Carescape Central Station
MAI800 Medical Device
Who Else Makes It
Concentrated in Guangdong (7), Shanghai (2), Jiangsu (1). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Amphenol Medical Technologies (Dongguan) Co., Ltd. | Dongguan | Guangdong | Contract manufacturer | 77 |
| Jabil Circuit (Shanghai) Ltd. | Shanghai | Shanghai | Contract manufacturer | 31 |
| Amphenol Alden Products Company | Shenzhen | Guangdong | Contract manufacturer | 24 |
| Dongguan Ergotron Precision Technology Co., Ltd. | Dongguan | Guangdong | Contract manufacturer | 2 |
| Shenzhen Mindray BIO-Medical Electronics Co., Ltd. | Shenzhen | Guangdong | Specification developer | 61 |
| GE Medical Systems (China) Co., Ltd. | Wuxi | Jiangsu | Contract manufacturer | 57 |
| Edan Instruments, Inc. | Shenzhen | Guangdong | Contract manufacturer | 56 |
| Shenzhen BelterHealthMeasurementAndAnalysisTechnologyCo.,Ltd | Shenzhen | Guangdong | Manufacturer | 7 |
| Philips (China) Investment Co., Ltd. Philips Healthcare – Shanghai CDC | Shanghai | Shanghai | Specification developer | 6 |
| Shenzhen Carewell Electronics Co., Ltd. | Shenzhen | Guangdong | Manufacturer | 2 |
Record
| Listed by | GE Medical Systems Information Technologies, Inc., United States |
|---|---|
| FDA product code | DQK |
| Device type | Computer, Diagnostic, Programmable |
| Device class | Class 2 |
| Regulation | 21 CFR 870.1425 |
| Establishment | Specification developer, Repacker / relabeller, Manufacturer |
| 510(k) | K162012 |
| Record published | 2026-02-11 |
Specifications
| MRI safety | MR Safe |
|---|---|
| Prescription | Prescription only |
| Label carries | manufacturing date, serial number |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| MAI800 | In distribution | |
| MAI800 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| EnSite™ | St. Jude Medical | 177 |
| Computer, Diagnostic, Programmable | St. Jude Medical | 57 |
| MediGuide™ | St. Jude Medical | 41 |
| AcQMap | Acutus Medical, Inc. | 38 |
| WorkMate Claris™ | St. Jude Medical | 35 |
| iLab Ultrasound Imaging System | Boston Scientific Corporation | 32 |
| Rhythmia™ Mapping System | Boston Scientific Corporation | 31 |
| Sentinel | Spacelabs Healthcare (Washington), Inc | 28 |
| Rhythmia HDx™ | Boston Scientific Corporation | 26 |
| EnSite Precision™ | St. Jude Medical | 23 |
| PathfinderSL | Spacelabs Healthcare (Washington), Inc | 22 |
| Labsystem™ PRO | Boston Scientific Corporation | 19 |
Showing 12 of 228. All products under Computer, Diagnostic, Programmable
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K243540 | 2024-12-12 |
| K231870 | 2023-12-13 |
| K202189 | 2020-12-08 |
| K152993 | 2016-01-12 |
| K132437 | 2013-12-04 |
| K130626 | 2013-05-01 |
| K130155 | 2013-03-01 |
| K110132 | 2011-05-25 |
| K103678 | 2011-02-16 |
| K093141 | 2009-12-29 |
| K083639 | 2009-02-17 |
| K072502 | 2007-11-19 |
| K051026 | 2005-07-19 |
| K050093 | 2005-05-13 |
| K050614 | 2005-04-05 |
| K032513 | 2003-10-30 |
| K032577 | 2003-10-10 |
| K031561 | 2003-08-01 |
Recalls Naming This Product
6 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| GE Medical Systems Information Technologies, Inc. | 510(k) number | 2026-07-30 | Not classified | Under Investigation by firm | Device may not resume patient monitoring for at least 3 minutes following system restart. Issue can lead to potential delay in recognition of clinically significant events. | 29,570 (23,632 US; 5,938 OUS) | |
| Wipro GE Healthcare Private Ltd. | 510(k) number | 2025-09-05 | Class II | Software design | Carescape Central Station (CSCS), software version V3.0.5, can cause the system to enter a continuous reboot cycle. If this occurs, a loss of central monitoring of connected patients could result. This issue occurs only when the number of c | 173 units | |
| Wipro GE Healthcare Private Ltd. | 510(k) number | 2025-09-05 | Class II | Software design | Carescape Central Station (CSCS), software version V3.0.5, can cause the system to enter a continuous reboot cycle. If this occurs, a loss of central monitoring of connected patients could result. This issue occurs only when the number of c | 2365 units | |
| GE Medical Systems, LLC | 510(k) number | 2022-05-10 | Class II | Process control | The CARESAPE Central Station (CSCS) V2 can shut down due to a potential power supply component failure. This can lead to loss of patient monitoring at the central station. | 30,993 Central Stations and 2,180 FRUs and displays | |
| GE Medical Systems, LLC | 510(k) number | 2022-01-28 | Class II | Software design | If the CARESCAPE Central Station v2.0 is used with an unapproved keyboard, the audio can be muted resulting in loss of audible alarms. | 10,445 units | |
| GE Medical Systems Information Technologies, Inc. | 510(k) number | 2018-01-11 | Class II | Software in the Use Environment | CARESCAPE Central Station (CSCS) software version 2.0.2 units may experience unexpected NO COMM (No Communication) and network communication issues after boot-up or system restart. | 1803 units | 2021-07-07 |
Recalls
3 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|
| 2026-04-24 | Class II | Process control | Electrical sparking may occur at the printer head. If the Electrostatic Discharge (ESD) printer brush becomes dislodged, electrical sparking at the printer head can result in charring or discoloration of thermal printer paper. Ignition of t | 1835 |
| 2024-04-22 | Class II | Process control | Capacitors in certain Prucka 3 Amplifiers used with CardioLab / ComboLab systems could fail resulting in transient oscillations on the display and inability to view surface and intracardiac ECG waveforms. | 145 units |
| 2023-08-08 | Class II | Component design/selection | A diode on the power supply of the Prucka 3 Amplifier used with CardioLab/ComboLab systems could reach elevated temperatures and fail, then power off and become inoperable. | 81 amplifiers |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.