Soldier®
The Soldier Microcatheter is indicated for use in blood vessels of the peripheral vasculature. It is intended to assist delivery of diagnostic and therapeutic agents into a target treatment…
The Soldier Microcatheter is indicated for use in blood vessels of the peripheral vasculature. It is intended to assist delivery of diagnostic and therapeutic agents into a target treatment area.
The FDA summary describes the Soldier as a single-lumen catheter designed to access small, tortuous vasculature. It has a hydrophilic outer coating and a lubricious PTFE-lined inner lumen to facilitate movement of guidewires and other devices.
Listed Item
The Soldier High Flow Microcatheter is a single lumen catheter designed to access small, tortuous vasculature. It is available in a variety of outer and inner diameters. Each configuration has a hydrophilic coating to provide lubricity for navigation of vessels. The inner lumen is lined with lubricious PTFE to facilitate movement of guidewires and other devices. The distal tip of the catheter is radiopaque to aid in visualization under fluoroscopy. is a single lumen catheter designed to access small, tortuous vasculature. It is available in a variety of outer and inner diameters. Each configuration has a hydrophilic coating to provide lubricity for navigation of vessels. The inner lumen is lined with lubricious PTFE to facilitate movement of guidewires and other devices. The distal tip of the catheter is radiopaque to aid in visualization under fluoroscopy.
Catheter Design
The subject filing identifies the microcatheter as single lumen and describes its distal tip as radiopaque to aid visualization under fluoroscopy.
Who Else Makes It
Concentrated in Jiangsu (5), Guangdong (3), Zhejiang (2). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| GE Medical Systems (China) Co., Ltd. | Wuxi | Jiangsu | Contract manufacturer | 57 |
| Amsino Medical (Kunshan) Co., Ltd. | Kunshan | Jiangsu | Contract manufacturer | 53 |
| Conod Medical Shuyang Co., Ltd. | Shuyang | Jiangsu | Contract manufacturer | 22 |
| Bioxin Medical Co., Ltd. | Weihai | Shandong | Contract manufacturer | 8 |
| GRI Medical & Electronic Technology Co., Ltd. | Jiaxing | Zhejiang | Contract manufacturer | 71 |
| Goals Sterilization Co., Ltd. | Jiaxing | Zhejiang | Contract manufacturer | 26 |
| Wuxi Goals Medical Technology Co., Ltd. | Yixing | Jiangsu | Contract manufacturer | 24 |
| Sunny Medical Device (Shenzhen) Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 11 |
| Curatia Medical Limited | Suzhou | Jiangsu | Specification developer | 5 |
| Shenzhen Vivolight Medical Device&Technology Co., Ltd. | Shenzhen | Guangdong | Manufacturer | 4 |
| Shenzhen Antmed Co., Ltd. | Dongguan | Guangdong | Manufacturer | 4 |
Record
| Listed by | Embolx Inc., United States |
|---|---|
| FDA product code | DQO |
| Device type | Catheter, Intravascular, Diagnostic |
| Device class | Class 2 |
| Regulation | 21 CFR 870.1200 |
| Establishment | Specification developer, Complaint-file establishment, Manufacturer |
| 510(k) | K232536 |
| Record published | 2026-05-20 |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date |
| Sizes | Catheter length 130 to 155 cm; catheter inner diameter 0.022 to 0.027 in |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| S27-SP-155 | Catheter Length 155 cm | In distribution |
| S27-SP-130 | Catheter Length 130 cm | In distribution |
| S22-SP-130 | Catheter Length 130 cm | In distribution |
| S22-SP-155 | Catheter Length 155 cm | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Performa® | Merit Medical Systems, Inc. | 1,101 |
| Impress® | Merit Medical Systems, Inc. | 839 |
| Super Torque | Cordis Corp. | 611 |
| Soft-Vu | AngioDynamics, Inc. | 591 |
| Torcon NB | Cook Incorporated | 463 |
| Mariner | AngioDynamics, Inc. | 323 |
| INT,SlideCath | Shanghai Kindly Medical Instruments Co., Ltd. | 264 |
| Infiniti | Cordis Corp. | 251 |
| Infiniti | Cordis US Corp. | 241 |
| AngiOptic | AngioDynamics, Inc. | 227 |
| Tempo | Cordis Corp. | 217 |
| SiteSeer™ | Medtronic, Inc. | 204 |
Showing 12 of 226. All products under Catheter, Intravascular, Diagnostic
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K232536 | 2024-02-23 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.