Coeur
72 in. (1828mm) High Pressure Line with Rotating Adapter
11manufacturers in China registered for this device type
6catalogue numbers in this listing
1510(k) clearance
Who Else Makes It
Concentrated in Jiangsu (5), Guangdong (3), Zhejiang (2). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| GE Medical Systems (China) Co., Ltd. | Wuxi | Jiangsu | Contract manufacturer | 57 |
| Amsino Medical (Kunshan) Co., Ltd. | Kunshan | Jiangsu | Contract manufacturer | 53 |
| Conod Medical Shuyang Co., Ltd. | Shuyang | Jiangsu | Contract manufacturer | 22 |
| Bioxin Medical Co., Ltd. | Weihai | Shandong | Contract manufacturer | 8 |
| GRI Medical & Electronic Technology Co., Ltd. | Jiaxing | Zhejiang | Contract manufacturer | 71 |
| Goals Sterilization Co., Ltd. | Jiaxing | Zhejiang | Contract manufacturer | 26 |
| Wuxi Goals Medical Technology Co., Ltd. | Yixing | Jiangsu | Contract manufacturer | 24 |
| Sunny Medical Device (Shenzhen) Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 11 |
| Curatia Medical Limited | Suzhou | Jiangsu | Specification developer | 5 |
| Shenzhen Vivolight Medical Device&Technology Co., Ltd. | Shenzhen | Guangdong | Manufacturer | 4 |
| Shenzhen Antmed Co., Ltd. | Dongguan | Guangdong | Manufacturer | 4 |
Record
| Listed by | Coeur, Inc., United States |
|---|---|
| FDA product code | DQO |
| Device type | Catheter, Intravascular, Diagnostic |
| Device class | Class 2 |
| Regulation | 21 CFR 870.1200 |
| 510(k) | K071196 |
| Record published | 2016-07-14 |
| Record revised | 2019-02-04 (version 3) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date |
| Storage | Special storage condition: Keep product in clean, dry location. Avoid direct rays, heat and high humidity, and ultraviolet rays such as a germicida |
| Packaging | Shipper of 2, case of 25, case of 50 |
| Sizes | Length 48 to 72 in; length 1200 to 1828 mm |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| C403-0481 | Length 48 in | In distribution |
| C403-0721 | Length 1828 mm | In distribution |
| C403-0480 | Length 48 in | In distribution |
| C403-0600 | Length 1500 mm | In distribution |
| C403-0720 | Length 1828 mm | In distribution |
| C403-0601 | Length 1500 mm | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Performa® | Merit Medical Systems, Inc. | 1,101 |
| Impress® | Merit Medical Systems, Inc. | 839 |
| Super Torque | Cordis Corp. | 611 |
| Soft-Vu | AngioDynamics, Inc. | 591 |
| Torcon NB | Cook Incorporated | 463 |
| Mariner | AngioDynamics, Inc. | 323 |
| INT,SlideCath | Shanghai Kindly Medical Instruments Co., Ltd. | 264 |
| Infiniti | Cordis Corp. | 251 |
| Infiniti | Cordis US Corp. | 241 |
| AngiOptic | AngioDynamics, Inc. | 227 |
| Tempo | Cordis Corp. | 217 |
| SiteSeer™ | Medtronic, Inc. | 204 |
Showing 12 of 226. All products under Catheter, Intravascular, Diagnostic
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K071196 | 2007-09-06 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.