Sherpa NX Active
Catheter SA5JL60 SA 5F JL6.0 100CM JL60
Who Else Makes It
Concentrated in Shanghai (5), Jiangsu (5), Guangdong (3). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Jabil Circuit (Shanghai) Ltd. | Shanghai | Shanghai | Contract manufacturer | 31 |
| Covidien Medical Products (Shanghai) Manufacturing LLC | Shanghai | Shanghai | Contract manufacturer | 8 |
| Sterigenics Shanghai ETO Ltd. | Shanghai | Shanghai | Contract manufacturer | 65 |
| Steris Sterilization Technologies (Suzhou) Ltd | Suzhou | Jiangsu | Contract manufacturer | 44 |
| Goals Sterilization Co., Ltd. | Jiaxing | Zhejiang | Contract manufacturer | 26 |
| Wuxi Goals Medical Technology Co., Ltd. | Yixing | Jiangsu | Contract manufacturer | 24 |
| Suzhou Zenith Vascular Scitech Limited | Suzhou | Jiangsu | Manufacturer | 6 |
| Haolang Technology (Foshan) Limited Corporation | Foshan | Guangdong | Contract manufacturer | 6 |
| OrbusNeich Medical (Shenzhen) Co., Ltd. | Shenzhen | Guangdong | Complaint-file establishment | 5 |
| Curatia Medical Limited | Suzhou | Jiangsu | Specification developer | 5 |
| Shanghai Wallaby Medical Technologies Co., Inc. | Shanghai | Shanghai | Contract manufacturer | 5 |
| DK Medical Technology Co., Ltd. | Suzhou | Jiangsu | Manufacturer | 3 |
Showing 12 of 14. All 14 manufacturers in China registered for Catheter, Percutaneous
Record
| Listed by | Medtronic, Inc., United States |
|---|---|
| FDA product code | DQY |
| Device type | Catheter, Percutaneous |
| Device class | Class 2 |
| Regulation | 21 CFR 870.1250 |
| Establishment | Specification developer, Repacker / relabeller, Manufacturer, Exporter |
| 510(k) | K042489 |
| Record published | 2016-05-30 |
| Record revised | 2022-09-05 (version 10) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number |
| Storage | Special storage condition: Store catheters straight in a cool dark area. Do not expose catheters to solvents or ionizing radiation. |
| Packaging | Pack of 5 |
| Sizes | Length 45 to 110 cm; catheter gauge 5 to 6 Fr |
| Distribution end date | 2020-06-24 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| SA6SAL10 | Curve SAL1.0 | In distribution |
| SA6EBU375SH | Length 100.0 cm | In distribution |
| SA5JL45 | Length 100.0 cm | In distribution |
| SA6EBU375 | Length 100.0 cm | In distribution |
| SA6HSISH | Length 100.0 cm | In distribution |
| SA6SAL20SH | Length 100.0 cm | In distribution |
| SA6JR35 | Length 100.0 cm | In distribution |
| SA6RBU35 | Catheter Gauge 6.0 Fr | In distribution |
| SA6EBU45SH | Curve EBU4.5 SH | In distribution |
| SA6JR40 | Catheter Gauge 6.0 Fr | In distribution |
| SA6EBU30 | Catheter Gauge 6.0 Fr | In distribution |
| SA6JL40 | Catheter Gauge 6.0 Fr | In distribution |
| SA6SL50SH | Catheter Gauge 6.0 Fr | In distribution |
| SA6JCL50 | Curve JCL5.0 | In distribution |
| SA6HSI | Length 100.0 cm | Withdrawn |
| SA6FL40G | Curve FL4.0G | Withdrawn |
| SA6SAL15 | Curve SAL1.5 | Withdrawn |
| SA5MODHSII | Catheter Gauge 5.0 Fr | Withdrawn |
| SA5FL60 | Length 100.0 cm | Withdrawn |
| SA5SL40 | Length 100.0 cm | Withdrawn |
| SA5SL35 | Curve SL3.5 | Withdrawn |
| SA6LCBSH | Curve LCB SH | Withdrawn |
| SA5JL60 | Curve JL6.0 | Withdrawn |
| SA6IMAK | Curve IMA | Withdrawn |
| SA6ARA7515 | Length 100.0 cm | Withdrawn |
| SA6JR40 | Curve JR4.0 | Withdrawn |
| SA6AR20 | Length 100.0 cm | Withdrawn |
| SA5FR30 | Length 100.0 cm | Withdrawn |
| SA6AR10 | Length 100.0 cm | Withdrawn |
| SA5JCR35 | Catheter Gauge 5.0 Fr | Withdrawn |
| SA6EBU35A | Length 110.0 cm | Withdrawn |
| SA5ERADL | Catheter Gauge 5.0 Fr | Withdrawn |
| SA6JCL50 | Catheter Gauge 6.0 Fr | Withdrawn |
| SA5VDL1 | Length 100.0 cm | Withdrawn |
| SA6CHAMP40 | Length 100.0 cm | Withdrawn |
| SA6VDL13 | Catheter Gauge 6.0 Fr | Withdrawn |
| SA6JR40K | Length 55.0 cm | Withdrawn |
| SA5AL75 | Curve AL.75 | Withdrawn |
| SA6RDCV | Catheter Gauge 6.0 Fr | Withdrawn |
| SA6JL40PSH | Curve JL4.0P SH | Withdrawn |
| SA6FR35 | Curve FR3.5 | Withdrawn |
| SA6ERADLSH | Catheter Gauge 6.0 Fr | Withdrawn |
| SA6EBU40SHD | Length 90.0 cm | Withdrawn |
| SA5AR105 | Curve AR1.0 | Withdrawn |
| SA6RCBII | Catheter Gauge 6.0 Fr | Withdrawn |
| SA6LCB | Catheter Gauge 6.0 Fr | Withdrawn |
| SA63DRIGHT | Catheter Gauge 6.0 Fr | Withdrawn |
| SA6MAC3030SH | Catheter Gauge 6.0 Fr | Withdrawn |
| SA5EBU50 | Catheter Gauge 5.0 Fr | Withdrawn |
| SA5FL40 | Catheter Gauge 5.0 Fr | Withdrawn |
| SA5JL50A | Catheter Gauge 5.0 Fr | Withdrawn |
| SA6AR205 | Length 100.0 cm | Withdrawn |
| SA6JR40SHD | Catheter Gauge 6.0 Fr | Withdrawn |
| SA5JR50 | Catheter Gauge 5.0 Fr | Withdrawn |
| SA5HSII | Catheter Gauge 5.0 Fr | Withdrawn |
| SA5SCR50 | Length 100.0 cm | Withdrawn |
| SA5JR50A | Catheter Gauge 5.0 Fr | Withdrawn |
| SA5RLTJR40 | Length 100.0 cm | Withdrawn |
| SA6CHAMP30SH | Length 100.0 cm | Withdrawn |
| SA53DRIGHT | Curve 3D RIGHT | Withdrawn |
| SA6MAC30SH | Catheter Gauge 6.0 Fr | Withdrawn |
| SA6HSIIISH | Catheter Gauge 6.0 Fr | Withdrawn |
| SA6AL20 | Catheter Gauge 6.0 Fr | Withdrawn |
| SA6AL75 | Curve AL.75 | Withdrawn |
| SA5JR35 | Curve JR3.5 | Withdrawn |
| SA6JR35 | Length 100.0 cm | Withdrawn |
| SA6RBU40 | Catheter Gauge 6.0 Fr | Withdrawn |
| SA5CHAMP05 | Catheter Gauge 5.0 Fr | Withdrawn |
| SA6EBU35SH | Catheter Gauge 6.0 Fr | Withdrawn |
| SA6RBU35SH | Length 100.0 cm | Withdrawn |
| SA6HSIISH | Curve HSII SH | Withdrawn |
| SA6AR20 | Catheter Gauge 6.0 Fr | Withdrawn |
| SA6JL45 | Catheter Gauge 6.0 Fr | Withdrawn |
| SA5MAC375 | Curve MAC3.75 | Withdrawn |
| SA6JL30SH | Catheter Gauge 6.0 Fr | Withdrawn |
| SA6AL30A | Length 110.0 cm | Withdrawn |
| SA6JCL35SH | Length 100.0 cm | Withdrawn |
| SA6MP2 | Curve MP2 | Withdrawn |
| SA5MAC30 | Catheter Gauge 5.0 Fr | Withdrawn |
| SA6JL50 | Curve JL5.0 | Withdrawn |
| SA5JR35 | Curve JR3.5 | Withdrawn |
| SA6SAL15SH | Length 100.0 cm | Withdrawn |
| SA5SR60 | Length 100.0 cm | Withdrawn |
| SA6RBU35 | Curve RBU3.5 | Withdrawn |
| SA6ERADL | Length 100.0 cm | Withdrawn |
| SA6HSIISH | Length 100.0 cm | Withdrawn |
| SA5JR40 | Curve JR4.0 | Withdrawn |
| SA6MAC50 | Catheter Gauge 6.0 Fr | Withdrawn |
| SA6SR50 | Length 100.0 cm | Withdrawn |
| SA6CHAMP30 | Catheter Gauge 6.0 Fr | Withdrawn |
| SA6CHAMP25SH | Length 100.0 cm | Withdrawn |
| SA5AR10 | Catheter Gauge 5.0 Fr | Withdrawn |
| SA6EBU40 | Length 100.0 cm | Withdrawn |
| SA6IMAV | Length 45.0 cm | Withdrawn |
| SA5AR20 | Catheter Gauge 5.0 Fr | Withdrawn |
| SA6JCL45 | Length 100.0 cm | Withdrawn |
| SA5MAC45 | Curve MAC4.5 | Withdrawn |
| SA6AL205 | Catheter Gauge 6.0 Fr | Withdrawn |
| SA6ERADRST | Catheter Gauge 6.0 Fr | Withdrawn |
| SA6EBUL30 | Catheter Gauge 6.0 Fr | Withdrawn |
| SA5RAD1 | Catheter Gauge 5.0 Fr | Withdrawn |
| SA5FR45 | Catheter Gauge 5.0 Fr | Withdrawn |
| SA5AL10 | Length 100.0 cm | Withdrawn |
| SA6SAL25SH | Length 100.0 cm | Withdrawn |
| SA5SAR20 | Curve SAR2.0 | Withdrawn |
| SA6RDCK | Catheter Gauge 6.0 Fr | Withdrawn |
| SA6JR405 | Catheter Gauge 6.0 Fr | Withdrawn |
| SA6MRESS | Length 100.0 cm | Withdrawn |
| SA5JR40A | Length 110.0 cm | Withdrawn |
| SA5JCL40 | Catheter Gauge 5.0 Fr | Withdrawn |
| SA63DMIGISH | Curve 3D MIGI SH | Withdrawn |
| SA6JL50A | Length 110.0 cm | Withdrawn |
| SA5RCB | Curve RCB | Withdrawn |
| SA5SCR35 | Catheter Gauge 5.0 Fr | Withdrawn |
| SA5JCL30 | Catheter Gauge 5.0 Fr | Withdrawn |
| SA5MB1 | Catheter Gauge 5.0 Fr | Withdrawn |
| SA6EBU355 | Length 100.0 cm | Withdrawn |
| SA6ALR12 | Catheter Gauge 6.0 Fr | Withdrawn |
| SA6MAC2520 | Curve MAC2.5 20° | Withdrawn |
| SA5IMAJ | Length 60.0 cm | Withdrawn |
| SA6JL40SHA | Catheter Gauge 6.0 Fr | Withdrawn |
| SA6JL40SH | Curve JL4.0 SH | Withdrawn |
| SA6ELGAMAL | Curve EL GAMAL | Withdrawn |
| SA5IMAA | Catheter Gauge 5.0 Fr | Withdrawn |
| SA6EBU455 | Curve EBU4.5 | Withdrawn |
| SA6SR45 | Length 100.0 cm | Withdrawn |
| SA6SCR40 | Catheter Gauge 6.0 Fr | Withdrawn |
| SA6SAL20 | Length 100.0 cm | Withdrawn |
| SA6IMASH | Length 100.0 cm | Withdrawn |
| SA5SL60 | Length 100.0 cm | Withdrawn |
| SA5ERADLLT | Length 100.0 cm | Withdrawn |
| SA6SL30 | Curve SL3.0 | Withdrawn |
| SA5MPST | Length 100.0 cm | Withdrawn |
| SA5RRAD | Curve RRAD | Withdrawn |
| SA6JR40A | Catheter Gauge 6.0 Fr | Withdrawn |
| SA6ECR35 | Length 100.0 cm | Withdrawn |
| SA5LARA | Curve LARA | Withdrawn |
| SA6HSII | Catheter Gauge 6.0 Fr | Withdrawn |
| SA6ECR30 | Catheter Gauge 6.0 Fr | Withdrawn |
| SA6JR35SHD | Length 90.0 cm | Withdrawn |
| SA5SAL10 | Length 100.0 cm | Withdrawn |
| SA6RDND1K | Curve RDND1 | Withdrawn |
| SA6SL60SH | Catheter Gauge 6.0 Fr | Withdrawn |
| SA5JR355 | Curve JR3.5 | Withdrawn |
| SA6AL15 | Curve AL1.5 | Withdrawn |
| SA6HSIV | Curve HSI | Withdrawn |
| SA6SCR35 | Catheter Gauge 6.0 Fr | Withdrawn |
| SA6MAC40 | Curve MAC4.0 | Withdrawn |
| SA6CHAMP20 | Catheter Gauge 6.0 Fr | Withdrawn |
| SA6FR40 | Curve FR4.0 | Withdrawn |
| SA6SCR40SH | Length 100.0 cm | Withdrawn |
| SA5EBU375 | Catheter Gauge 5.0 Fr | Withdrawn |
| SA6SAL10 | Length 100.0 cm | Withdrawn |
| SA5PAPA1 | Curve PAPA1 | Withdrawn |
| SA6JR45 | Catheter Gauge 6.0 Fr | Withdrawn |
| SA6HUG3045 | Catheter Gauge 6.0 Fr | Withdrawn |
| SA6MB2SH | Length 100.0 cm | Withdrawn |
| SA6FL40GSH | Curve FL4.0G SH | Withdrawn |
| SA5JL40 | Curve JL4.0 | Withdrawn |
| SA6CHAMP20SH | Length 100.0 cm | Withdrawn |
| SA6JCR35 | Curve JCR3.5 | Withdrawn |
| SA6AL30 | Curve AL3.0 | Withdrawn |
| SA6MPHK | Length 55.0 cm | Withdrawn |
| SA5RBU35 | Length 100.0 cm | Withdrawn |
| SA5CHAMP30 | Length 100.0 cm | Withdrawn |
| SA6JR35D | Curve JR3.5 | Withdrawn |
| SA6FR40SH | Length 100.0 cm | Withdrawn |
| SA6EBUL375 | Length 100.0 cm | Withdrawn |
| SA6MPST | Catheter Gauge 6.0 Fr | Withdrawn |
| SA63DRCSH | Curve 3DRC SH | Withdrawn |
| SA6JL50SH | Length 100.0 cm | Withdrawn |
| SA6JL40MOD | Catheter Gauge 6.0 Fr | Withdrawn |
| SA5EBU20 | Catheter Gauge 5.0 Fr | Withdrawn |
| SA6RBU45 | Length 100.0 cm | Withdrawn |
| SA63DRC | Catheter Gauge 6.0 Fr | Withdrawn |
| SA6ERADLSTSH | Curve ERAD LEFT SHORT TIP SH | Withdrawn |
| SA6AR10A | Length 110.0 cm | Withdrawn |
| SA6JR40MOD | Length 100.0 cm | Withdrawn |
| SA6NOTOSH | Curve NOTO SH | Withdrawn |
| SA6ELGAMALSH | Length 100.0 cm | Withdrawn |
| SA6RBU40SH | Catheter Gauge 6.0 Fr | Withdrawn |
| SA6JL30 | Catheter Gauge 6.0 Fr | Withdrawn |
| SA6ALR12SH | Curve ALR1-2 SH | Withdrawn |
| SA5MAC35 | Curve MAC3.5 | Withdrawn |
| SA6SAL20 | Catheter Gauge 6.0 Fr | Withdrawn |
| SA6JR50 | Catheter Gauge 6.0 Fr | Withdrawn |
| SA5ELGAMAL | Curve EL GAMAL | Withdrawn |
| SA5JCR40 | Length 100.0 cm | Withdrawn |
| SA6AL20A | Curve AL2.0 | Withdrawn |
| SA6EBU45SH | Length 100.0 cm | Withdrawn |
| SA6LARA | Catheter Gauge 6.0 Fr | Withdrawn |
| SA6JL35 | Catheter Gauge 6.0 Fr | Withdrawn |
| SA6RBU40V | Curve RBU4.0 | Withdrawn |
| SA5SAL20 | Curve SAL2.0 | Withdrawn |
| SA6ARA9015SH | Catheter Gauge 6.0 Fr | Withdrawn |
| SA5AR20 | Curve AR2.0 | Withdrawn |
| SA5AR205 | Catheter Gauge 5.0 Fr | Withdrawn |
| SA6FL40 | Catheter Gauge 6.0 Fr | Withdrawn |
| SA6EBU375SH | Catheter Gauge 6.0 Fr | Withdrawn |
| SA6MAC35 | Length 100.0 cm | Withdrawn |
| SA6ARA7526 | Catheter Gauge 6.0 Fr | Withdrawn |
| SA6JL405 | Catheter Gauge 6.0 Fr | Withdrawn |
| SA6LCBSHD | Curve LCB SH | Withdrawn |
| SA6IMASHD | Length 90.0 cm | Withdrawn |
| SA63DRIGHTSH | Length 100.0 cm | Withdrawn |
| SA5JCL35 | Length 100.0 cm | Withdrawn |
| SA6AL25SH | Catheter Gauge 6.0 Fr | Withdrawn |
| SA6EBU30 | Catheter Gauge 6.0 Fr | Withdrawn |
| SA5RAD2 | Curve RAD2 | Withdrawn |
| SA5MB2 | Length 100.0 cm | Withdrawn |
| SA6JL45 | Length 100.0 cm | Withdrawn |
| SA5NOTO | Catheter Gauge 5.0 Fr | Withdrawn |
| SA6EBUL30SH | Length 100.0 cm | Withdrawn |
| SA5MRADIAL | Catheter Gauge 5.0 Fr | Withdrawn |
| SA6MP1SH | Curve MP1 SH | Withdrawn |
| SA6SR40SH | Length 100.0 cm | Withdrawn |
| SA6FL40 | Catheter Gauge 6.0 Fr | Withdrawn |
| SA6MAC45 | Curve MAC4.5 | Withdrawn |
| SA63DRIGHT | Curve 3DRIGHT | Withdrawn |
| SA6AL15SH | Curve AL1.5 SH | Withdrawn |
| SA6EBU45 | Catheter Gauge 6.0 Fr | Withdrawn |
| SA5MRESS | Curve MRESS | Withdrawn |
| SA6JR35A | Length 110.0 cm | Withdrawn |
| SA6HSIII | Length 100.0 cm | Withdrawn |
| SA5PAPA | Length 100.0 cm | Withdrawn |
| SA6AL75A | Catheter Gauge 6.0 Fr | Withdrawn |
| SA5RCBD | Curve RCB | Withdrawn |
| SA6LCBSH | Catheter Gauge 6.0 Fr | Withdrawn |
| SA5RBU40 | Length 100.0 cm | Withdrawn |
| SA6JL355 | Catheter Gauge 6.0 Fr | Withdrawn |
| SA6SL40SH | Catheter Gauge 6.0 Fr | Withdrawn |
| SA6SL35 | Catheter Gauge 6.0 Fr | Withdrawn |
| SA6EBU35 | Catheter Gauge 6.0 Fr | Withdrawn |
| SA6MAC35 | Curve MAC3.5 | Withdrawn |
| SA6JCL45SH | Catheter Gauge 6.0 Fr | Withdrawn |
| SA6SCR40K | Catheter Gauge 6.0 Fr | Withdrawn |
| SA6JCL40 | Catheter Gauge 6.0 Fr | Withdrawn |
| SA6CHAMP20K | Catheter Gauge 6.0 Fr | Withdrawn |
| SA5SR30 | Curve SR3.0 | Withdrawn |
| SA6AR20SH | Length 100.0 cm | Withdrawn |
| SA6SAL10SH | Curve SAL1.0 SH | Withdrawn |
| SA6SL30SH | Length 100.0 cm | Withdrawn |
| SA5SAL15 | Length 100.0 cm | Withdrawn |
| SA6JR40SHA | Length 110.0 cm | Withdrawn |
| SA6SR50 | Catheter Gauge 6.0 Fr | Withdrawn |
| SA6IMAK | Catheter Gauge 6.0 Fr | Withdrawn |
| SA6RCB | Curve RCB | Withdrawn |
| SA6SL35SH | Curve SL3.5 SH | Withdrawn |
| SA6SAL40 | Catheter Gauge 6.0 Fr | Withdrawn |
| SA6MAC30 | Curve MAC3.0 | Withdrawn |
Showing 250 of 300 catalogue numbers.
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Launcher™ | Medtronic, Inc. | 3,805 |
| Sherpa NX Balanced™ | Medtronic, Inc. | 1,523 |
| Arrow | Teleflex Medical LLC | 1,249 |
| Z2 | Medtronic, Inc. | 955 |
| Vista Brite TIP | Cordis Corp. | 789 |
| Mach1™ | Boston Scientific Corporation | 777 |
| Zuma® | Medtronic, Inc. | 569 |
| Convey | Pendracare International B.V. | 532 |
| Taiga | Medtronic, Inc. | 307 |
| RunWay™ | Boston Scientific Corporation | 300 |
| ConcierGE Guiding Excellence™ | Merit Medical Systems, Inc. | 295 |
| Wiseguide™ | Boston Scientific Corporation | 277 |
Showing 12 of 500. All products under Catheter, Percutaneous
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K253409 | 2025-12-19 |
| K250558 | 2025-03-27 |
| K223178 | 2022-11-08 |
| K222873 | 2022-11-07 |
| K192712 | 2020-08-03 |
| K183353 | 2019-03-22 |
| K183493 | 2019-03-15 |
| K132673 | 2013-10-22 |
| K121219 | 2012-09-25 |
| K112917 | 2011-10-27 |
| K103386 | 2011-02-11 |
| K101885 | 2010-09-09 |
| K090659 | 2009-03-26 |
| K080428 | 2008-12-09 |
| K082670 | 2008-12-04 |
Recalls Naming This Product
191 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Medtronic Vascular | 510(k) number | 2019-03-15 | Class I | Component design/selection | There is a potential for extensive loss of primary segment material exposing underlying stainless-steel braid wires on a subset of 6F Sherpa catheters. | 1226 units | 2024-04-26 |
| Medtronic Vascular | 510(k) number | 2019-03-15 | Class I | Component design/selection | There is a potential for extensive loss of primary segment material exposing underlying stainless-steel braid wires on a subset of 6F Sherpa catheters. | 658 units | 2024-04-26 |
| Medtronic Vascular | 510(k) number | 2019-03-15 | Class I | Component design/selection | There is a potential for extensive loss of primary segment material exposing underlying stainless-steel braid wires on a subset of 6F Sherpa catheters. | 538 units | 2024-04-26 |
| Medtronic Vascular | 510(k) number | 2019-03-15 | Class I | Component design/selection | There is a potential for extensive loss of primary segment material exposing underlying stainless-steel braid wires on a subset of 6F Sherpa catheters. | 12 units | 2024-04-26 |
| Medtronic Vascular | 510(k) number | 2019-03-15 | Class I | Component design/selection | There is a potential for extensive loss of primary segment material exposing underlying stainless-steel braid wires on a subset of 6F Sherpa catheters. | 4 units | 2024-04-26 |
| Medtronic Vascular | 510(k) number | 2019-03-15 | Class I | Component design/selection | There is a potential for extensive loss of primary segment material exposing underlying stainless-steel braid wires on a subset of 6F Sherpa catheters. | 1 unit | 2024-04-26 |
| Medtronic Vascular | 510(k) number | 2019-03-15 | Class I | Component design/selection | There is a potential for extensive loss of primary segment material exposing underlying stainless-steel braid wires on a subset of 6F Sherpa catheters. | 12 units | 2024-04-26 |
| Medtronic Vascular | 510(k) number | 2019-03-15 | Class I | Component design/selection | There is a potential for extensive loss of primary segment material exposing underlying stainless-steel braid wires on a subset of 6F Sherpa catheters. | 1491 units | 2024-04-26 |
| Medtronic Vascular | 510(k) number | 2019-03-15 | Class I | Component design/selection | There is a potential for extensive loss of primary segment material exposing underlying stainless-steel braid wires on a subset of 6F Sherpa catheters. | 655 units | 2024-04-26 |
| Medtronic Vascular | 510(k) number | 2019-03-15 | Class I | Component design/selection | There is a potential for extensive loss of primary segment material exposing underlying stainless-steel braid wires on a subset of 6F Sherpa catheters. | 1701 units | 2024-04-26 |
| Medtronic Vascular | 510(k) number | 2019-03-15 | Class I | Component design/selection | There is a potential for extensive loss of primary segment material exposing underlying stainless-steel braid wires on a subset of 6F Sherpa catheters. | 221 units | 2024-04-26 |
| Medtronic Vascular | 510(k) number | 2019-03-15 | Class I | Component design/selection | There is a potential for extensive loss of primary segment material exposing underlying stainless-steel braid wires on a subset of 6F Sherpa catheters. | 29 units | 2024-04-26 |
| Medtronic Vascular | 510(k) number | 2019-03-15 | Class I | Component design/selection | There is a potential for extensive loss of primary segment material exposing underlying stainless-steel braid wires on a subset of 6F Sherpa catheters. | 6 units | 2024-04-26 |
| Medtronic Vascular | 510(k) number | 2019-03-15 | Class I | Component design/selection | There is a potential for extensive loss of primary segment material exposing underlying stainless-steel braid wires on a subset of 6F Sherpa catheters. | 5 units | 2024-04-26 |
| Medtronic Vascular | 510(k) number | 2019-03-15 | Class I | Component design/selection | There is a potential for extensive loss of primary segment material exposing underlying stainless-steel braid wires on a subset of 6F Sherpa catheters. | 18 units | 2024-04-26 |
| Medtronic Vascular | 510(k) number | 2019-03-15 | Class I | Component design/selection | There is a potential for extensive loss of primary segment material exposing underlying stainless-steel braid wires on a subset of 6F Sherpa catheters. | 2 units | 2024-04-26 |
| Medtronic Vascular | 510(k) number | 2019-03-15 | Class I | Component design/selection | There is a potential for extensive loss of primary segment material exposing underlying stainless-steel braid wires on a subset of 6F Sherpa catheters. | 17 units | 2024-04-26 |
| Medtronic Vascular | 510(k) number | 2019-03-15 | Class I | Component design/selection | There is a potential for extensive loss of primary segment material exposing underlying stainless-steel braid wires on a subset of 6F Sherpa catheters. | 20 units | 2024-04-26 |
| Medtronic Vascular | 510(k) number | 2019-03-15 | Class I | Component design/selection | There is a potential for extensive loss of primary segment material exposing underlying stainless-steel braid wires on a subset of 6F Sherpa catheters. | 9 units | 2024-04-26 |
| Medtronic Vascular | 510(k) number | 2019-03-15 | Class I | Component design/selection | There is a potential for extensive loss of primary segment material exposing underlying stainless-steel braid wires on a subset of 6F Sherpa catheters. | 215 units | 2024-04-26 |
| Medtronic Vascular | 510(k) number | 2019-03-15 | Class I | Component design/selection | There is a potential for extensive loss of primary segment material exposing underlying stainless-steel braid wires on a subset of 6F Sherpa catheters. | 14 units | 2024-04-26 |
| Medtronic Vascular | 510(k) number | 2019-03-15 | Class I | Component design/selection | There is a potential for extensive loss of primary segment material exposing underlying stainless-steel braid wires on a subset of 6F Sherpa catheters. | 555 units | 2024-04-26 |
| Medtronic Vascular | 510(k) number | 2019-03-15 | Class I | Component design/selection | There is a potential for extensive loss of primary segment material exposing underlying stainless-steel braid wires on a subset of 6F Sherpa catheters. | 53 units | 2024-04-26 |
| Medtronic Vascular | 510(k) number | 2019-03-15 | Class I | Component design/selection | There is a potential for extensive loss of primary segment material exposing underlying stainless-steel braid wires on a subset of 6F Sherpa catheters. | 42 units | 2024-04-26 |
| Medtronic Vascular | 510(k) number | 2019-03-15 | Class I | Component design/selection | There is a potential for extensive loss of primary segment material exposing underlying stainless-steel braid wires on a subset of 6F Sherpa catheters. | 2 units | 2024-04-26 |
| Medtronic Vascular | 510(k) number | 2019-03-15 | Class I | Component design/selection | There is a potential for extensive loss of primary segment material exposing underlying stainless-steel braid wires on a subset of 6F Sherpa catheters. | 27 units | 2024-04-26 |
| Medtronic Vascular | 510(k) number | 2019-03-15 | Class I | Component design/selection | There is a potential for extensive loss of primary segment material exposing underlying stainless-steel braid wires on a subset of 6F Sherpa catheters. | 12 units | 2024-04-26 |
| Medtronic Vascular | 510(k) number | 2019-03-15 | Class I | Component design/selection | There is a potential for extensive loss of primary segment material exposing underlying stainless-steel braid wires on a subset of 6F Sherpa catheters. | 22 units | 2024-04-26 |
| Medtronic Vascular | 510(k) number | 2019-03-15 | Class I | Component design/selection | There is a potential for extensive loss of primary segment material exposing underlying stainless-steel braid wires on a subset of 6F Sherpa catheters. | 14 units | 2024-04-26 |
| Medtronic Vascular | 510(k) number | 2019-03-15 | Class I | Component design/selection | There is a potential for extensive loss of primary segment material exposing underlying stainless-steel braid wires on a subset of 6F Sherpa catheters. | 12 units | 2024-04-26 |
| Medtronic Vascular | 510(k) number | 2019-03-15 | Class I | Component design/selection | There is a potential for extensive loss of primary segment material exposing underlying stainless-steel braid wires on a subset of 6F Sherpa catheters. | 10 units | 2024-04-26 |
| Medtronic Vascular | 510(k) number | 2019-03-15 | Class I | Component design/selection | There is a potential for extensive loss of primary segment material exposing underlying stainless-steel braid wires on a subset of 6F Sherpa catheters. | 5 units | 2024-04-26 |
| Medtronic Vascular | 510(k) number | 2019-03-15 | Class I | Component design/selection | There is a potential for extensive loss of primary segment material exposing underlying stainless-steel braid wires on a subset of 6F Sherpa catheters. | 39 units | 2024-04-26 |
| Medtronic Vascular | 510(k) number | 2019-03-15 | Class I | Component design/selection | There is a potential for extensive loss of primary segment material exposing underlying stainless-steel braid wires on a subset of 6F Sherpa catheters. | 2 units | 2024-04-26 |
| Medtronic Vascular | 510(k) number | 2019-03-15 | Class I | Component design/selection | There is a potential for extensive loss of primary segment material exposing underlying stainless-steel braid wires on a subset of 6F Sherpa catheters. | 6 units | 2024-04-26 |
| Medtronic Vascular | 510(k) number | 2019-03-15 | Class I | Component design/selection | There is a potential for extensive loss of primary segment material exposing underlying stainless-steel braid wires on a subset of 6F Sherpa catheters. | 0 units | 2024-04-26 |
| Medtronic Vascular | 510(k) number | 2019-03-15 | Class I | Component design/selection | There is a potential for extensive loss of primary segment material exposing underlying stainless-steel braid wires on a subset of 6F Sherpa catheters. | 8 units | 2024-04-26 |
| Medtronic Vascular | 510(k) number | 2019-03-15 | Class I | Component design/selection | There is a potential for extensive loss of primary segment material exposing underlying stainless-steel braid wires on a subset of 6F Sherpa catheters. | 20 units | 2024-04-26 |
| Medtronic Vascular | 510(k) number | 2019-03-15 | Class I | Component design/selection | There is a potential for extensive loss of primary segment material exposing underlying stainless-steel braid wires on a subset of 6F Sherpa catheters. | 4 units | 2024-04-26 |
| Medtronic Vascular | 510(k) number | 2019-03-15 | Class I | Component design/selection | There is a potential for extensive loss of primary segment material exposing underlying stainless-steel braid wires on a subset of 6F Sherpa catheters. | 10 units | 2024-04-26 |
Showing 40 of 191.
Recalls
1 of these is Class I. Class I is the FDA’s most serious grade: a reasonable probability of serious injury or death. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2022-04-20 | Class II | Under Investigation by firm | The firm’s internal processes identified that certain lots may have an improperly sealed barrier that could potentially compromise sterility. | 1385 devices | |
| 2021-09-09 | Class II | Under Investigation by firm | Medtronic is recalling three lots of unused C315HIS Delivery Catheters due to reports of an inability to pass a lead through the catheter. | 591 units | |
| 2017-09-26 | Class I | Nonconforming Material/Component | Complaints regarding 6F Taiga guide catheter tip detachment and/or tip splitting. | 15,923 | 2021-04-27 |
| 2013-06-12 | Class II | Labeling mix-ups | Medtronic has identified a labeling issue for 24 units of the Launcher coronary Guide Catheter. The two affected catheter lots are mislabeled and do not accurately reflect the catheters contained within each package. | 15 | 2013-11-19 |
| 2008-08-27 | Not classified | Process control | Medtronic has identified an issue with the packaging for specific lots of the Medtronic Adjustable Valve and valves contained in the Attain Left Heart Delivery System kits. A small number of valve package seals could be compromised. | 35,193 total | 2011-05-07 |
| 2008-08-27 | Not classified | Process control | Medtronic has identified an issue with the packaging for specific lots of the Medtronic Adjustable Valve and valves contained in the Attain Left Heart Delivery System kits. A small number of valve package seals could be compromised. | 35,193 total | 2011-05-07 |
| 2002-11-25 | Not classified | Other | An RF pulse occurs each time the temperature set point increase button is activated while ablating and this can result in heart rhythm disturbances. | 775 units | 2003-11-04 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.