Merge Hemo

7 catalogue numbers from RCSV2, listed by Merge Healthcare Solutions Inc., under Computer, Diagnostic, Programmable. 10 manufacturers in China are registered for this product code.

Registry build 21.09.26
10manufacturers in China registered for this device type
7catalogue numbers in this listing

Who Else Makes It

Concentrated in Guangdong (7), Shanghai (2), Jiangsu (1). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code DQK
Manufacturer City Province Registered as Device types
Amphenol Medical Technologies (Dongguan) Co., Ltd. Dongguan Guangdong Contract manufacturer 77
Jabil Circuit (Shanghai) Ltd. Shanghai Shanghai Contract manufacturer 31
Amphenol Alden Products Company Shenzhen Guangdong Contract manufacturer 24
Dongguan Ergotron Precision Technology Co., Ltd. Dongguan Guangdong Contract manufacturer 2
Shenzhen Mindray BIO-Medical Electronics Co., Ltd. Shenzhen Guangdong Specification developer 61
GE Medical Systems (China) Co., Ltd. Wuxi Jiangsu Contract manufacturer 57
Edan Instruments, Inc. Shenzhen Guangdong Contract manufacturer 56
Shenzhen BelterHealthMeasurementAndAnalysisTechnologyCo.,Ltd Shenzhen Guangdong Manufacturer 7
Philips (China) Investment Co., Ltd. Philips Healthcare – Shanghai CDC Shanghai Shanghai Specification developer 6
Shenzhen Carewell Electronics Co., Ltd. Shenzhen Guangdong Manufacturer 2

Record

Regulatory record for Merge Hemo
Listed by Merge Healthcare Solutions Inc.
FDA product code DQK
Device type Computer, Diagnostic, Programmable
Device class Class 2
Regulation 21 CFR 870.1425
510(k) K152864
Record published 2020-04-23
Record revised 2026-03-12 (version 5)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only
Label carries lot or batch number, manufacturing date, serial number
Distribution end date 2026-01-31

Catalogue Numbers

Catalogue numbers for Merge Hemo
Catalogue number Size Status
RCSV2 In distribution
10.4 In distribution
10.3 Withdrawn
10.0.4 Withdrawn
10.1 Withdrawn
9.4 Withdrawn
10.2 Withdrawn

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
EnSite™ St. Jude Medical 177
Computer, Diagnostic, Programmable St. Jude Medical 57
MediGuide™ St. Jude Medical 41
AcQMap Acutus Medical, Inc. 38
WorkMate Claris™ St. Jude Medical 35
iLab Ultrasound Imaging System Boston Scientific Corporation 32
Rhythmia™ Mapping System Boston Scientific Corporation 31
Sentinel Spacelabs Healthcare (Washington), Inc 28
Rhythmia HDx™ Boston Scientific Corporation 26
EnSite Precision™ St. Jude Medical 23
PathfinderSL Spacelabs Healthcare (Washington), Inc 22
Labsystem™ PRO Boston Scientific Corporation 19

Showing 12 of 228. All products under Computer, Diagnostic, Programmable

Recalls Naming This Product

14 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of Merge Hemo
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Merge Healthcare Incorporated 510(k) number 2025-08-11 Class II Process control Merge Healthcare has been informed by Schiller AG (Baar, Switzerland) of an issue with the Schiller ARGUS PB-3000 Patient Data Module (PDM) where certain units trigger an error message on the Merge Hemo Client (Pressure Sensor Defective) du 84
Merge Healthcare Incorporated 510(k) number 2021-07-23 Class II Under Investigation by firm The firm identified a safety issue affecting the software associated with Merge Hemo versions 9.x and 10.x, used in combination with an HL7 lab interface. 326 units 2023-08-29
Merge Healthcare Incorporated 510(k) number 2017-04-06 Class II Component design/selection Merge is conducting a hardware recall (replacement) of Fellows “Mighty 8” Power Strip and TrippLite Power Strip due to overheat of input resistor causing the power strip to smoke. 1,150 power strips 2019-07-10
Merge Healthcare Incorporated 510(k) number 2016-04-04 Class II Software design In some instances, the system will lock tabs within a study, even when a second user does not have the study open on a different workstation. 361 sites potentially have the affected versions 2019-08-05
Merge Healthcare Incorporated 510(k) number 2016-04-04 Class II Software design Use of the software may show an incorrect value to the user when viewing the Fractional Flow Reserve (FFR) results during recording. 24 sites potentially have the affected versions 2019-02-21
Merge Healthcare Incorporated 510(k) number 2016-03-28 Class II Software design There is a potential connection issue when powering up the Merge Hemo Record Station and the Hemo Monitor does not communicate with the Client PC. 242 sites potentially have the affected versions 2019-06-28
Merge Healthcare Incorporated 510(k) number 2016-03-10 Class II Software design If the PDM is utilized to output a pressure for computing fractional flow reserve (FFR), the analog output may not reflect the true representation of the selected pressure waveform being provided by the PDM to the Link Assembly which provid 555 PDM’s 2020-03-06
Merge Healthcare Incorporated 510(k) number 2015-10-26 Class II Process control The firm, Merge Healthcare, sent out Merge HEMO V10.0 & Merge CARDIO V10.1 software to 3 customers before the product was completely validated in house. 2 2016-07-22
Merge Healthcare Incorporated 510(k) number 2015-05-31 Class II Nonconforming Material/Component Non-invasive blood pressure pumps (NIBP) voltage is not sufficient and causes the NIBP pumps to fail prior to reaching adequate initial pressure. 341 sites potentially have the affected product versions 2020-03-13
Merge Healthcare Incorporated 510(k) number 2015-03-30 Class II Unknown/Undetermined by firm The units may display the alarm “sampling line clogged” after the flow zeroing procedure that is conducted automatically 1 hour after start up. This could result in the potential of a small bias added to the CO2 measurement and affect the 23 sensors (PhaseIn Units) 2017-05-05
Merge Healthcare Incorporated 510(k) number 2015-01-21 Class II Software design A system freeze-up of the Merge Hemo system, that included the PHASEIN End Tidal CO2 unit, resulted in the user needing to move the patient to another cath lab. 451 2015-12-09
Merge Healthcare Incorporated 510(k) number 2014-09-29 Class II Software design It has been reported that during use, the SpO2 value displayed on the Hemo Monitor may not update to reflect changes in the patient’s oxygen value. It is also possible that if using the pulse rate of the SpO2 finger clip to calculate the p 52 2016-08-25
Merge Healthcare Incorporated 510(k) number 2014-04-30 Class II Software design The application may crash during the cath lab procedure. 192 sites potentially have the affected software 2019-12-23
Merge Healthcare Incorporated 510(k) number 2012-07-02 Class II Software design The International Normalized Ratio (INR) value displayed in the study report does not match the value that is imported on the pre-procedure labs screen from HL7 37 2017-06-26

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer