Ablamap® System
The Ablamap® System is an electrophysiology mapping system for assisting in the diagnosis of complex cardiac arrhythmias. The system consists of several hardware elements including an…
The Ablamap® System is an electrophysiology mapping system for assisting in the diagnosis of complex cardiac arrhythmias. The system consists of several hardware elements including an amplifier, cart, monitor, and workstation that contains proprietary mapping software. Signals are transmitted from a 64-electrode mapping “basket” catheter, through the amplifier, to the workstation, processed by the mapping software, and the results are displayed on the monitor.
Who Else Makes It
Concentrated in Guangdong (7), Shanghai (2), Jiangsu (1). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Amphenol Medical Technologies (Dongguan) Co., Ltd. | Dongguan | Guangdong | Contract manufacturer | 77 |
| Jabil Circuit (Shanghai) Ltd. | Shanghai | Shanghai | Contract manufacturer | 31 |
| Amphenol Alden Products Company | Shenzhen | Guangdong | Contract manufacturer | 24 |
| Dongguan Ergotron Precision Technology Co., Ltd. | Dongguan | Guangdong | Contract manufacturer | 2 |
| Shenzhen Mindray BIO-Medical Electronics Co., Ltd. | Shenzhen | Guangdong | Specification developer | 61 |
| GE Medical Systems (China) Co., Ltd. | Wuxi | Jiangsu | Contract manufacturer | 57 |
| Edan Instruments, Inc. | Shenzhen | Guangdong | Contract manufacturer | 56 |
| Shenzhen BelterHealthMeasurementAndAnalysisTechnologyCo.,Ltd | Shenzhen | Guangdong | Manufacturer | 7 |
| Philips (China) Investment Co., Ltd. Philips Healthcare – Shanghai CDC | Shanghai | Shanghai | Specification developer | 6 |
| Shenzhen Carewell Electronics Co., Ltd. | Shenzhen | Guangdong | Manufacturer | 2 |
Record
| Listed by | Ablacon, Inc., United States |
|---|---|
| FDA product code | DQK |
| Device type | Computer, Diagnostic, Programmable |
| Device class | Class 2 |
| Regulation | 21 CFR 870.1425 |
| Record published | 2023-12-07 |
| Record revised | 2025-10-16 (version 4) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Prescription | Prescription only |
| Label carries | manufacturing date, serial number |
| Storage | Storage environment humidity 10 to 80 % RH; Storage environment temperature 0 to 50 °C |
| UDI direct marking | Exempt |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| AB-0007 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| EnSite™ | St. Jude Medical | 177 |
| Computer, Diagnostic, Programmable | St. Jude Medical | 57 |
| MediGuide™ | St. Jude Medical | 41 |
| AcQMap | Acutus Medical, Inc. | 38 |
| WorkMate Claris™ | St. Jude Medical | 35 |
| iLab Ultrasound Imaging System | Boston Scientific Corporation | 32 |
| Rhythmia™ Mapping System | Boston Scientific Corporation | 31 |
| Sentinel | Spacelabs Healthcare (Washington), Inc | 28 |
| Rhythmia HDx™ | Boston Scientific Corporation | 26 |
| EnSite Precision™ | St. Jude Medical | 23 |
| PathfinderSL | Spacelabs Healthcare (Washington), Inc | 22 |
| Labsystem™ PRO | Boston Scientific Corporation | 19 |
Showing 12 of 228. All products under Computer, Diagnostic, Programmable
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K230008 | 2023-06-08 |
| K203084 | 2021-08-31 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.