Waveline EZ-MAX
5 catalogue numbers from 60145T10ICO2, listed by Avante, under Detector And Alarm, Arrhythmia. 10 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Guangdong (6), Jiangsu (1), Hebei (1). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Amphenol Medical Technologies (Dongguan) Co., Ltd. | Dongguan | Guangdong | Contract manufacturer | 77 |
| Linxens Healthcare (Tianjin) Co., Ltd. | Jinnan District | Tianjin | Contract manufacturer | 7 |
| Shenzhen Mindray BIO-Medical Electronics Co., Ltd. | Shenzhen | Guangdong | Specification developer | 61 |
| GE Medical Systems (China) Co., Ltd. | Wuxi | Jiangsu | Contract manufacturer | 57 |
| Edan Instruments, Inc. | Shenzhen | Guangdong | Contract manufacturer | 56 |
| Orantech Inc. | Shenzhen | Guangdong | Contract manufacturer | 40 |
| Shenzhen Comen Medical Instruments Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 24 |
| Contec Medical Systems Co., Ltd. | Qinhuangdao | Hebei | Manufacturer | 22 |
| Guangdong Biolight Meditech Co., Ltd. | Zhuhai | Guangdong | Manufacturer | 19 |
| Shandong Corecare Technology Limited | Jinan | Shandong | Manufacturer | 2 |
Record
| Listed by | Avante |
|---|---|
| FDA product code | DSI |
| Device type | Detector And Alarm, Arrhythmia |
| Device class | Class 2 |
| Regulation | 21 CFR 870.1025 |
| 510(k) | K131971 |
| Record published | 2016-09-23 |
| Record revised | 2021-11-10 (version 7) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Label carries | manufacturing date, serial number |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 60145T10ICO2 | In distribution | |
| 60145T10NTS | In distribution | |
| 60145T10RCO2 | In distribution | |
| 60145T10I | In distribution | |
| 60145T10 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Trulink | Spacelabs Healthcare (Washington), Inc | 160 |
| Fukuda Denshi | Fukuda Denshi Co., Ltd. | 30 |
| Q-Tel RMS | Mortara Instrument, Inc. | 20 |
| Detector And Alarm, Arrhythmia | Philips Medical Systems Hsg | 20 |
| ECG Electrodes | Philips Medical Systems Hsg | 19 |
| Seeq™ | Medtronic, Inc. | 18 |
| Life Sensing Instruments, Inc. | Life Sensing Instruments, Inc. | 17 |
| NIBP Cuffs | Philips Medical Systems Hsg | 14 |
| Waveline EZ+ | Avante | 11 |
| BodyGuardian | Preventice Technologies, Inc. | 10 |
| BodyGuardian Kit | Preventice Technologies, Inc. | 8 |
| Waveline Pro+ | Avante | 7 |
Showing 12 of 112. All products under Detector And Alarm, Arrhythmia
Recalls Naming This Product
2 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Edan Diagnostics, Inc. | 510(k) number | 2025-10-24 | Class II | Device Design | As a result of receiving an FDA It Has Come to Our Attention Letter (IHCTOA Letter) regarding potential cybersecurity issues with various of the firm device. | 14550 | |
| Edan Diagnostics, Inc. | 510(k) number | 2016-06-23 | Class II | Nonconforming Material/Component | Incorrect CO2 readings with some patient monitors. | 521 | 2016-11-16 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.