Cordis

7F HF.038 Inches 100CM 4SH Grollman

Registry build 21.09.26
11manufacturers in China registered for this device type
28catalogue numbers in this listing
1510(k) clearance
10recalls on this code

Who Else Makes It

Concentrated in Jiangsu (5), Guangdong (3), Zhejiang (2). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code DQO
Manufacturer City Province Registered as Device types
GE Medical Systems (China) Co., Ltd. Wuxi Jiangsu Contract manufacturer 57
Amsino Medical (Kunshan) Co., Ltd. Kunshan Jiangsu Contract manufacturer 53
Conod Medical Shuyang Co., Ltd. Shuyang Jiangsu Contract manufacturer 22
Bioxin Medical Co., Ltd. Weihai Shandong Contract manufacturer 8
GRI Medical & Electronic Technology Co., Ltd. Jiaxing Zhejiang Contract manufacturer 71
Goals Sterilization Co., Ltd. Jiaxing Zhejiang Contract manufacturer 26
Wuxi Goals Medical Technology Co., Ltd. Yixing Jiangsu Contract manufacturer 24
Sunny Medical Device (Shenzhen) Co., Ltd. Shenzhen Guangdong Contract manufacturer 11
Curatia Medical Limited Suzhou Jiangsu Specification developer 5
Shenzhen Vivolight Medical Device&Technology Co., Ltd. Shenzhen Guangdong Manufacturer 4
Shenzhen Antmed Co., Ltd. Dongguan Guangdong Manufacturer 4

Record

Regulatory record for Cordis
Listed by Cordis US Corp., United States
FDA product code DQO
Device type Catheter, Intravascular, Diagnostic
Device class Class 2
Regulation 21 CFR 870.1200
Establishment Specification developer, Complaint-file establishment, Manufacturer, Exporter
510(k) K862006
Record published 2016-08-01
Record revised 2025-09-05 (version 8)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Latex Labelled latex-free
Label carries lot or batch number, expiry date
Storage Storage environment temperature 15 to 30 °C
Packaging Box of 5, inch of 5

Catalogue Numbers

Catalogue numbers for Cordis
Catalogue number Size Per pack Status
SR3240 In distribution
SRD6608 In distribution
SRD6822 In distribution
67000490 In distribution
SRD5880 In distribution
67000300 In distribution
527750S In distribution
SRD7024 5 In distribution
67000500 In distribution
SRD7052 In distribution
MODA06321 In distribution
SM7700 In distribution
67000800 In distribution
527754S In distribution
67000600 In distribution
533553 In distribution
SRD5871 In distribution
SRD5624 In distribution
67000200 In distribution
533550 In distribution
533552 In distribution
SRD5929 In distribution
533527 In distribution
SRD6639 In distribution
SM7697 In distribution
67000400 In distribution
SRD7023 5 In distribution
SRD5632 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Performa® Merit Medical Systems, Inc. 1,101
Impress® Merit Medical Systems, Inc. 839
Super Torque Cordis Corp. 611
Soft-Vu AngioDynamics, Inc. 591
Torcon NB Cook Incorporated 463
Mariner AngioDynamics, Inc. 323
INT,SlideCath Shanghai Kindly Medical Instruments Co., Ltd. 264
Infiniti Cordis Corp. 251
Infiniti Cordis US Corp. 241
AngiOptic AngioDynamics, Inc. 227
Tempo Cordis Corp. 217
SiteSeer™ Medtronic, Inc. 204

Showing 12 of 226. All products under Catheter, Intravascular, Diagnostic

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K232573 2023-11-21

Recalls Naming This Product

3 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of Cordis
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Cordis US Corp. 510(k) number 2023-09-26 Class I Process control Non-sterile product labeled as sterile was distributed. 30 devices
Cordis US Corp. 510(k) number 2022-11-07 Class II Under Investigation by firm There is a potential for separation at the male connector. 16,950 units (2,915 US and 14,000 OUS)
Cordis US Corp. 510(k) number 2006-06-26 Not classified Other The tip of the catheter may separate from the body during operation. 338,270 2008-11-19

Recalls

5 of these are Class I. Class I is the FDA’s most serious grade: a reasonable probability of serious injury or death. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2021-07-21 Class I Device Design Cordis has identified that the SUPER TORQUE MB Angiographic Catheter (with Marker Bands) are being used in a manner that may allow entrapment of the catheter between endovascular devices and the vessel wall, which can lead to marker band mo 45 units 2024-09-09
2021-07-21 Class I Device Design Cordis has identified that the SUPER TORQUE MB Angiographic Catheter (with Marker Bands) are being used in a manner that may allow entrapment of the catheter between endovascular devices and the vessel wall, which can lead to marker band mo 71330 units 2024-09-09
2021-07-21 Class I Device Design Cordis has identified that the SUPER TORQUE MB Angiographic Catheter (with Marker Bands) are being used in a manner that may allow entrapment of the catheter between endovascular devices and the vessel wall, which can lead to marker band mo 1610 units 2024-09-09
2021-07-21 Class I Device Design Cordis has identified that the SUPER TORQUE MB Angiographic Catheter (with Marker Bands) are being used in a manner that may allow entrapment of the catheter between endovascular devices and the vessel wall, which can lead to marker band mo 18730 units 2024-09-09
2021-07-21 Class I Device Design Cordis has identified that the SUPER TORQUE MB Angiographic Catheter (with Marker Bands) are being used in a manner that may allow entrapment of the catheter between endovascular devices and the vessel wall, which can lead to marker band mo 26025 units 2024-09-09
2011-11-21 Not classified Error in labeling Cordis Corporation is issuing a Correction for their SUPER TORQUE MB Angiographic Catheter after receiving a report of marker bands dislodged during a procedure. Model Numbers 532598A, 532598B, 532598C, 532598D, SRD5724MB and SRD5727MB are 118,690 units 2013-07-23
2011-11-21 Not classified Error in labeling Cordis Corporation is issuing a Correction for their SUPER TORQUE MB Angiographic Catheter after receiving a report of marker bands dislodged during a procedure. Model Numbers 532598A, 532598B, 532598C, 532598D, SRD5724MB and SRD5727MB are 310 units 2013-07-23

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer