Hemosphere
Mindray OEM Pressure Smart Cable
Who Else Makes It
Concentrated in Guangdong (7), Shanghai (2), Jiangsu (1). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Amphenol Medical Technologies (Dongguan) Co., Ltd. | Dongguan | Guangdong | Contract manufacturer | 77 |
| Jabil Circuit (Shanghai) Ltd. | Shanghai | Shanghai | Contract manufacturer | 31 |
| Amphenol Alden Products Company | Shenzhen | Guangdong | Contract manufacturer | 24 |
| Dongguan Ergotron Precision Technology Co., Ltd. | Dongguan | Guangdong | Contract manufacturer | 2 |
| Shenzhen Mindray BIO-Medical Electronics Co., Ltd. | Shenzhen | Guangdong | Specification developer | 61 |
| GE Medical Systems (China) Co., Ltd. | Wuxi | Jiangsu | Contract manufacturer | 57 |
| Edan Instruments, Inc. | Shenzhen | Guangdong | Contract manufacturer | 56 |
| Shenzhen BelterHealthMeasurementAndAnalysisTechnologyCo.,Ltd | Shenzhen | Guangdong | Manufacturer | 7 |
| Philips (China) Investment Co., Ltd. Philips Healthcare – Shanghai CDC | Shanghai | Shanghai | Specification developer | 6 |
| Shenzhen Carewell Electronics Co., Ltd. | Shenzhen | Guangdong | Manufacturer | 2 |
Record
| Listed by | Edwards Lifesciences Technology Sarl, United States |
|---|---|
| FDA product code | DQK |
| Device type | Computer, Diagnostic, Programmable |
| Device class | Class 2 |
| Regulation | 21 CFR 870.1425 |
| Establishment | Contract manufacturer, Specification developer, Manufacturer |
| 510(k) | K191089 |
| Record published | 2025-07-15 |
| Record revised | 2025-09-11 (version 5) |
Specifications
| MRI safety | MR Unsafe |
|---|---|
| Prescription | Prescription only |
| Label carries | manufacturing date, serial number |
| Storage | Special storage condition: Store in a cool, dry place. |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| PSCOEM100MR | In distribution | |
| HEMCSM10 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| EnSite™ | St. Jude Medical | 177 |
| Computer, Diagnostic, Programmable | St. Jude Medical | 57 |
| MediGuide™ | St. Jude Medical | 41 |
| AcQMap | Acutus Medical, Inc. | 38 |
| WorkMate Claris™ | St. Jude Medical | 35 |
| iLab Ultrasound Imaging System | Boston Scientific Corporation | 32 |
| Rhythmia™ Mapping System | Boston Scientific Corporation | 31 |
| Sentinel | Spacelabs Healthcare (Washington), Inc | 28 |
| Rhythmia HDx™ | Boston Scientific Corporation | 26 |
| EnSite Precision™ | St. Jude Medical | 23 |
| PathfinderSL | Spacelabs Healthcare (Washington), Inc | 22 |
| Labsystem™ PRO | Boston Scientific Corporation | 19 |
Showing 12 of 228. All products under Computer, Diagnostic, Programmable
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K253186 | 2026-02-24 |
| K252533 | 2025-12-18 |
| K253034 | 2025-10-21 |
| K243781 | 2025-07-23 |
| K232294 | 2023-10-31 |
| K230579 | 2023-08-18 |
| K231035 | 2023-07-12 |
| K223865 | 2023-06-09 |
| K221704 | 2022-11-22 |
| K213682 | 2022-06-22 |
| K203687 | 2021-05-28 |
| K190205 | 2019-08-29 |
| K191089 | 2019-06-13 |
| K180881 | 2018-11-16 |
| K163381 | 2017-04-14 |
Recalls
2 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2019-10-07 | Class II | Process control | Intermittent communication due to inconsistent crimping of connectors onto cables. | 35 | 2021-04-27 |
| 2017-10-02 | Class II | Device Design | Pre-procedural issues related to software defects | 198 devices | 2020-12-14 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.