Mini Stick MAX

Mini Stick MAX Coaxial Microintroducer Kit

Registry build 21.09.26
1manufacturer
28catalogue numbers in this listing
16recalls on this code

Who Else Makes It

Registered in Guangdong.

Chinese manufacturers registered for FDA product code DRE
Manufacturer City Province Registered as Device types
Lifetech Scientific (Shenzhen) Co,.ltd Shenzhen Guangdong Manufacturer 3

Record

Regulatory record for Mini Stick MAX
Listed by AngioDynamics, Inc., United States
FDA product code DRE
Device type Dilator, Vessel, For Percutaneous Catheterization
Device class Class 2
Regulation 21 CFR 870.1310
Establishment Contract manufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer
510(k) K132713
Record published 2024-10-18
Record revised 2025-02-06 (version 3)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date
Packaging Box of 10
Sizes Catheter gauge 4 to 5 Fr; outer diameter 1.42 to 1.73 mm; length 10 cm; lumen/inner diameter 0.5 mm

Catalogue Numbers

Catalogue numbers for Mini Stick MAX
Catalogue number Size Status
H965457490 Catheter Gauge 4 Fr In distribution
H965457710 Catheter Gauge 4 Fr In distribution
H965457480 Lumen/Inner Diameter 0.5 mm In distribution
H965457510 Length 10 cm In distribution
H965457500 Lumen/Inner Diameter 0.5 mm In distribution
H965457750 Outer Diameter 1.73 mm In distribution
H965457810 Catheter Gauge 4 Fr In distribution
H965457790 Lumen/Inner Diameter 0.5 mm In distribution
H965457850 Lumen/Inner Diameter 0.5 mm In distribution
H965457680 Lumen/Inner Diameter 0.5 mm In distribution
H965457600 Lumen/Inner Diameter 0.5 mm In distribution
H965457580 Outer Diameter 1.42 mm In distribution
H965457720 Lumen/Inner Diameter 0.5 mm In distribution
H965457740 Catheter Gauge 5 Fr In distribution
H965457560 Length 10 cm In distribution
H965457860 Catheter Gauge 5 Fr In distribution
H965457550 Outer Diameter 1.73 mm In distribution
H965457840 Lumen/Inner Diameter 0.5 mm In distribution
H965457820 Length 10 cm In distribution
H965457570 Outer Diameter 1.42 mm In distribution
H965457590 Lumen/Inner Diameter 0.5 mm In distribution
H965457530 Outer Diameter 1.42 mm In distribution
H965457700 Outer Diameter 1.42 mm In distribution
H965457760 Lumen/Inner Diameter 0.5 mm In distribution
H965457540 Outer Diameter 1.73 mm In distribution
H965457520 Lumen/Inner Diameter 0.5 mm In distribution
H965457610 Outer Diameter 1.42 mm In distribution
H965457830 Outer Diameter 1.73 mm In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Prelude® Merit Medical Systems, Inc. 323
Prelude PRO™ Merit Medical Systems, Inc. 132
Cook Cook Incorporated 125
Avanti Cordis Corp. 81
Dilator, Vessel, For Percutaneous Catheterization B. Braun Interventional Systems, Inc. 59
Merit MAK™ Merit Medical Systems, Inc. 49
Prelude ACT™ Merit Medical Systems, Inc. 38
AngioDynamics Navilyst Medical, Inc. 38
Super Sheath Togo Medikit Co., Ltd. 31
Avanti Cordis US Corp. 29
OneStic Micro-Access Introducer Argon Medical Devices, Inc. 27
Medcomp Vessel Dilatormedcomp Vessel Dilator Medical Components Inc 26

Showing 12 of 159. All products under Dilator, Vessel, For Percutaneous Catheterization

Recalls Naming This Product

15 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of Mini Stick MAX
Recalled by Identified by Initiated FDA class Root cause Reason Quantity
AngioDynamics, Inc. 510(k) number 2024-01-30 Class II Process control Non-conformance may prevent the guidewire from passing through the introducer hub during a surgical procedure. The inability of the guidewire to pass through the introducer is due to the presence of voids in the internal lumen of the sheath 104 units
AngioDynamics, Inc. 510(k) number 2024-01-30 Class II Process control Non-conformance may prevent the guidewire from passing through the introducer hub during a surgical procedure. The inability of the guidewire to pass through the introducer is due to the presence of voids in the internal lumen of the sheath 4366 units
AngioDynamics, Inc. 510(k) number 2024-01-30 Class II Process control Non-conformance may prevent the guidewire from passing through the introducer hub during a surgical procedure. The inability of the guidewire to pass through the introducer is due to the presence of voids in the internal lumen of the sheath 959 units
AngioDynamics, Inc. 510(k) number 2024-01-30 Class II Process control Non-conformance may prevent the guidewire from passing through the introducer hub during a surgical procedure. The inability of the guidewire to pass through the introducer is due to the presence of voids in the internal lumen of the sheath 58 units
AngioDynamics, Inc. 510(k) number 2024-01-30 Class II Process control Non-conformance may prevent the guidewire from passing through the introducer hub during a surgical procedure. The inability of the guidewire to pass through the introducer is due to the presence of voids in the internal lumen of the sheath 1676 units
AngioDynamics, Inc. 510(k) number 2024-01-30 Class II Process control Non-conformance may prevent the guidewire from passing through the introducer hub during a surgical procedure. The inability of the guidewire to pass through the introducer is due to the presence of voids in the internal lumen of the sheath 5176 units
AngioDynamics, Inc. 510(k) number 2024-01-30 Class II Process control Non-conformance may prevent the guidewire from passing through the introducer hub during a surgical procedure. The inability of the guidewire to pass through the introducer is due to the presence of voids in the internal lumen of the sheath 15 units
AngioDynamics, Inc. 510(k) number 2024-01-30 Class II Process control Non-conformance may prevent the guidewire from passing through the introducer hub during a surgical procedure. The inability of the guidewire to pass through the introducer is due to the presence of voids in the internal lumen of the sheath 5840 units
AngioDynamics, Inc. 510(k) number 2024-01-30 Class II Process control Non-conformance may prevent the guidewire from passing through the introducer hub during a surgical procedure. The inability of the guidewire to pass through the introducer is due to the presence of voids in the internal lumen of the sheath 600 units
AngioDynamics, Inc. 510(k) number 2024-01-30 Class II Process control Non-conformance may prevent the guidewire from passing through the introducer hub during a surgical procedure. The inability of the guidewire to pass through the introducer is due to the presence of voids in the internal lumen of the sheath 130 units
AngioDynamics, Inc. 510(k) number 2024-01-30 Class II Process control Non-conformance may prevent the guidewire from passing through the introducer hub during a surgical procedure. The inability of the guidewire to pass through the introducer is due to the presence of voids in the internal lumen of the sheath 200 units
AngioDynamics, Inc. 510(k) number 2024-01-30 Class II Process control Non-conformance may prevent the guidewire from passing through the introducer hub during a surgical procedure. The inability of the guidewire to pass through the introducer is due to the presence of voids in the internal lumen of the sheath 155 units
AngioDynamics, Inc. 510(k) number 2024-01-30 Class II Process control Non-conformance may prevent the guidewire from passing through the introducer hub during a surgical procedure. The inability of the guidewire to pass through the introducer is due to the presence of voids in the internal lumen of the sheath 65 units
AngioDynamics, Inc. 510(k) number 2024-01-30 Class II Process control Non-conformance may prevent the guidewire from passing through the introducer hub during a surgical procedure. The inability of the guidewire to pass through the introducer is due to the presence of voids in the internal lumen of the sheath 40 units
AngioDynamics, Inc. 510(k) number 2024-01-30 Class II Process control Non-conformance may prevent the guidewire from passing through the introducer hub during a surgical procedure. The inability of the guidewire to pass through the introducer is due to the presence of voids in the internal lumen of the sheath 39 units

Recalls

The FDA has not published a severity grade for these. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2004-03-18 Not classified Other Product labeled at Vascular Dilator Set 5 Fr contains 5 dilators ranging from 6 Fr to 14 Fr. 43 units 2005-10-25

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.