Lehman™

WVN Cath 001264 10PK 5400 7 125 Lehman

Registry build 21.09.26
11manufacturers in China registered for this device type
16catalogue numbers in this listing

Who Else Makes It

Concentrated in Jiangsu (5), Guangdong (3), Zhejiang (2). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code DQO
Manufacturer City Province Registered as Device types
GE Medical Systems (China) Co., Ltd. Wuxi Jiangsu Contract manufacturer 57
Amsino Medical (Kunshan) Co., Ltd. Kunshan Jiangsu Contract manufacturer 53
Conod Medical Shuyang Co., Ltd. Shuyang Jiangsu Contract manufacturer 22
Bioxin Medical Co., Ltd. Weihai Shandong Contract manufacturer 8
GRI Medical & Electronic Technology Co., Ltd. Jiaxing Zhejiang Contract manufacturer 71
Goals Sterilization Co., Ltd. Jiaxing Zhejiang Contract manufacturer 26
Wuxi Goals Medical Technology Co., Ltd. Yixing Jiangsu Contract manufacturer 24
Sunny Medical Device (Shenzhen) Co., Ltd. Shenzhen Guangdong Contract manufacturer 11
Curatia Medical Limited Suzhou Jiangsu Specification developer 5
Shenzhen Vivolight Medical Device&Technology Co., Ltd. Shenzhen Guangdong Manufacturer 4
Shenzhen Antmed Co., Ltd. Dongguan Guangdong Manufacturer 4

Record

Regulatory record for Lehman™
Listed by Medtronic, Inc., United States
FDA product code DQO
Device type Catheter, Intravascular, Diagnostic
Device class Class 2
Regulation 21 CFR 870.1200
Establishment Specification developer, Repacker / relabeller, Manufacturer, Exporter
Premarket notification Exempt
Record published 2019-02-03
Record revised 2026-06-01 (version 3)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number
Storage Special storage condition: Store catheters in a cool, dry area.
Packaging Pack of 10
Sizes Catheter gauge 5 to 8 Fr; lumen/inner diameter 0.889 to 1.753 mm; length 50 to 125 cm
Distribution end date 2026-05-28

Catalogue Numbers

Catalogue numbers for Lehman™
Catalogue number Size Status
001253 Catheter Gauge 5.0 Fr Withdrawn
001259 Lumen/Inner Diameter 1.194 mm Withdrawn
001260 Lumen/Inner Diameter 1.194 mm Withdrawn
001267 Length 125.0 cm Withdrawn
001254 Lumen/Inner Diameter 0.889 mm Withdrawn
001253 Length 50.0 cm Withdrawn
001254 Length 80.0 cm Withdrawn
001264 Length 125.0 cm Withdrawn
001260 Catheter Gauge 6.0 Fr Withdrawn
001263 Catheter Gauge 7.0 Fr Withdrawn
001267 Catheter Gauge 8.0 Fr Withdrawn
001263 Lumen/Inner Diameter 1.499 mm Withdrawn
990101 Length 80.0 cm Withdrawn
990101 Catheter Gauge 6.0 Fr Withdrawn
001264 Catheter Gauge 7.0 Fr Withdrawn
001259 Length 100.0 cm Withdrawn

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Performa® Merit Medical Systems, Inc. 1,101
Impress® Merit Medical Systems, Inc. 839
Super Torque Cordis Corp. 611
Soft-Vu AngioDynamics, Inc. 591
Torcon NB Cook Incorporated 463
Mariner AngioDynamics, Inc. 323
INT,SlideCath Shanghai Kindly Medical Instruments Co., Ltd. 264
Infiniti Cordis Corp. 251
Infiniti Cordis US Corp. 241
AngiOptic AngioDynamics, Inc. 227
Tempo Cordis Corp. 217
SiteSeer™ Medtronic, Inc. 204

Showing 12 of 226. All products under Catheter, Intravascular, Diagnostic

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer