Achieve Advance™

Achieve Advance is an intracardiac electrophysiology catheter that records atrial electrical signals and provides cardiac stimulation during electrophysiology studies. Its distal mapping…

Registry build 21.09.26

Achieve Advance is an intracardiac electrophysiology catheter that records atrial electrical signals and provides cardiac stimulation during electrophysiology studies. Its distal mapping section forms a circular loop with evenly spaced electrodes. The range includes pre-shaped loop diameters of 15, 20 and 25 mm.

The catheter is intended for multielectrode mapping, recording and stimulation only. It is delivered through a delivery catheter and has an effective length of 146 cm with a 3.3 Fr body. The 15 and 20 mm loop configurations have eight electrodes.

Listed Item

Catheter 2ACH20 20MM Diameter US

Body and Loop Materials

The distal body combines nitinol and Pebax, while the proximal section uses stainless steel and polyimide. The loop uses nitinol insulated with PET and covered with Pebax. These structural sections support the loop and electrode arrangement for obtaining atrial electrograms.

5manufacturers in China registered for this device type
3catalogue numbers in this listing
5510(k) clearances naming this product code
1recall

Who Else Makes It

Concentrated in Jiangsu (2), Tianjin (1), Shanghai (1). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code DRF
Manufacturer City Province Registered as Device types
Jiangyin Sinbon Electronics Co Ltd Jiangyin Jiangsu Contract manufacturer 13
Palconn Technology Co., Ltd. Shenzhen Guangdong Contract manufacturer 2
Steris Sterilization Technologies (Suzhou) Ltd Suzhou Jiangsu Contract manufacturer 44
Tianjin Ethylene Oxide Sterilization Technology Co., Ltd. Tianjin Tianjin Contract manufacturer 4
Shanghai Microport EP Medtech Co., Ltd. Shanghai Shanghai Manufacturer 3

Record

Regulatory record for Achieve Advance™
Listed by Medtronic, Inc., United States
FDA product code DRF
Device type Catheter, Electrode Recording, Or Probe, Electrode Recording
Device class Class 2
Regulation 21 CFR 870.1220
Establishment Specification developer, Repacker / relabeller, Manufacturer, Exporter
510(k) K162892
Record published 2016-12-26
Record revised 2024-10-28 (version 3)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number
Storage Special storage condition: Keep dry; Storage environment humidity up to 85 % RH; Special storage condition: Keep away from sunlight; Storage environment temperature 59 to 86 °F; Handling environment temperature -31 to 136 °F
Sizes Length 165 cm

Catalogue Numbers

Catalogue numbers for Achieve Advance™
Catalogue number Size Status
2ACH20 Catheter diameter 1.1 mm (3.3 Fr) In distribution
2ACH15 Length 165.0 cm In distribution
2ACH25 Length 165.0 cm In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Map-iT Access Point Medical, LLC 420
Woven Boston Scientific Corporation 126
Inquiry™ Irvine Biomedical. Inc. 122
Webster Biosense Webster, Inc. 121
Viking™ Boston Scientific Corporation 81
EasyFinder Fixed Curve Diagnostic Catheter Shanghai Microport EP Medtech Co., Ltd. 56
Supreme™ St. Jude Medical Cardiovascular Division 55
Celsius Biosense Webster, Inc. 47
Response™ St. Jude Medical Cardiovascular Division 46
Torqr™ Medtronic, Inc. 32
Catheter, Electrode Recording, Or Probe, Electrode Recording Medtronic, Inc. 27
Lasso NAV Biosense Webster, Inc. 22

Showing 12 of 112. All products under Catheter, Electrode Recording, Or Probe, Electrode Recording

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K233397 2023-12-02
K190132 2019-07-30
K183547 2019-07-30
K162892 2016-11-15
K153139 2016-05-06

Recalls

1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2015-09-29 Class II Under Investigation by firm 64 units of Achieve Electrical Cables were shipped with a potential sterility breach. 64 units 2016-03-09

PMA Approvals

A premarket approval is the full Class III route, granted on clinical evidence rather than on equivalence to an existing device. It is the highest regulatory bar a device of this type can clear.

FDA premarket approvals naming this product code
PMA number Decision Trade name Approved to
P950005 2001-10-05 CELSIUS DIAGNOSTIC/ABLATION DEFLECTABLE TIP CATHETER Biosense Webster, Inc.

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer