Swan-Ganz VIP
Swan-Ganz Thermodilution Venous Infusion Port (VIP) Catheter With Contamination Shield
Who Else Makes It
Concentrated in Jiangsu (5), Guangdong (3), Zhejiang (2). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| GE Medical Systems (China) Co., Ltd. | Wuxi | Jiangsu | Contract manufacturer | 57 |
| Amsino Medical (Kunshan) Co., Ltd. | Kunshan | Jiangsu | Contract manufacturer | 53 |
| Conod Medical Shuyang Co., Ltd. | Shuyang | Jiangsu | Contract manufacturer | 22 |
| Bioxin Medical Co., Ltd. | Weihai | Shandong | Contract manufacturer | 8 |
| GRI Medical & Electronic Technology Co., Ltd. | Jiaxing | Zhejiang | Contract manufacturer | 71 |
| Goals Sterilization Co., Ltd. | Jiaxing | Zhejiang | Contract manufacturer | 26 |
| Wuxi Goals Medical Technology Co., Ltd. | Yixing | Jiangsu | Contract manufacturer | 24 |
| Sunny Medical Device (Shenzhen) Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 11 |
| Curatia Medical Limited | Suzhou | Jiangsu | Specification developer | 5 |
| Shenzhen Vivolight Medical Device&Technology Co., Ltd. | Shenzhen | Guangdong | Manufacturer | 4 |
| Shenzhen Antmed Co., Ltd. | Dongguan | Guangdong | Manufacturer | 4 |
Record
| Listed by | Edwards Lifesciences Technology Sarl, United States |
|---|---|
| FDA product code | DQO |
| Device type | Catheter, Intravascular, Diagnostic |
| Device class | Class 2 |
| Regulation | 21 CFR 870.1200 |
| Establishment | Contract manufacturer, Specification developer, Manufacturer |
| 510(k) | K160084 |
| Record published | 2016-09-03 |
| Record revised | 2023-12-04 (version 6) |
Specifications
| MRI safety | MR Unsafe |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Supplied as a kit | Yes |
| Latex | Contains natural rubber latex |
| Label carries | lot or batch number, expiry date, manufacturing date |
| Storage | Special storage condition: STORE IN A COOL, DRY PLACE |
| Packaging | Pack of 5 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 831VF75P | USABLE LENGTH: 110CM, EXTERIOR DIAMETER: 7.5F (2.5MM), MINIMUM INTRODUCER SIZE: 8.5F (2.8MM), RECOMMENDED GUIDEWIRE SIZE: 0.025 IN (0.64MM) | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Performa® | Merit Medical Systems, Inc. | 1,101 |
| Impress® | Merit Medical Systems, Inc. | 839 |
| Super Torque | Cordis Corp. | 611 |
| Soft-Vu | AngioDynamics, Inc. | 591 |
| Torcon NB | Cook Incorporated | 463 |
| Mariner | AngioDynamics, Inc. | 323 |
| INT,SlideCath | Shanghai Kindly Medical Instruments Co., Ltd. | 264 |
| Infiniti | Cordis Corp. | 251 |
| Infiniti | Cordis US Corp. | 241 |
| AngiOptic | AngioDynamics, Inc. | 227 |
| Tempo | Cordis Corp. | 217 |
| SiteSeer™ | Medtronic, Inc. | 204 |
Showing 12 of 226. All products under Catheter, Intravascular, Diagnostic
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K110103 | 2011-02-11 |
| K014054 | 2002-03-08 |
Recalls Naming This Product
4 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Edwards Lifesciences Technology Sarl | 510(k) number | 2018-12-21 | Class I | Nonconforming Material/Component | These Swan Ganz catheters have incorrect lumen assembly, which causes reversal of the lumens. If the lumens are reversed the clinician may note reverse PA and CVP pressure values and waveforms. | 277 units | 2023-11-02 |
| Edwards Lifesciences Technology Sarl | 510(k) number | 2018-12-21 | Class I | Nonconforming Material/Component | These Swan Ganz catheters have incorrect lumen assembly, which causes reversal of the lumens. If the lumens are reversed the clinician may note reverse PA and CVP pressure values and waveforms. | 875 units | 2023-11-02 |
| Edwards Lifesciences Technology Sarl | 510(k) number | 2018-12-21 | Class I | Nonconforming Material/Component | These Swan Ganz catheters have incorrect lumen assembly, which causes reversal of the lumens. If the lumens are reversed the clinician may note reverse PA and CVP pressure values and waveforms. | 9 units | 2023-11-02 |
| Edwards Lifesciences Technology Sarl | 510(k) number | 2018-12-21 | Class I | Nonconforming Material/Component | These Swan Ganz catheters have incorrect lumen assembly, which causes reversal of the lumens. If the lumens are reversed the clinician may note reverse PA and CVP pressure values and waveforms. | 459 units | 2023-11-02 |
Recalls
2 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2012-05-11 | Class II | Process control | The device is being recalled because the firm received multiple complaints related to passage of a J-tip guidewire when inserted through the distal lumen hub of the catheter. | 32,145 units for all products in Recall Event | 2014-06-17 |
| 2012-05-11 | Class II | Process control | The device is being recalled because the firm received multiple complaints related to passage of a J-tip guidewire when inserted through the distal lumen hub of the catheter. | 32,145 units for all products in Recall Event | 2014-06-17 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.