ICU Medical
Cath Lab Kit w/Waste Bag System, 3 Port "ON" Manifold (600 psi), dyePod™, Transpac™ IV, 12 cc Control Syringe, Syringes and Guidewire
Who Else Makes It
Concentrated in Jiangsu (5), Guangdong (3), Zhejiang (2). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| GE Medical Systems (China) Co., Ltd. | Wuxi | Jiangsu | Contract manufacturer | 57 |
| Amsino Medical (Kunshan) Co., Ltd. | Kunshan | Jiangsu | Contract manufacturer | 53 |
| Conod Medical Shuyang Co., Ltd. | Shuyang | Jiangsu | Contract manufacturer | 22 |
| Bioxin Medical Co., Ltd. | Weihai | Shandong | Contract manufacturer | 8 |
| GRI Medical & Electronic Technology Co., Ltd. | Jiaxing | Zhejiang | Contract manufacturer | 71 |
| Goals Sterilization Co., Ltd. | Jiaxing | Zhejiang | Contract manufacturer | 26 |
| Wuxi Goals Medical Technology Co., Ltd. | Yixing | Jiangsu | Contract manufacturer | 24 |
| Sunny Medical Device (Shenzhen) Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 11 |
| Curatia Medical Limited | Suzhou | Jiangsu | Specification developer | 5 |
| Shenzhen Vivolight Medical Device&Technology Co., Ltd. | Shenzhen | Guangdong | Manufacturer | 4 |
| Shenzhen Antmed Co., Ltd. | Dongguan | Guangdong | Manufacturer | 4 |
Record
| Listed by | ICU Medical, Inc, United States |
|---|---|
| FDA product code | DQO |
| Device type | Catheter, Intravascular, Diagnostic |
| Device class | Class 2 |
| Regulation | 21 CFR 870.1200 |
| Establishment | Contract manufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer |
| 510(k) | K932141 |
| Record published | 2021-08-29 |
| Record revised | 2019-01-23 (version 5) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Supplied as a kit | Yes |
| Latex | Labelled latex-free |
| Label carries | lot or batch number, expiry date |
| Packaging | Case of 25, case of 10, case of 20, case of 5, case of 50, case of 15 |
| UDI direct marking | Exempt |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 42370-01 | In distribution | |
| 42044-01 | In distribution | |
| 46093-36 | In distribution | |
| 42366-01 | In distribution | |
| 42343-02 | In distribution | |
| AG7801 | In distribution | |
| 46047-19 | In distribution | |
| AG7420 | In distribution | |
| 46096-26 | In distribution | |
| AG7986 | In distribution | |
| 46066-33 | In distribution | |
| 42386-01 | In distribution | |
| 46111-12 | In distribution | |
| 46073-17 | In distribution | |
| 46105-87 | In distribution | |
| 42341-02 | In distribution | |
| 46084-61 | In distribution | |
| 42041-01 | In distribution | |
| 46100-79 | In distribution | |
| 42376-01 | In distribution | |
| 46200-25 | In distribution | |
| 46099-57 | In distribution | |
| AG8020 | In distribution | |
| 46997-01 | In distribution | |
| 46093-25 | In distribution | |
| 46102-62 | In distribution | |
| 46084-10 | In distribution | |
| AG8095 | In distribution | |
| 42348-48 | In distribution | |
| 46050-24 | In distribution | |
| 46075-61 | In distribution | |
| 46095-56 | In distribution | |
| 46100-85 | In distribution | |
| 46096-45 | In distribution | |
| 42400-02 | In distribution | |
| 46078-52 | In distribution | |
| 42364-01 | In distribution | |
| 42317-01 | In distribution | |
| 42362-11 | In distribution | |
| AG8088 | In distribution | |
| 46073-70 | In distribution | |
| 46098-22 | In distribution | |
| 46098-96 | In distribution | |
| 46083-02 | In distribution | |
| B1473 | In distribution | |
| 42375-01 | In distribution | |
| 46056-36 | In distribution | |
| AG7891 | In distribution | |
| AG8019 | In distribution | |
| 42478-02 | In distribution | |
| 42052-01 | In distribution | |
| 42387-01 | In distribution | |
| 46098-94 | In distribution | |
| 46100-92 | In distribution | |
| 46071-40 | In distribution | |
| AG8053 | In distribution | |
| AG7398 | In distribution | |
| 46055-07 | In distribution | |
| 46100-99 | In distribution | |
| 46098-66 | In distribution | |
| 46078-17 | In distribution | |
| 42385-01 | In distribution | |
| 46098-35 | In distribution | |
| 46089-03 | In distribution | |
| 46050-58 | In distribution | |
| 46100-91 | In distribution | |
| 46096-25 | In distribution | |
| 46056-35 | In distribution | |
| 42436-01 | In distribution | |
| 46063-37 | In distribution | |
| 46071-63 | In distribution | |
| AG8074 | In distribution | |
| AG8021 | In distribution | |
| 46300-11 | In distribution | |
| 42432-48 | In distribution | |
| 46080-02 | In distribution | |
| 42900-03 | In distribution | |
| 46089-74 | In distribution | |
| 46100-29 | In distribution | |
| 46096-86 | In distribution | |
| 46066-13 | In distribution | |
| 42409-11 | In distribution | |
| 42342-02 | In distribution | |
| 46073-18 | In distribution | |
| 42610-45 | In distribution | |
| 42402-02 | In distribution | |
| 42398-01 | In distribution | |
| 46066-34 | In distribution | |
| 46098-16 | In distribution | |
| 46098-76 | In distribution | |
| 42901-02 | In distribution | |
| 46100-87 | In distribution | |
| 42372-01 | In distribution | |
| 46095-16 | In distribution | |
| 46057-18 | In distribution | |
| AG8075 | In distribution | |
| 46105-84 | In distribution | |
| 46069-61 | In distribution | |
| 46095-66 | In distribution | |
| AG7394 | In distribution | |
| 46300-50 | In distribution | |
| 46111-39 | In distribution | |
| 42377-01 | In distribution | |
| 42384-11 | In distribution | |
| 46095-22 | In distribution | |
| 46098-86 | In distribution | |
| 46100-83 | In distribution | |
| AG7878 | In distribution | |
| 42435-01 | In distribution | |
| 42374-01 | In distribution | |
| AG8137 | In distribution | |
| 42368-01 | In distribution | |
| 46098-56 | In distribution | |
| AG8131 | In distribution | |
| 42388-01 | In distribution | |
| 46083-11 | In distribution | |
| 46098-75 | In distribution | |
| 46078-16 | In distribution | |
| 42373-01 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Performa® | Merit Medical Systems, Inc. | 1,101 |
| Impress® | Merit Medical Systems, Inc. | 839 |
| Super Torque | Cordis Corp. | 611 |
| Soft-Vu | AngioDynamics, Inc. | 591 |
| Torcon NB | Cook Incorporated | 463 |
| Mariner | AngioDynamics, Inc. | 323 |
| INT,SlideCath | Shanghai Kindly Medical Instruments Co., Ltd. | 264 |
| Infiniti | Cordis Corp. | 251 |
| Infiniti | Cordis US Corp. | 241 |
| AngiOptic | AngioDynamics, Inc. | 227 |
| Tempo | Cordis Corp. | 217 |
| SiteSeer™ | Medtronic, Inc. | 204 |
Showing 12 of 226. All products under Catheter, Intravascular, Diagnostic
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K063784 | 2007-04-16 |
| K052865 | 2005-12-22 |
Recalls Naming This Product
4 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| ICU Medical, Inc | 510(k) number | 2012-04-17 | Class II | Nonconforming Material/Component | The firm initiated the recall due to a molding defect in a high pressure stopcock where a small percentage of the side ports could become totally occluded. | 4625 | 2012-08-23 |
| ICU Medical, Inc | 510(k) number | 2012-04-17 | Class II | Nonconforming Material/Component | The firm initiated the recall due to a molding defect in a high pressure stopcock where a small percentage of the side ports could become totally occluded. | 2012-08-23 | |
| ICU Medical, Inc | 510(k) number | 2012-04-17 | Class II | Nonconforming Material/Component | The firm initiated the recall due to a molding defect in a high pressure stopcock where a small percentage of the side ports could become totally occluded. | 2012-08-23 | |
| ICU Medical, Inc | 510(k) number | 2004-11-02 | Not classified | Other | Syringes could possibly allow air to enter the patient’s vascular system. | 62080 kits | 2005-07-25 |
Recalls
1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2012-09-28 | Class II | Mixed-up of materials/components | ICU Medical, Inc. has identified a potential comingling of components where a 60 drop micro drip chamber may have been included on a 20 drop macro drip set. | 60 | 2013-02-19 |
| 2004-11-02 | Not classified | Other | Syringes could possibly allow air to enter the patient’s vascular system. | 250 syringes | 2005-07-25 |
| 2004-11-02 | Not classified | Other | Syringes could possibly allow air to enter the patient’s vascular system. | 0 syringes | 2005-07-25 |
| 2004-11-02 | Not classified | Other | Syringes could possibly allow air to enter the patient’s vascular system. | 2050 syringes | 2005-07-25 |
| 2004-11-02 | Not classified | Other | Syringes could possibly allow air to enter the patient’s vascular system. | 8175 syringes | 2005-07-25 |
| 2004-10-20 | Not classified | Other | Sampling port bodies on the device are cracking which can allow the sampling site to become dislodged from the body. | 71,132 units. | 2012-04-11 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.