Namic

MTO Arterial EXT. SET 6.625 PED- OEM PG

Registry build 21.09.26
11manufacturers in China registered for this device type
107catalogue numbers in this listing
3510(k) clearances naming this product code

Who Else Makes It

Concentrated in Jiangsu (5), Guangdong (3), Zhejiang (2). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code DQO
Manufacturer City Province Registered as Device types
GE Medical Systems (China) Co., Ltd. Wuxi Jiangsu Contract manufacturer 57
Amsino Medical (Kunshan) Co., Ltd. Kunshan Jiangsu Contract manufacturer 53
Conod Medical Shuyang Co., Ltd. Shuyang Jiangsu Contract manufacturer 22
Bioxin Medical Co., Ltd. Weihai Shandong Contract manufacturer 8
GRI Medical & Electronic Technology Co., Ltd. Jiaxing Zhejiang Contract manufacturer 71
Goals Sterilization Co., Ltd. Jiaxing Zhejiang Contract manufacturer 26
Wuxi Goals Medical Technology Co., Ltd. Yixing Jiangsu Contract manufacturer 24
Sunny Medical Device (Shenzhen) Co., Ltd. Shenzhen Guangdong Contract manufacturer 11
Curatia Medical Limited Suzhou Jiangsu Specification developer 5
Shenzhen Vivolight Medical Device&Technology Co., Ltd. Shenzhen Guangdong Manufacturer 4
Shenzhen Antmed Co., Ltd. Dongguan Guangdong Manufacturer 4

Record

Regulatory record for Namic
Listed by Medline Industries, Inc., United States
FDA product code DQO
Device type Catheter, Intravascular, Diagnostic
Device class Class 2
Regulation 21 CFR 870.1200
Record published 2021-07-26
Record revised 2026-02-26 (version 10)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Ethylene Oxide
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Latex Labelled latex-free
Label carries lot or batch number, expiry date, manufacturing date
Packaging Box of 25, box of 500, case of 25, case of 50, box of 10, case of 500
Sizes Length 4.5 to 72 in; pressure 200 to 1200 psi
UDI direct marking Exempt

Catalogue Numbers

Catalogue numbers for Namic
Catalogue number Size Per pack Status
70015320 Length 20 in In distribution
81011102 FALSE 100 In distribution
91031203 Length 20 in In distribution
91051602 Length 60 in In distribution
90703062 Length 6 in In distribution
81051202 FALSE 100 In distribution
91021202 Length 20 in In distribution
88001603 FALSE 50 In distribution
91051722 Length 72 in In distribution
80703050 FALSE 100 In distribution
81011482 FALSE 100 In distribution
81021102 FALSE 100 In distribution
80703122 FALSE 100 In distribution
91011302 Length 30 in In distribution
91001483 Pressure 1000 psi In distribution
91031482 Length 48 in In distribution
80515111 FALSE 100 In distribution
91001203 Pressure 1000 psi In distribution
81021302 FALSE 100 In distribution
91051203 Length 20 in In distribution
91051303 Length 30 in In distribution
91031483 Length 48 in In distribution
80515251 FALSE 100 In distribution
81051203 FALSE 100 In distribution
92031102 Pressure 1200 psi In distribution
70015312 Pressure 200 psi In distribution
81021202 FALSE 100 In distribution
92051482 Pressure 1200 psi In distribution
92051103 Pressure 1200 psi In distribution
81051102 FALSE 100 In distribution
91001103 Length 10 in In distribution
91500028 In distribution
92051602 Pressure 1200 psi In distribution
88001483 FALSE 100 In distribution
70015333 Pressure 200 psi In distribution
81051483 FALSE 100 In distribution
81011202 FALSE 100 In distribution
92031302 Length 30 in In distribution
92031203 Length 20 in In distribution
90703092 Length 9 in In distribution
81051042 FALSE 500 In distribution
92031483 Pressure 1200 psi In distribution
81031303 FALSE 100 In distribution
88001103 FALSE 100 In distribution
92051722 Length 72 in In distribution
88001203 FALSE 100 In distribution
81031302 FALSE 100 In distribution
92051483 Length 48 in In distribution
91031302 Length 30 in In distribution
92051603 Pressure 1200 psi In distribution
91011202 Pressure 1000 psi In distribution
90500040 In distribution
92031103 Pressure 1200 psi In distribution
81031483 FALSE 100 In distribution
91051102 Pressure 1200 psi In distribution
81031202 FALSE 100 In distribution
DYNJPMTBG36MF In distribution
91021102 Pressure 1000 psi In distribution
91021302 Pressure 500 psi In distribution
92051202 Length 20 in In distribution
91051202 Length 20 in In distribution
92051723 Pressure 1200 psi In distribution
91051483 Length 48 in In distribution
91031303 Pressure 1200 psi In distribution
70015412 Length 12 in In distribution
92031303 Pressure 1200 psi In distribution
91031202 Length 20 in In distribution
81031482 FALSE 100 In distribution
81051103 FALSE 100 In distribution
91001303 Length 30 in In distribution
91011602 Length 60 in In distribution
90703050 Length 4.5 in In distribution
92051203 Length 20 in In distribution
91011102 Length 10 in In distribution
92031482 Pressure 1200 psi In distribution
91031103 Length 10 in In distribution
70015433 Length 33 in In distribution
88001303 FALSE 100 In distribution
81051302 FALSE 100 In distribution
92051102 Length 10 in In distribution
81031203 FALSE 100 In distribution
92051303 Pressure 1200 psi In distribution
91051723 Length 72 in In distribution
91031102 Pressure 1200 psi In distribution
92031202 Length 20 in In distribution
92051302 Length 30 in In distribution
91051103 Length 10 in In distribution
81011602 FALSE 50 In distribution
81051602 FALSE 100 In distribution
80703062 FALSE 100 In distribution
DYNJNVFD72 In distribution
91001603 Length 60 in In distribution
81021482 FALSE 100 In distribution
70015420 Pressure 200 psi In distribution
90703122 Length 12 in In distribution
DYNJTBGHP48R In distribution
91051482 Pressure 1200 psi In distribution
81051603 FALSE 100 In distribution
91051302 Pressure 1200 psi In distribution
91021482 Pressure 500 psi In distribution
91051603 Pressure 1200 psi In distribution
81011302 FALSE 100 In distribution
81031102 FALSE 100 In distribution
91011482 Pressure 1000 psi In distribution
81031103 FALSE 100 In distribution
81051482 FALSE 100 In distribution
81051303 FALSE 100 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Performa® Merit Medical Systems, Inc. 1,101
Impress® Merit Medical Systems, Inc. 839
Super Torque Cordis Corp. 611
Soft-Vu AngioDynamics, Inc. 591
Torcon NB Cook Incorporated 463
Mariner AngioDynamics, Inc. 323
INT,SlideCath Shanghai Kindly Medical Instruments Co., Ltd. 264
Infiniti Cordis Corp. 251
Infiniti Cordis US Corp. 241
AngiOptic AngioDynamics, Inc. 227
Tempo Cordis Corp. 217
SiteSeer™ Medtronic, Inc. 204

Showing 12 of 226. All products under Catheter, Intravascular, Diagnostic

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K160660 2017-01-19
K120008 2012-08-17
K965112 1997-10-10

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer