Swan-Ganz HI-Shore True Size

HI Torque SG Flow Directed Monit Cath W/ Bonded Balloon

Registry build 21.09.26
1manufacturer
1catalogue number
4510(k) clearances naming this product code
7recalls on this code

Who Else Makes It

Registered in Guangdong. One is registered as a contract manufacturer, able to build to a specification.

Chinese manufacturers registered for FDA product code DQE
Manufacturer City Province Registered as Device types
Amphenol Medical Technologies (Dongguan) Co., Ltd. Dongguan Guangdong Contract manufacturer 77

Record

Regulatory record for Swan-Ganz HI-Shore True Size
Listed by Edwards Lifesciences Technology Sarl, United States
FDA product code DQE
Device type Catheter, Oximeter, Fiber-Optic
Device class Class 2
Regulation 21 CFR 870.1230
Establishment Contract manufacturer, Specification developer, Manufacturer
510(k) K160084
Record published 2016-09-03
Record revised 2023-12-04 (version 6)

Specifications

Specifications
MRI safety MR Safe
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Supplied as a kit Yes
Latex Contains natural rubber latex
Label carries lot or batch number, expiry date, manufacturing date
Storage Special storage condition: STORE IN A COOL, DRY PLACE.

Catalogue Numbers

Catalogue numbers for Swan-Ganz HI-Shore True Size
Catalogue number Size Status
T123F6 EXTERIOR DIAMETER: 6F (2.0MM), USABLE LENGTH: 110 CM, RECOMMENDED GUIDEWIRE SIZE: 0.030 IN (0.76 MM), MINIMUM INTRODUCER SIZE: 6F (2.0MM) In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
ICU Medical ICU Medical, Inc 65
Vital Signs™ AirLife Finland Oy 12
Swan-Ganz Edwards Lifesciences Technology Sarl 7
Edwards Oximetry Central Venous Catheter Edwards Lifesciences Technology Sarl 6
Vital Signs Carefusion Finland 320 Oy 6
HemoSphere Edwards Lifesciences Technology Sarl 5
Swan-Ganz True Size Edwards Lifesciences Technology Sarl 3
HemoSphere Alta Edwards Lifesciences Technology Sarl 3
Flotrac Edwards Lifesciences Technology Sarl 3
Vigileo Edwards Lifesciences Technology Sarl 2
ForeSight IQ Edwards Lifesciences Technology Sarl 1
Pediasat Edwards Lifesciences Technology Sarl 1

Showing 12 of 18. All products under Catheter, Oximeter, Fiber-Optic

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K160645 2016-06-16
K110167 2011-02-18
K060093 2006-04-28
K053609 2006-02-28

Recalls Naming This Product

4 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of Swan-Ganz HI-Shore True Size
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Edwards Lifesciences Technology Sarl 510(k) number 2018-12-21 Class I Nonconforming Material/Component These Swan Ganz catheters have incorrect lumen assembly, which causes reversal of the lumens. If the lumens are reversed the clinician may note reverse PA and CVP pressure values and waveforms. 277 units 2023-11-02
Edwards Lifesciences Technology Sarl 510(k) number 2018-12-21 Class I Nonconforming Material/Component These Swan Ganz catheters have incorrect lumen assembly, which causes reversal of the lumens. If the lumens are reversed the clinician may note reverse PA and CVP pressure values and waveforms. 875 units 2023-11-02
Edwards Lifesciences Technology Sarl 510(k) number 2018-12-21 Class I Nonconforming Material/Component These Swan Ganz catheters have incorrect lumen assembly, which causes reversal of the lumens. If the lumens are reversed the clinician may note reverse PA and CVP pressure values and waveforms. 9 units 2023-11-02
Edwards Lifesciences Technology Sarl 510(k) number 2018-12-21 Class I Nonconforming Material/Component These Swan Ganz catheters have incorrect lumen assembly, which causes reversal of the lumens. If the lumens are reversed the clinician may note reverse PA and CVP pressure values and waveforms. 459 units 2023-11-02

Recalls

7 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2021-07-09 Class II Process control There is a potential for internal leaks within catheters. 70 UNITS 2024-01-29
2021-07-09 Class II Process control There is a potential for internal leaks within catheters. 218 UNITS 2024-01-29
2021-07-09 Class II Process control There is a potential for internal leaks within catheters. 152 units 2024-01-29
2021-07-09 Class II Process control There is a potential for internal leaks within catheters. 178 units 2024-01-29
2021-07-09 Class II Process control There is a potential for internal leaks within catheters. 50 units 2024-01-29
2021-07-09 Class II Process control There is a potential for internal leaks within catheters. 200 UNITS 2024-01-29
2020-03-27 Class II Under Investigation by firm Sterile catheter kit packaging compromised. 597 units 2021-04-27

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer