McKesson Cardiology ECG Management
2 catalogue numbers from 14.0, listed by Change Healthcare Canada Company, Canada, under Computer, Diagnostic, Programmable. 10 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Guangdong (7), Shanghai (2), Jiangsu (1). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Amphenol Medical Technologies (Dongguan) Co., Ltd. | Dongguan | Guangdong | Contract manufacturer | 77 |
| Jabil Circuit (Shanghai) Ltd. | Shanghai | Shanghai | Contract manufacturer | 31 |
| Amphenol Alden Products Company | Shenzhen | Guangdong | Contract manufacturer | 24 |
| Dongguan Ergotron Precision Technology Co., Ltd. | Dongguan | Guangdong | Contract manufacturer | 2 |
| Shenzhen Mindray BIO-Medical Electronics Co., Ltd. | Shenzhen | Guangdong | Specification developer | 61 |
| GE Medical Systems (China) Co., Ltd. | Wuxi | Jiangsu | Contract manufacturer | 57 |
| Edan Instruments, Inc. | Shenzhen | Guangdong | Contract manufacturer | 56 |
| Shenzhen BelterHealthMeasurementAndAnalysisTechnologyCo.,Ltd | Shenzhen | Guangdong | Manufacturer | 7 |
| Philips (China) Investment Co., Ltd. Philips Healthcare – Shanghai CDC | Shanghai | Shanghai | Specification developer | 6 |
| Shenzhen Carewell Electronics Co., Ltd. | Shenzhen | Guangdong | Manufacturer | 2 |
Record
| Listed by | Change Healthcare Canada Company, Canada |
|---|---|
| FDA product code | DQK |
| Device type | Computer, Diagnostic, Programmable |
| Device class | Class 2 |
| Regulation | 21 CFR 870.1425 |
| Establishment | Repacker / relabeller, Manufacturer, Exporter |
| 510(k) | K113515 |
| Record published | 2017-03-09 |
| Record revised | 2023-07-20 (version 4) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Label carries | lot or batch number |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 14.0 | In distribution | |
| 13.2.1 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| EnSite™ | St. Jude Medical | 177 |
| Computer, Diagnostic, Programmable | St. Jude Medical | 57 |
| MediGuide™ | St. Jude Medical | 41 |
| AcQMap | Acutus Medical, Inc. | 38 |
| WorkMate Claris™ | St. Jude Medical | 35 |
| iLab Ultrasound Imaging System | Boston Scientific Corporation | 32 |
| Rhythmia™ Mapping System | Boston Scientific Corporation | 31 |
| Sentinel | Spacelabs Healthcare (Washington), Inc | 28 |
| Rhythmia HDx™ | Boston Scientific Corporation | 26 |
| EnSite Precision™ | St. Jude Medical | 23 |
| PathfinderSL | Spacelabs Healthcare (Washington), Inc | 22 |
| Labsystem™ PRO | Boston Scientific Corporation | 19 |
Showing 12 of 228. All products under Computer, Diagnostic, Programmable
Recalls Naming This Product
2 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Change Healthcare Canada Company | 510(k) number | 2020-02-10 | Class II | Device Design | Inaccurate estimation of the heart rate may occur in instances where the user is estimating heart rate counting grid squares using the Sequential ECG format | 51 units | |
| Change Healthcare Israel Ltd. | 510(k) number | 2014-12-19 | Class II | Software design | An ECG procedure time stamp is incorrect, due to a software error in the McKesson Cardiology ECG Management with software versions 13.1 and 13.1.1. | 9 | 2016-02-25 |
Recalls
2 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|
| 2024-08-21 | Class II | Use error | A potential issue has been identified in Change Healthcare Cardiology Hemo where incorrect data entry can lead to inaccurate hemodynamic calculations, potentially resulting in misdiagnosis and inappropriate treatment. This issue occurs when | 35 systems |
| 2024-08-21 | Class II | Use error | A potential issue has been identified in Change Healthcare Cardiology Hemo where incorrect data entry can lead to inaccurate hemodynamic calculations, potentially resulting in misdiagnosis and inappropriate treatment. This issue occurs when | 3 systems |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.