Detector and Alarm, Arrhythmia
Catalogue number 2040427-002, listed by GE Healthcare Finland OY, Finland, under Detector And Alarm, Arrhythmia. 10 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Guangdong (6), Jiangsu (1), Hebei (1). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Amphenol Medical Technologies (Dongguan) Co., Ltd. | Dongguan | Guangdong | Contract manufacturer | 77 |
| Linxens Healthcare (Tianjin) Co., Ltd. | Jinnan District | Tianjin | Contract manufacturer | 7 |
| Shenzhen Mindray BIO-Medical Electronics Co., Ltd. | Shenzhen | Guangdong | Specification developer | 61 |
| GE Medical Systems (China) Co., Ltd. | Wuxi | Jiangsu | Contract manufacturer | 57 |
| Edan Instruments, Inc. | Shenzhen | Guangdong | Contract manufacturer | 56 |
| Orantech Inc. | Shenzhen | Guangdong | Contract manufacturer | 40 |
| Shenzhen Comen Medical Instruments Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 24 |
| Contec Medical Systems Co., Ltd. | Qinhuangdao | Hebei | Manufacturer | 22 |
| Guangdong Biolight Meditech Co., Ltd. | Zhuhai | Guangdong | Manufacturer | 19 |
| Shandong Corecare Technology Limited | Jinan | Shandong | Manufacturer | 2 |
Record
| Listed by | GE Healthcare Finland OY, Finland |
|---|---|
| FDA product code | DSI |
| Device type | Detector And Alarm, Arrhythmia |
| Device class | Class 2 |
| Regulation | 21 CFR 870.1025 |
| Establishment | Specification developer, Repacker / relabeller, Manufacturer |
| 510(k) | K131414 |
| Record published | 2016-07-22 |
| Record revised | 2018-07-06 (version 3) |
Specifications
| MRI safety | MR Unsafe |
|---|---|
| Prescription | Prescription only |
| Label carries | lot or batch number |
| Storage | Handling environment atmospheric pressure 70 to 106 KiloPascal; Storage environment atmospheric pressure 50 to 106 KiloPascal; Handling environment temperature 10 to 35 °C; Handling environment humidity 15 to 90 % RH; Storage environment temperature -20 to 60 °C; Storage environment humidity 10 to 90 % RH |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 2040427-002 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Trulink | Spacelabs Healthcare (Washington), Inc | 160 |
| Fukuda Denshi | Fukuda Denshi Co., Ltd. | 30 |
| Q-Tel RMS | Mortara Instrument, Inc. | 20 |
| Detector And Alarm, Arrhythmia | Philips Medical Systems Hsg | 20 |
| ECG Electrodes | Philips Medical Systems Hsg | 19 |
| Seeq™ | Medtronic, Inc. | 18 |
| Life Sensing Instruments, Inc. | Life Sensing Instruments, Inc. | 17 |
| NIBP Cuffs | Philips Medical Systems Hsg | 14 |
| Waveline EZ+ | Avante | 11 |
| BodyGuardian | Preventice Technologies, Inc. | 10 |
| BodyGuardian Kit | Preventice Technologies, Inc. | 8 |
| Waveline Pro+ | Avante | 7 |
Showing 12 of 112. All products under Detector And Alarm, Arrhythmia
Recalls Naming This Product
3 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| GE Medical Systems, LLC | 510(k) number | 2015-05-04 | Class II | Software design | The heart rate could be calculated from pacer pulses without indication that pacemaker detection is OFF in some combinations of Bx50 monitors, a PDM, and CIC/CSCS. Then the monitor does not show the Pacer Off message and there may not be an | 110 (83 units US, 27 units OUS) | 2015-09-15 |
| GE Medical Systems, LLC | 510(k) number | 2014-06-13 | Class II | Software design | Partial loss of monitoring with the CARESCAPE Monitor B850, B650 or B450. When connecting the PDM (Patient Data Module) to the CARESCAPE B850, B650 or B450 monitor with software version 2 the PDM may not start communicating to the monitor | 41,992 (20,509 US; 21,483 OUS) | 2016-09-07 |
| GE Medical Systems, LLC | 510(k) number | 2014-02-28 | Class II | Software design | GE Healthcare has recently become aware of potential safety issues associated with the CARESCAPE Monitor B850 and CARESCAPE Monitor B650. These issues include both NIBP (Non-Invasive Blood Pressure) and Bed to Bed Issues. | 676 units OUS | 2015-04-29 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.