ring interface and liquid ingress: 1) The navigation ring may become inoperative or operate intermittently; 2) The navigation ring may cause ventilator parameter values to change erratically durin | 3,752 systems | |
| 2020-11-02 | Class II | Device Design | Potential issues with ventilator navigation ring interface and liquid ingress: 1) The navigation ring may become inoperative or operate intermittently; 2) The navigation ring may cause ventilator parameter values to change erratically durin | 934 systems | |
| 2020-11-02 | Class II | Device Design | Potential issues with ventilator navigation ring interface and liquid ingress: 1) The navigation ring may become inoperative or operate intermittently; 2) The navigation ring may cause ventilator parameter values to change erratically durin | 10,291 systems | |
| 2020-11-02 | Class II | Device Design | Potential issues with ventilator navigation ring interface and liquid ingress: 1) The navigation ring may become inoperative or operate intermittently; 2) The navigation ring may cause ventilator parameter values to change erratically durin | 330 systems (Amended on 07/29/2021 – 44,841 U.S. systems for | |
| 2020-10-30 | Class II | Device Design | Ventilator may experience potential issues with the backup battery failures: 1) if the battery is allowed to over discharge, or 2) if the ventilator is stored for an extended period of time without being plugged into AC power. | 216 systems | 2024-09-19 |
| 2020-10-30 | Class II | Device Design | Ventilator may experience potential issues with the backup battery failures: 1) if the battery is allowed to over discharge, or 2) if the ventilator is stored for an extended period of time without being plugged into AC power. | 702 system | 2024-09-19 |
| 2020-10-30 | Class II | Device Design | Ventilator may experience potential issues with the backup battery failures: 1) if the battery is allowed to over discharge, or 2) if the ventilator is stored for an extended period of time without being plugged into AC power. | 292 systems | 2024-09-19 |
| 2020-10-30 | Class II | Device Design | Ventilator may experience potential issues with the backup battery failures: 1) if the battery is allowed to over discharge, or 2) if the ventilator is stored for an extended period of time without being plugged into AC power. | 3,752 systems | 2024-09-19 |
| 2020-10-30 | Class II | Device Design | Ventilator may experience potential issues with the backup battery failures: 1) if the battery is allowed to over discharge, or 2) if the ventilator is stored for an extended period of time without being plugged into AC power. | 46,313 systems | 2024-09-19 |
| 2020-10-30 | Class II | Device Design | Ventilator may experience potential issues with the backup battery failures: 1) if the battery is allowed to over discharge, or 2) if the ventilator is stored for an extended period of time without being plugged into AC power. | 2,144 Systems | 2024-09-19 |
| 2020-10-30 | Class II | Device Design | Ventilator may experience potential issues with the backup battery failures: 1) if the battery is allowed to over discharge, or 2) if the ventilator is stored for an extended period of time without being plugged into AC power. | 3,453 systems | 2024-09-19 |
| 2020-10-30 | Class II | Device Design | Ventilator may experience potential issues with the backup battery failures: 1) if the battery is allowed to over discharge, or 2) if the ventilator is stored for an extended period of time without being plugged into AC power. | 3,213 systems | 2024-09-19 |
| 2020-10-30 | Class II | Device Design | Ventilator may experience potential issues with the backup battery failures: 1) if the battery is allowed to over discharge, or 2) if the ventilator is stored for an extended period of time without being plugged into AC power. | 934 systems | 2024-09-19 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.