Carescape Central Station

Carescape Central Station V2 MAI 700 ATO Model

Registry build 21.09.26
10manufacturers in China registered for this device type
2catalogue numbers in this listing
2510(k) clearances naming this product code
1recall

Who Else Makes It

Concentrated in Guangdong (6), Jiangsu (1), Hebei (1). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code DSI
Manufacturer City Province Registered as Device types
Amphenol Medical Technologies (Dongguan) Co., Ltd. Dongguan Guangdong Contract manufacturer 77
Linxens Healthcare (Tianjin) Co., Ltd. Jinnan District Tianjin Contract manufacturer 7
Shenzhen Mindray BIO-Medical Electronics Co., Ltd. Shenzhen Guangdong Specification developer 61
GE Medical Systems (China) Co., Ltd. Wuxi Jiangsu Contract manufacturer 57
Edan Instruments, Inc. Shenzhen Guangdong Contract manufacturer 56
Orantech Inc. Shenzhen Guangdong Contract manufacturer 40
Shenzhen Comen Medical Instruments Co., Ltd. Shenzhen Guangdong Contract manufacturer 24
Contec Medical Systems Co., Ltd. Qinhuangdao Hebei Manufacturer 22
Guangdong Biolight Meditech Co., Ltd. Zhuhai Guangdong Manufacturer 19
Shandong Corecare Technology Limited Jinan Shandong Manufacturer 2

Record

Regulatory record for Carescape Central Station
Listed by GE Medical Systems Information Technologies, Inc., United States
FDA product code DSI
Device type Detector And Alarm, Arrhythmia
Device class Class 2
Regulation 21 CFR 870.1025
Establishment Specification developer, Repacker / relabeller, Manufacturer
510(k) K162012
Record published 2017-02-11
Record revised 2025-04-22 (version 6)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only
Label carries manufacturing date, serial number
Storage Storage environment temperature -40 to 70 °C; Storage environment humidity 5 to 95 % RH; Storage environment atmospheric pressure 500 to 1075 KiloPascal
Distribution end date 2022-12-31

Catalogue Numbers

Catalogue numbers for Carescape Central Station
Catalogue number Size Status
V2 Integrated MAI 700 Withdrawn
V2 Standard MAS 700 Withdrawn

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Trulink Spacelabs Healthcare (Washington), Inc 160
Fukuda Denshi Fukuda Denshi Co., Ltd. 30
Q-Tel RMS Mortara Instrument, Inc. 20
Detector And Alarm, Arrhythmia Philips Medical Systems Hsg 20
ECG Electrodes Philips Medical Systems Hsg 19
Seeq™ Medtronic, Inc. 18
Life Sensing Instruments, Inc. Life Sensing Instruments, Inc. 17
NIBP Cuffs Philips Medical Systems Hsg 14
Waveline EZ+ Avante 11
BodyGuardian Preventice Technologies, Inc. 10
BodyGuardian Kit Preventice Technologies, Inc. 8
Waveline Pro+ Avante 7

Showing 12 of 112. All products under Detector And Alarm, Arrhythmia

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K062976 2007-03-16
K032370 2003-08-13

Recalls Naming This Product

6 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of Carescape Central Station
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
GE Medical Systems Information Technologies, Inc. 510(k) number 2026-07-30 Not classified Under Investigation by firm Device may not resume patient monitoring for at least 3 minutes following system restart. Issue can lead to potential delay in recognition of clinically significant events. 29,570 (23,632 US; 5,938 OUS)
Wipro GE Healthcare Private Ltd. 510(k) number 2025-09-05 Class II Software design Carescape Central Station (CSCS), software version V3.0.5, can cause the system to enter a continuous reboot cycle. If this occurs, a loss of central monitoring of connected patients could result. This issue occurs only when the number of c 173 units
Wipro GE Healthcare Private Ltd. 510(k) number 2025-09-05 Class II Software design Carescape Central Station (CSCS), software version V3.0.5, can cause the system to enter a continuous reboot cycle. If this occurs, a loss of central monitoring of connected patients could result. This issue occurs only when the number of c 2365 units
GE Medical Systems, LLC 510(k) number 2022-05-10 Class II Process control The CARESAPE Central Station (CSCS) V2 can shut down due to a potential power supply component failure. This can lead to loss of patient monitoring at the central station. 30,993 Central Stations and 2,180 FRUs and displays
GE Medical Systems, LLC 510(k) number 2022-01-28 Class II Software design If the CARESCAPE Central Station v2.0 is used with an unapproved keyboard, the audio can be muted resulting in loss of audible alarms. 10,445 units
GE Medical Systems Information Technologies, Inc. 510(k) number 2018-01-11 Class II Software in the Use Environment CARESCAPE Central Station (CSCS) software version 2.0.2 units may experience unexpected NO COMM (No Communication) and network communication issues after boot-up or system restart. 1803 units 2021-07-07

Recalls

1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity
2025-04-25 Class II Software design The MUSE Administrator Account active directory or local credential could potentially be used from your local network to log into a GE HealthCare MUSE 5 system and potentially manipulate recorded patient data. 4,277 systems

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer