Beacon Tip Torcon NB
Beacon Tip Torcon NB Advantage is a single-lumen catheter used in angiographic procedures. It belongs to the Beacon Tip catheter family, which includes several distinct catheter designs.…
Beacon Tip Torcon NB Advantage is a single-lumen catheter used in angiographic procedures. It belongs to the Beacon Tip catheter family, which includes several distinct catheter designs. Each configuration has a Luer lock adapter, connecting cap and catheter shaft.
The catheter is intended for use by physicians trained and experienced in angiographic techniques. Placement uses standard techniques for vascular access sheaths, angiographic catheters and wire guides. The described catheter range includes vascular and nonvascular angiographic applications.
Listed Item
Beacon Tip Torcon NB Advantage Catheter
Single-Use Supply
Beacon Tip catheters are supplied sterile and intended for single use. Torcon NB Advantage is a catheter subfamily; the separately named Beacon Tip Sizing Catheters have additional gold marker bands for anatomical measurement. Those sizing features are specific to the sizing models.
Who Else Makes It
Concentrated in Jiangsu (5), Guangdong (3), Zhejiang (2). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| GE Medical Systems (China) Co., Ltd. | Wuxi | Jiangsu | Contract manufacturer | 57 |
| Amsino Medical (Kunshan) Co., Ltd. | Kunshan | Jiangsu | Contract manufacturer | 53 |
| Conod Medical Shuyang Co., Ltd. | Shuyang | Jiangsu | Contract manufacturer | 22 |
| Bioxin Medical Co., Ltd. | Weihai | Shandong | Contract manufacturer | 8 |
| GRI Medical & Electronic Technology Co., Ltd. | Jiaxing | Zhejiang | Contract manufacturer | 71 |
| Goals Sterilization Co., Ltd. | Jiaxing | Zhejiang | Contract manufacturer | 26 |
| Wuxi Goals Medical Technology Co., Ltd. | Yixing | Jiangsu | Contract manufacturer | 24 |
| Sunny Medical Device (Shenzhen) Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 11 |
| Curatia Medical Limited | Suzhou | Jiangsu | Specification developer | 5 |
| Shenzhen Vivolight Medical Device&Technology Co., Ltd. | Shenzhen | Guangdong | Manufacturer | 4 |
| Shenzhen Antmed Co., Ltd. | Dongguan | Guangdong | Manufacturer | 4 |
Record
| Listed by | Cook Incorporated, United States |
|---|---|
| FDA product code | DQO |
| Device type | Catheter, Intravascular, Diagnostic |
| Device class | Class 2 |
| Regulation | 21 CFR 870.1200 |
| Establishment | Contract manufacturer, Contract steriliser, Specification developer, Complaint-file establishment, Manufacturer, Exporter |
| 510(k) | K173289 |
| Record published | 2018-03-02 |
| Record revised | 2023-10-23 (version 3) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date, manufacturing date |
| Storage | Special storage condition: Store in dark, dry, cool place. Avoid extended exposure to light. |
| Packaging | Pack of 5 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| G24825 | In distribution | |
| G35733 | In distribution | |
| G11457 | In distribution | |
| G13783 | In distribution | |
| G08422 | In distribution | |
| G20038 | In distribution | |
| G31409 | In distribution | |
| G10028 | In distribution | |
| G09371 | In distribution | |
| G11652 | In distribution | |
| G08625 | In distribution | |
| G12595 | In distribution | |
| G13573 | In distribution | |
| G12899 | In distribution | |
| G08472 | In distribution | |
| G13561 | In distribution | |
| G09916 | In distribution | |
| G11202 | In distribution | |
| G57017 | In distribution | |
| G35734 | In distribution | |
| G11190 | In distribution | |
| G11886 | In distribution | |
| G11208 | In distribution | |
| G11205 | In distribution | |
| G11487 | In distribution | |
| G10082 | In distribution | |
| G27853 | In distribution | |
| G13795 | In distribution | |
| G11530 | In distribution | |
| G13563 | In distribution | |
| G11446 | In distribution | |
| G08446 | In distribution | |
| G13559 | In distribution | |
| G08677 | In distribution | |
| G11192 | In distribution | |
| G08443 | In distribution | |
| G09967 | In distribution | |
| G11469 | In distribution | |
| G08849 | In distribution | |
| G11203 | In distribution | |
| G08581 | In distribution | |
| G08805 | In distribution | |
| G11206 | In distribution | |
| G08582 | In distribution | |
| G09751 | In distribution | |
| G08420 | In distribution | |
| G08448 | In distribution | |
| G11189 | In distribution | |
| G09853 | In distribution | |
| G08596 | In distribution | |
| G08511 | In distribution | |
| G08586 | In distribution | |
| G08642 | In distribution | |
| G57015 | In distribution | |
| G08421 | In distribution | |
| G09312 | In distribution | |
| G08809 | In distribution | |
| G11378 | In distribution | |
| G11380 | In distribution | |
| G11414 | In distribution | |
| G11475 | In distribution | |
| G11199 | In distribution | |
| G27829 | In distribution | |
| G21042 | In distribution | |
| G27811 | In distribution | |
| G08597 | In distribution | |
| G08699 | In distribution | |
| G12715 | In distribution | |
| G13258 | In distribution | |
| G08583 | In distribution | |
| G31970 | In distribution | |
| G08469 | In distribution | |
| G13562 | In distribution | |
| G08623 | In distribution | |
| G08577 | In distribution | |
| G09741 | In distribution | |
| G08578 | In distribution | |
| G09469 | In distribution | |
| G12870 | In distribution | |
| G10080 | In distribution | |
| G08447 | In distribution | |
| G08441 | In distribution | |
| G11461 | In distribution | |
| G11471 | In distribution | |
| G09344 | In distribution | |
| G08442 | In distribution | |
| G11191 | In distribution | |
| G11458 | In distribution | |
| G12570 | In distribution | |
| G35735 | In distribution | |
| G13794 | In distribution | |
| G09548 | In distribution | |
| G08444 | In distribution | |
| G12170 | In distribution | |
| G27852 | In distribution | |
| G09654 | In distribution | |
| G11478 | In distribution | |
| G13119 | In distribution | |
| G12293 | In distribution | |
| G35737 | In distribution | |
| G13804 | In distribution | |
| G11459 | In distribution | |
| G11195 | In distribution | |
| G57016 | In distribution | |
| G11483 | In distribution | |
| G13711 | In distribution | |
| G11517 | In distribution | |
| G13703 | In distribution | |
| G11201 | In distribution | |
| G12072 | In distribution | |
| G11377 | In distribution | |
| G11470 | In distribution | |
| G08918 | In distribution | |
| G13560 | In distribution | |
| G11726 | In distribution | |
| G31408 | In distribution | |
| G08796 | In distribution | |
| G09899 | In distribution | |
| G11209 | In distribution | |
| G11194 | In distribution | |
| G20791 | In distribution | |
| G11204 | In distribution | |
| G11207 | In distribution | |
| G11200 | In distribution | |
| G11468 | In distribution | |
| G11658 | In distribution | |
| G11435 | In distribution | |
| G57018 | In distribution | |
| G11395 | In distribution | |
| G10063 | In distribution | |
| G35974 | In distribution | |
| G08917 | In distribution | |
| G11486 | In distribution | |
| G11642 | In distribution | |
| G32368 | In distribution | |
| G31410 | In distribution | |
| G11430 | In distribution | |
| G08471 | In distribution | |
| G11193 | In distribution | |
| G11484 | In distribution | |
| G08419 | In distribution | |
| G27815 | In distribution | |
| G11488 | In distribution | |
| G08641 | In distribution | |
| G08584 | In distribution | |
| G09888 | In distribution | |
| G11375 | In distribution | |
| G08470 | In distribution | |
| G13793 | In distribution | |
| G11460 | In distribution | |
| G08585 | In distribution | |
| G12154 | In distribution | |
| G13792 | In distribution | |
| G35736 | In distribution | |
| G11379 | In distribution | |
| G11467 | In distribution | |
| G11476 | In distribution | |
| G11437 | In distribution | |
| G11883 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Performa® | Merit Medical Systems, Inc. | 1,101 |
| Impress® | Merit Medical Systems, Inc. | 839 |
| Super Torque | Cordis Corp. | 611 |
| Soft-Vu | AngioDynamics, Inc. | 591 |
| Torcon NB | Cook Incorporated | 463 |
| Mariner | AngioDynamics, Inc. | 323 |
| INT,SlideCath | Shanghai Kindly Medical Instruments Co., Ltd. | 264 |
| Infiniti | Cordis Corp. | 251 |
| Infiniti | Cordis US Corp. | 241 |
| AngiOptic | AngioDynamics, Inc. | 227 |
| Tempo | Cordis Corp. | 217 |
| SiteSeer™ | Medtronic, Inc. | 204 |
Showing 12 of 226. All products under Catheter, Intravascular, Diagnostic
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K181722 | 2019-03-22 |
| K180846 | 2018-12-19 |
| K180792 | 2018-11-30 |
| K180286 | 2018-10-26 |
| K180054 | 2018-10-05 |
| K172635 | 2018-04-03 |
| K171264 | 2018-01-25 |
| K173289 | 2017-11-15 |
| K162448 | 2017-05-26 |
| K161822 | 2016-10-27 |
| K133130 | 2015-01-09 |
| K122937 | 2012-12-14 |
| K002254 | 2001-03-16 |
| K974774 | 1998-10-16 |
| K882796 | 1988-07-28 |
Recalls Naming This Product
2 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|---|---|
| Cook Incorporated | 510(k) number | 2026-04-02 | Class I | Under Investigation by firm | Marker bands may be at an increased risk of cracking/breakage. Potential adverse events that may result include increased procedural time, harms associated with device fragmentation/separation, and vessel injury. In a worst-case scenario, d | 4,245 |
| Cook Incorporated | 510(k) number | 2025-05-15 | Class I | Process change control | Cook Medical identified that catheters supplied in the affected device lots may experience tip separation. | 26986 units |
Recalls
2 of these are Class I. Class I is the FDA’s most serious grade: a reasonable probability of serious injury or death. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2026-04-02 | Class I | Under Investigation by firm | Marker bands may be at an increased risk of cracking/breakage. Potential adverse events that may result include increased procedural time, harms associated with device fragmentation/separation, and vessel injury. In a worst-case scenario, d | 271 | |
| 2026-04-02 | Class I | Under Investigation by firm | Marker bands may be at an increased risk of cracking/breakage. Potential adverse events that may result include increased procedural time, harms associated with device fragmentation/separation, and vessel injury. In a worst-case scenario, d | 11,253 | |
| 2026-03-05 | Class II | Incorrect or no expiration date | Products from the affected device lots were labeled with expiration dates that exceed the true shelf life. | 20 units | |
| 2019-10-21 | Class II | Process change control | The potential compromise of the sterility of products from an undersealed chevron in the packaging pouches of Torcon NB Advantage Catheters. | 5 | 2020-06-30 |
| 2019-10-21 | Class II | Process change control | The potential compromise of the sterility of products from an undersealed chevron in the packaging pouches of Torcon NB Advantage Catheters. | 35 | 2020-06-30 |
| 2019-10-21 | Class II | Process change control | The potential compromise of the sterility of products from an undersealed chevron in the packaging pouches of Torcon NB Advantage Catheters. | 265 | 2020-06-30 |
| 2019-10-21 | Class II | Process change control | The potential compromise of the sterility of products from an undersealed chevron in the packaging pouches of Torcon NB Advantage Catheters. | 10 | 2020-06-30 |
| 2019-10-21 | Class II | Process change control | The potential compromise of the sterility of products from an undersealed chevron in the packaging pouches of Torcon NB Advantage Catheters. | 30 | 2020-06-30 |
| 2019-10-21 | Class II | Process change control | The potential compromise of the sterility of products from an undersealed chevron in the packaging pouches of Torcon NB Advantage Catheters. | 30 | 2020-06-30 |
| 2019-10-21 | Class II | Process change control | The potential compromise of the sterility of products from an undersealed chevron in the packaging pouches of Torcon NB Advantage Catheters. | 5 | 2020-06-30 |
| 2019-10-21 | Class II | Process change control | The potential compromise of the sterility of products from an undersealed chevron in the packaging pouches of Torcon NB Advantage Catheters. | 145 | 2020-06-30 |
| 2019-10-21 | Class II | Process change control | The potential compromise of the sterility of products from an undersealed chevron in the packaging pouches of Torcon NB Advantage Catheters. | 100 | 2020-06-30 |
| 2019-10-21 | Class II | Process change control | The potential compromise of the sterility of products from an undersealed chevron in the packaging pouches of Torcon NB Advantage Catheters. | 90 | 2020-06-30 |
| 2019-10-21 | Class II | Process change control | The potential compromise of the sterility of products from an undersealed chevron in the packaging pouches of Torcon NB Advantage Catheters. | 10 | 2020-06-30 |
| 2019-10-21 | Class II | Process change control | The potential compromise of the sterility of products from an undersealed chevron in the packaging pouches of Torcon NB Advantage Catheters. | 20 | 2020-06-30 |
| 2019-10-21 | Class II | Process change control | The potential compromise of the sterility of products from an undersealed chevron in the packaging pouches of Torcon NB Advantage Catheters. | 35 | 2020-06-30 |
| 2019-10-21 | Class II | Process change control | The potential compromise of the sterility of products from an undersealed chevron in the packaging pouches of Torcon NB Advantage Catheters. | 25 | 2020-06-30 |
| 2019-10-21 | Class II | Process change control | The potential compromise of the sterility of products from an undersealed chevron in the packaging pouches of Torcon NB Advantage Catheters. | 10 | 2020-06-30 |
| 2019-10-21 | Class II | Process change control | The potential compromise of the sterility of products from an undersealed chevron in the packaging pouches of Torcon NB Advantage Catheters. | 1,679 | 2020-06-30 |
| 2019-10-21 | Class II | Process change control | The potential compromise of the sterility of products from an undersealed chevron in the packaging pouches of Torcon NB Advantage Catheters. | 33 | 2020-06-30 |
| 2019-10-21 | Class II | Process change control | The potential compromise of the sterility of products from an undersealed chevron in the packaging pouches of Torcon NB Advantage Catheters. | 98 | 2020-06-30 |
| 2019-10-21 | Class II | Process change control | The potential compromise of the sterility of products from an undersealed chevron in the packaging pouches of Torcon NB Advantage Catheters. | 35 | 2020-06-30 |
| 2019-10-21 | Class II | Process change control | The potential compromise of the sterility of products from an undersealed chevron in the packaging pouches of Torcon NB Advantage Catheters. | 5 | 2020-06-30 |
| 2019-10-21 | Class II | Process change control | The potential compromise of the sterility of products from an undersealed chevron in the packaging pouches of Torcon NB Advantage Catheters. | 10 | 2020-06-30 |
| 2019-10-21 | Class II | Process change control | The potential compromise of the sterility of products from an undersealed chevron in the packaging pouches of Torcon NB Advantage Catheters. | 5 | 2020-06-30 |
| 2019-10-21 | Class II | Process change control | The potential compromise of the sterility of products from an undersealed chevron in the packaging pouches of Torcon NB Advantage Catheters. | 195 | 2020-06-30 |
| 2019-10-21 | Class II | Process change control | The potential compromise of the sterility of products from an undersealed chevron in the packaging pouches of Torcon NB Advantage Catheters. | 5 | 2020-06-30 |
| 2019-10-21 | Class II | Process change control | The potential compromise of the sterility of products from an undersealed chevron in the packaging pouches of Torcon NB Advantage Catheters. | 250 | 2020-06-30 |
| 2019-10-21 | Class II | Process change control | The potential compromise of the sterility of products from an undersealed chevron in the packaging pouches of Torcon NB Advantage Catheters. | 30 | 2020-06-30 |
| 2019-10-21 | Class II | Process change control | The potential compromise of the sterility of products from an undersealed chevron in the packaging pouches of Torcon NB Advantage Catheters. | 60 | 2020-06-30 |
| 2019-10-21 | Class II | Process change control | The potential compromise of the sterility of products from an undersealed chevron in the packaging pouches of Torcon NB Advantage Catheters. | 232 | 2020-06-30 |
| 2019-10-21 | Class II | Process change control | The potential compromise of the sterility of products from an undersealed chevron in the packaging pouches of Torcon NB Advantage Catheters. | 5 | 2020-06-30 |
| 2019-10-21 | Class II | Process change control | The potential compromise of the sterility of products from an undersealed chevron in the packaging pouches of Torcon NB Advantage Catheters. | 165 | 2020-06-30 |
| 2019-10-21 | Class II | Process change control | The potential compromise of the sterility of products from an undersealed chevron in the packaging pouches of Torcon NB Advantage Catheters. | 311 | 2020-06-30 |
| 2019-10-21 | Class II | Process change control | The potential compromise of the sterility of products from an undersealed chevron in the packaging pouches of Torcon NB Advantage Catheters. | 951 | 2020-06-30 |
| 2019-10-21 | Class II | Process change control | The potential compromise of the sterility of products from an undersealed chevron in the packaging pouches of Torcon NB Advantage Catheters. | 5 | 2020-06-30 |
| 2019-10-21 | Class II | Process change control | The potential compromise of the sterility of products from an undersealed chevron in the packaging pouches of Torcon NB Advantage Catheters. | 20 | 2020-06-30 |
| 2019-10-21 | Class II | Process change control | The potential compromise of the sterility of products from an undersealed chevron in the packaging pouches of Torcon NB Advantage Catheters. | 25 | 2020-06-30 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.