BCI

6 catalogue numbers from 3137, listed by ICU Medical, Inc, United States, under Catheter, Intravascular, Diagnostic. 11 manufacturers in China are registered for this product code.

Registry build 21.09.26
11manufacturers in China registered for this device type
6catalogue numbers in this listing
2510(k) clearances naming this product code
10recalls on this code

Who Else Makes It

Concentrated in Jiangsu (5), Guangdong (3), Zhejiang (2). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code DQO
Manufacturer City Province Registered as Device types
GE Medical Systems (China) Co., Ltd. Wuxi Jiangsu Contract manufacturer 57
Amsino Medical (Kunshan) Co., Ltd. Kunshan Jiangsu Contract manufacturer 53
Conod Medical Shuyang Co., Ltd. Shuyang Jiangsu Contract manufacturer 22
Bioxin Medical Co., Ltd. Weihai Shandong Contract manufacturer 8
GRI Medical & Electronic Technology Co., Ltd. Jiaxing Zhejiang Contract manufacturer 71
Goals Sterilization Co., Ltd. Jiaxing Zhejiang Contract manufacturer 26
Wuxi Goals Medical Technology Co., Ltd. Yixing Jiangsu Contract manufacturer 24
Sunny Medical Device (Shenzhen) Co., Ltd. Shenzhen Guangdong Contract manufacturer 11
Curatia Medical Limited Suzhou Jiangsu Specification developer 5
Shenzhen Vivolight Medical Device&Technology Co., Ltd. Shenzhen Guangdong Manufacturer 4
Shenzhen Antmed Co., Ltd. Dongguan Guangdong Manufacturer 4

Record

Regulatory record for BCI
Listed by ICU Medical, Inc, United States
FDA product code DQO
Device type Catheter, Intravascular, Diagnostic
Device class Class 2
Regulation 21 CFR 870.1200
Establishment Contract manufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer
510(k) K893877
Record published 2016-10-13
Record revised 2025-04-16 (version 9)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Single use Yes
Prescription Prescription only
Latex Labelled latex-free
Label carries lot or batch number, manufacturing date

Catalogue Numbers

Catalogue numbers for BCI
Catalogue number Size Per pack Status
3137 100 In distribution
3043 In distribution
3135 50 In distribution
3134 50 In distribution
3044 In distribution
3049 20 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Performa® Merit Medical Systems, Inc. 1,101
Impress® Merit Medical Systems, Inc. 839
Super Torque Cordis Corp. 611
Soft-Vu AngioDynamics, Inc. 591
Torcon NB Cook Incorporated 463
Mariner AngioDynamics, Inc. 323
INT,SlideCath Shanghai Kindly Medical Instruments Co., Ltd. 264
Infiniti Cordis Corp. 251
Infiniti Cordis US Corp. 241
AngiOptic AngioDynamics, Inc. 227
Tempo Cordis Corp. 217
SiteSeer™ Medtronic, Inc. 204

Showing 12 of 226. All products under Catheter, Intravascular, Diagnostic

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K063784 2007-04-16
K052865 2005-12-22

Recalls

4 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2012-09-28 Class II Mixed-up of materials/components ICU Medical, Inc. has identified a potential comingling of components where a 60 drop micro drip
chamber may have been included on a 20 drop macro drip set.
60 2013-02-19
2012-04-17 Class II Nonconforming Material/Component The firm initiated the recall due to a molding defect in a high pressure stopcock where a small
percentage of the side ports could become totally occluded.
4625 2012-08-23
2012-04-17 Class II Nonconforming Material/Component The firm initiated the recall due to a molding defect in a high pressure stopcock where a small
percentage of the side ports could become totally occluded.
2012-08-23
2012-04-17 Class II Nonconforming Material/Component The firm initiated the recall due to a molding defect in a high pressure stopcock where a small
percentage of the side ports could become totally occluded.
2012-08-23
2004-11-02 Not classified Other Syringes could possibly allow air to enter the patient’s vascular system. 250 syringes 2005-07-25
2004-11-02 Not classified Other Syringes could possibly allow air to enter the patient’s vascular system. 62080 kits 2005-07-25
2004-11-02 Not classified Other Syringes could possibly allow air to enter the patient’s vascular system. 0 syringes 2005-07-25
2004-11-02 Not classified Other Syringes could possibly allow air to enter the patient’s vascular system. 2050 syringes 2005-07-25
2004-11-02 Not classified Other Syringes could possibly allow air to enter the patient’s vascular system. 8175 syringes 2005-07-25
2004-10-20 Not classified Other Sampling port bodies on the device are cracking which can allow the sampling site to become dislodged from the body. 71,132 units. 2012-04-11

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer