INOmax

TEE, O2 Tubing Sample, NO Bushing BCG, CE 2797

Registry build 21.09.26
1manufacturer
18catalogue numbers in this listing
4510(k) clearances naming this product code
6recalls on this code

Who Else Makes It

Registered in Guangdong. One is registered as a contract manufacturer, able to build to a specification.

Chinese manufacturers registered for FDA product code MRN
Manufacturer City Province Registered as Device types
AOK Tooling Limited Shen Zhen Guangdong Contract manufacturer 6

Record

Regulatory record for INOmax
Listed by Mallinckrodt Manufacturing LLC, United States
FDA product code MRN
Device type Apparatus, Nitric Oxide Delivery
Device class Class 2
Regulation 21 CFR 868.5165
Establishment Contract manufacturer, Remanufacturer, Manufacturer
510(k) K222930
Record published 2023-05-10

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date, manufacturing date, serial number
Storage Storage environment temperature -20 to 60 °C; Storage environment humidity 15 to 95 % RH; Storage environment atmospheric pressure 57 to 110 KiloPascal
Packaging Pack of 5

Catalogue Numbers

Catalogue numbers for INOmax
Catalogue number Size Status
90844 In distribution
91270 In distribution
10107 In distribution
50239 In distribution
50312 In distribution
91359 In distribution
90845 In distribution
50371 In distribution
10022 In distribution
10090 In distribution
91351 In distribution
10095 In distribution
50280 In distribution
90855 In distribution
10006 In distribution
50372 In distribution
50370 In distribution
10020 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Genosyl® Vero Biotech Inc. 17
NOxBOXi Noxkit Vero Biotech Inc. 7
AeroNOx 2.0 Nitric Oxide Delivery Device International Biomedical, Ltd. 1
AeroNOx Nitric Oxide Delivery Device International Biomedical, Ltd. 1
Ulspira TS Airgas Therapeutics LLC 1

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K242578 2025-01-03
K222930 2023-12-06
K211153 2023-04-20
K200389 2020-06-17

Recalls Naming This Product

4 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of INOmax
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Mallinckrodt Manufacturing LLC 510(k) number 2018-07-09 Class II Process control INOmeters affixed to the INOflo cylinders in Lot 17FP-0570 were programmed with an incorrect expiration date (11/2017). For Lot 17FP-0570, the label affixed to each INOflo cylinder has the correct expiration date noted (11/2020). 108 units 2020-11-30
Mallinckrodt Manufacturing LLC 510(k) number 2016-11-21 Class II Equipment maintenance Mallinckrodt discovered that some devices may have been manufactured with an out-of-tolerance manometer which can result in in an inaccurate proportional valve calibration table in an affected device. 45 2017-12-20
Mallinckrodt Manufacturing LLC 510(k) number 2014-10-17 Class II Process change control An issue has been identified in the INOmax DSIR system that could result in monitored Nitric Oxide (NO) concentration reporting lower than expected. This issue only pertains to those devices manufactured using a specific version of the Mon 9 2015-04-16
Mallinckrodt Manufacturing LLC 510(k) number 2014-03-27 Class II Software Design Change An anomaly impacts the monitoring system of INOmax DSIR Plus (software 3.0.0). When the integrated pneumatic backup switch is activated with low or no gas flow through the injector module, an intended NO cell failure alarm will occur. In 22 2014-11-21

Recalls

1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2015-01-14 Class II Process change control Potential delivery failure alarm condition. INOmax DSIR with software version 2.0.4 and a certain variant of the monitor display may trigger a delivery failure alarm when the display brightness is set to its lowest level. If this conditio 45 units 2015-04-15
2010-11-30 Not classified Nonconforming Material/Component Through the review and monitoring of its complaint data, Ikaria identified a product anomaly with the INOmax DS Model 1003. Ikaria concluded the anomaly risk to the patient safety was low and non reportable (4/23/10). During a subsequent L 2446 2012-05-29

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.