Reveal Linq™

MON LNQ11 Reveal Linq USA FW2.0

Registry build 21.09.26
10manufacturers in China registered for this device type
5catalogue numbers in this listing
6510(k) clearances naming this product code
1recall

Who Else Makes It

Concentrated in Guangdong (6), Jiangsu (1), Hebei (1). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code DSI
Manufacturer City Province Registered as Device types
Amphenol Medical Technologies (Dongguan) Co., Ltd. Dongguan Guangdong Contract manufacturer 77
Linxens Healthcare (Tianjin) Co., Ltd. Jinnan District Tianjin Contract manufacturer 7
Shenzhen Mindray BIO-Medical Electronics Co., Ltd. Shenzhen Guangdong Specification developer 61
GE Medical Systems (China) Co., Ltd. Wuxi Jiangsu Contract manufacturer 57
Edan Instruments, Inc. Shenzhen Guangdong Contract manufacturer 56
Orantech Inc. Shenzhen Guangdong Contract manufacturer 40
Shenzhen Comen Medical Instruments Co., Ltd. Shenzhen Guangdong Contract manufacturer 24
Contec Medical Systems Co., Ltd. Qinhuangdao Hebei Manufacturer 22
Guangdong Biolight Meditech Co., Ltd. Zhuhai Guangdong Manufacturer 19
Shandong Corecare Technology Limited Jinan Shandong Manufacturer 2

Record

Regulatory record for Reveal Linq™
Listed by Medtronic, Inc., United States
FDA product code DSI
Device type Detector And Alarm, Arrhythmia
Device class Class 2
Regulation 21 CFR 870.1025
Establishment Specification developer, Repacker / relabeller, Manufacturer, Exporter
510(k) K212008
Record published 2021-09-04
Record revised 2023-08-14 (version 6)

Specifications

Specifications
MRI safety MR Conditional
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries serial number
Storage Handling environment temperature -18 to 55 °C; Storage environment temperature 15 to 30 °C; Storage environment humidity 15 to 93 % RH
Distribution end date 2023-08-10

Catalogue Numbers

Catalogue numbers for Reveal Linq™
Catalogue number Size Status
LNQ11 In distribution
LNQ11 In distribution
LNQ11 In distribution
LNQ11 Withdrawn
LNQ11 Withdrawn

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Trulink Spacelabs Healthcare (Washington), Inc 160
Fukuda Denshi Fukuda Denshi Co., Ltd. 30
Q-Tel RMS Mortara Instrument, Inc. 20
Detector And Alarm, Arrhythmia Philips Medical Systems Hsg 20
ECG Electrodes Philips Medical Systems Hsg 19
Seeq™ Medtronic, Inc. 18
Life Sensing Instruments, Inc. Life Sensing Instruments, Inc. 17
NIBP Cuffs Philips Medical Systems Hsg 14
Waveline EZ+ Avante 11
BodyGuardian Preventice Technologies, Inc. 10
BodyGuardian Kit Preventice Technologies, Inc. 8
Waveline Pro+ Avante 7

Showing 12 of 112. All products under Detector And Alarm, Arrhythmia

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K190574 2019-09-24
K150117 2015-05-27
K103764 2011-05-04
K082475 2008-11-07
K071641 2007-11-21
K071655 2007-11-21

Recalls Naming This Product

1 recall names this product by its own identifier, the 510(k) it is cleared under.

Recalls naming the identifiers of Reveal Linq™
Recalled by Identified by Initiated FDA class Root cause Reason Quantity
Medtronic, Inc. 510(k) number 2021-06-01 Class II Software design Reveal LINQ with TruRhythm ICMs, that undergo a partial electrical reset appear to be programmed “ON”, but are no longer able to detect and report Brady and Pause events to clinicians. 666210 devices

Recalls

1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2016-02-23 Class II Software design Medtronic has identified an issue with the sensitivity of an algorithm used in the Reveal LINQ ICM that may prematurely trigger the Recommended Replacement Time (RRT) alert in some devices. Battery capacity is not affected and the device wi 189,009 2017-09-25

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer