Carescape B450
Carescape B450 MBA323 (ATO Model)
10manufacturers in China registered for this device type
1catalogue number
Who Else Makes It
Concentrated in Guangdong (6), Jiangsu (1), Hebei (1). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Amphenol Medical Technologies (Dongguan) Co., Ltd. | Dongguan | Guangdong | Contract manufacturer | 77 |
| Linxens Healthcare (Tianjin) Co., Ltd. | Jinnan District | Tianjin | Contract manufacturer | 7 |
| Shenzhen Mindray BIO-Medical Electronics Co., Ltd. | Shenzhen | Guangdong | Specification developer | 61 |
| GE Medical Systems (China) Co., Ltd. | Wuxi | Jiangsu | Contract manufacturer | 57 |
| Edan Instruments, Inc. | Shenzhen | Guangdong | Contract manufacturer | 56 |
| Orantech Inc. | Shenzhen | Guangdong | Contract manufacturer | 40 |
| Shenzhen Comen Medical Instruments Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 24 |
| Contec Medical Systems Co., Ltd. | Qinhuangdao | Hebei | Manufacturer | 22 |
| Guangdong Biolight Meditech Co., Ltd. | Zhuhai | Guangdong | Manufacturer | 19 |
| Shandong Corecare Technology Limited | Jinan | Shandong | Manufacturer | 2 |
Record
| Listed by | GE Healthcare Finland OY, Finland |
|---|---|
| FDA product code | DSI |
| Device type | Detector And Alarm, Arrhythmia |
| Device class | Class 2 |
| Regulation | 21 CFR 870.1025 |
| Establishment | Specification developer, Repacker / relabeller, Manufacturer |
| 510(k) | K213363 |
| Record published | 2022-05-13 |
Specifications
| MRI safety | MR Unsafe |
|---|---|
| Label carries | manufacturing date, serial number |
| Storage | Handling environment humidity 10 to 90 % RH; Storage environment humidity 10 to 90 % RH; Handling environment temperature 10 to 40 °C; Storage environment temperature -20 to 60 °C; Handling environment atmospheric pressure 70 to 106 KiloPascal; Storage environment atmospheric pressure 50 to 106 KiloPascal |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| MBA323 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Trulink | Spacelabs Healthcare (Washington), Inc | 160 |
| Fukuda Denshi | Fukuda Denshi Co., Ltd. | 30 |
| Q-Tel RMS | Mortara Instrument, Inc. | 20 |
| Detector And Alarm, Arrhythmia | Philips Medical Systems Hsg | 20 |
| ECG Electrodes | Philips Medical Systems Hsg | 19 |
| Seeq™ | Medtronic, Inc. | 18 |
| Life Sensing Instruments, Inc. | Life Sensing Instruments, Inc. | 17 |
| NIBP Cuffs | Philips Medical Systems Hsg | 14 |
| Waveline EZ+ | Avante | 11 |
| BodyGuardian | Preventice Technologies, Inc. | 10 |
| BodyGuardian Kit | Preventice Technologies, Inc. | 8 |
| Waveline Pro+ | Avante | 7 |
Showing 12 of 112. All products under Detector And Alarm, Arrhythmia
Recalls Naming This Product
1 recall names this product by its own identifier, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|---|---|
| GE Healthcare Finland OY | 510(k) number | 2025-09-26 | Class II | Component change control | Potential loss of monitoring on affected monitors when powered by certain batteries. Affected batteries can lose capability to hold charge and provide back up power. If this situation occurs, it will cause loss of patient monitoring and pot | 3271 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.